Effective volume of rebreathed air during breathing with facepieces increases with protection class and decreases with ambient airflow
Authors:
Open Access
- 21 March 2024
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (3) , e0299919
Abstract
Wearing facepieces is discussed in the context of increasing the volume of rebreathed air. We hypothesized that rebreathed air volume increases with increasing filtering facepiece (FFP) class and that persons breathing via facepieces compensate for the additional dead-space. We have determined the effective amount of rebreathed air for a surgical masks and FFP2 and FFP3 respirators in a physical model and determined tidal volumes, breathing frequency, blood oxygen saturation, and transcutaneously measured blood carbon dioxide partial pressure (PCO2) in lung-healthy subjects breathing without and with facepieces at rest and during exercising on a recumbent ergometer. Rebreathed air volume increased with the facepieces’ protection class and with increasing inspiration volume by 45 ± 2 ml to 247 ± 1 ml. Ambient airflow reduced rebreathed air volume by 17% up to 100% (all p < 0.001). When wearing facepieces, subjects increased tidal volume (p < 0.001) but not breathing frequency. Oxygen saturation was not influenced by facepieces. With FFP3 respirators PCO2 increased by up to 3.2 mmHg (p < 0.001) at rest but only up to 1.4 mmHg (p < 0.001) when exercising. Discomfort of breathing increased with increasing protection class of the facepiece but was consistently perceived as tolerable. We conclude that the amount of rebreathed air increases with increasing protection class of facepieces. Healthy adults were capable to compensate the facepieces’ dead-space by adapting tidal volume at rest and during physical activity; thereby they tolerated moderate increases in PCO2. Ambient airflow may considerably reduce the amount of facepiece related rebreathed air.Keywords
This publication has 24 references indexed in Scilit:
- Air seal performance of personalized and statistically shaped 3D-printed face masks compared with market-available surgical and FFP2 masksScientific Reports, 2021
- The effects of warmth and CO 2 concentration, with and without bioeffluents, on the emission of CO 2 by occupants and physiological responsesIndoor Air, 2021
- Assessment of Respiratory Function in Infants and Young Children Wearing Face Masks During the COVID-19 PandemicJAMA Network Open, 2021
- Effects of surgical and FFP2/N95 face masks on cardiopulmonary exercise capacityClinical Research in Cardiology, 2020
- Effect of occupant-induced indoor CO2 concentration and bioeffluents on human physiology using a spirometric testBuilding and Environment, 2019
- Physiological responses during exposure to carbon dioxide and bioeffluents at levels typically occurring indoorsIndoor Air, 2016
- Pulmonary and heart rate responses to wearing N95 filtering facepiece respiratorsAmerican Journal of Infection Control, 2013
- Absence of consequential changes in physiological, thermal and subjective responses from wearing a surgical maskRespiratory Physiology & Neurobiology, 2012
- Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomographyActa Anaesthesiologica Scandinavica, 2011
- Evaluation of transcutaneous CO2 responses following acute changes in PaCO2 in healthy subjectsRespirology, 2009