SSStefan Schumann

Stefan Schumann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefan Schumann has a total of 328 co-authors. Here are the top co-authors by number of shared publications:

  • J Guttmann

    University Medical Center Freiburg, Germany

    43 shared publications
  • Josef Guttmann

    Division of Experimental Anesthesiology, Department of Anesthesiology and Intensive Care Medicine, University Medical Center, Freiburg, Germany

    31 shared publications
  • Steffen Wirth

    Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany

    28 shared publications
  • K Möller

    Furtwangen University, VS-Schwenningen, Germany

    16 shared publications
  • C Stahl

    Anästhesiologische Universitätsklinik, Freiburg, Germany

    12 shared publications
  • J. Guttmann

    Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg im Breisgau, Germany

    12 shared publications

Latest Publications

  • Design and development of a novel media-separated valve for flow-controlled expiration during mechanical ventilation

    by Patryk Dzierzawski, Bernd Flamm, Benedikt Fischer, Hartmut Breger, Martin Huth, Sashko Spassov, Christin Wenzel, Stefan Schumann, Sara Lozano-Zahonero

    Mechanical ventilation has become a central therapeutic means in modern medicine. However, mechanical ventilation carries the risk of ventilator-induced lung injury. Our group introduced flow-controlled expiration (FLEX) as an additional approach to effective, lung-protective mechanical ventilation. By gradually reducing the pneumatic resistance, FLEX controls expiratory flow toward a user-set constant target, replacing the exponential flow-time profile of a conventional expiration. Primarily developed to demonstrate the physiological concept, the initial FLEX-system prototype did not provide closed-loop flow regulation and full media separation. These considerations motivated the development of a more advanced system that precisely adjusts pneumatic resistance to achieve rapid closed-loop control of the desired expiratory flow rates. We validated our system through multiple tests using physical lung surrogates. We could effectively control the expiratory flow with two ventilation devices. We thereby demonstrated that the system attenuated high initial expiratory peak flow and guided expiratory flow toward user-selected target values in physical respiratory-system models under a range of physiological and non-physiological conditions. Our system features an innovative valve that enables accurate flow regulation, facilitates easy valve replacement, and ensures complete separation of the respiratory gas space from the ambient environment, thereby enhancing safety and reliability. Moreover, the microcontroller implementation creates a self-contained system, making it well-suited for potential clinical applications.

  • Open Access

    A ventilatable physical four compartment model of the rat thorax for electrical impedance tomography

    by Silke Borgmann, Alaa Aldin Koussa, Lea Kuhn, Stefan Schumann

    Objective. Electrical impedance tomography (EIT) has become an important means for gaining enhanced insights into respiratory system mechanics, particularly in research on the conditions of the lungs during mechanical ventilation. For further development of EIT based research regarding the respiratory system, animal experiments play a crucial role. Approach. Focussing on reduction of small animal experiments, we built a physical EIT model of the rat thorax for potential setup development and standardised algorithm testing. The model contains four separately ventilatable compartments, aiming to represent ventilation in the ventral-right, ventral-left, dorsal-right and dorsal-left regions of interest (ROI) of the EIT image. The model was connected to an EIT device and ventilated with a variety of tidal volumes and respiratory rates with all combinations of connected compartments. Thereby, airway pressure and flow were measured to determine the mechanical properties of the physical model. Main results. EIT measurements confirmed the localisation of the four compartments in the desired ROI and connecting/disconnecting individual compartments ventilation resulted in corresponding changes in the regional tidal impedance variation. The physical model had a compliance of 146 ± 5 μ l/cmH 2 O when four compartments were ventilated at a respiratory rate of 30 1 min −1 . Respiratory system compliance decreased when ventilation was restricted to fewer ventilated compartments. The compliance was comparable for all tested tidal volumes but decreased with increasing respiratory rate. Significance. We present a ventilatable four compartment EIT model of the rat thorax that is capable of simulating regional ventilation. The respiratory system mechanics of the model reflect mechanics comparable to mechanically ventilated lung injured rats including viscoelastic behaviour, as indicated by the dependency of respiratory system compliance on respiratory rate. While this model is not a substitute for in vivo pathophysiological studies, it may be useful for reducing small animal experiments when testing setups or experimental procedures, and may further allow to generate reproducible data for standardised algorithm testing.

  • Open Access

    Approaching volume status via electrical impedance tomography—an explorative study in healthy volunteers*

    by Sophie Wölbert, Johannes Hell, Stefan Schumann

    Objective. Monitoring the volume status of patients remains a fundamentally unresolved issue in the perioperative setting but also in intensive care medicine. Electrical impedance tomography (EIT) enables noninvasive and radiation-free functional imaging of impedance changes of a cross-sectional plane of the thorax. Approach. We hypothesized that cardiac-induced impedance fluctuations in the EIT signal contain information about the global volume status. Therefore, we recorded EIT signals from 24 healthy volunteers before and up to 100 min after ingestion of 750 ml liquid following more than nine hours fluid restriction. We isolated a characteristic cardiac-induced impedance profile from the global impedance curve and compared its characteristics to measures of non-invasive hemodynamic monitoring and the diameter of the vena cava inferior (VCI) determined via ultrasonography. Main results. The diameter of the VCI, mean arterial pressure and stroke volume index, did not change systematically after liquid ingestion. Heart rate was increased 20 min after, and heart rate variability was increased immediately after liquid ingestion. The amplitude, the area under the curve and gradients of its rise and decline of the characteristic cardiac-induced impedance profile changed 60 min after liquid ingestion. Significance. Cardiac-induced pulsatile signals in EIT recordings changed characteristically after liquid ingestion, loosely corresponding with changes in heart rate and heart rate variability. These signals may contain valuable information about the general volume status and may be utilized for enhanced monitoring of a patient’s volume status.


  • Open Access

    Impact of preoperative audiovisual distraction on emergence agitation in patients undergoing orthognathic surgery: a prospective, randomized, single-blinded pilot study

    by Matthias Jakob Posch, Susanne Fiebig-Widmann, Marc Christian Metzger, Hartmut Buerkle, Stefan Schumann, Christian Ingo Schwer

    Posch MJ, et al. J Dent Anesth Pain Med. 2025 Dec;25(6):399-408. https://doi.org/10.17245/jdapm.2025.25.6.399


  • Open Access

    Efficiency of passive activated carbon anaesthetic gas capturing systems during simulated ventilation

    by Christin Wenzel, Bernd Flamm, Torsten Loop, Stefan Schumann, Johannes Spaeth


  • Open Access

    Comparison of Force Distribution during Laryngoscopy with the C-MAC D-BLADE and Macintosh-Style Blades: A Randomised Controlled Clinical Trial

    by Axel Schmutz, Ingo Breddin, Ramona Draxler, Stefan Schumann, Johannes Spaeth

    Background: The geometry of a laryngoscope’s blade determines the forces acting on the pharyngeal structures to a relevant degree. Knowledge about the force distribution along the blade may prospectively allow for the development of less traumatic blades. Therefore, we examined the forces along the blades experienced during laryngoscopy with the C-MAC D-BLADE and blades of the Macintosh style. We hypothesised that lower peak forces are applied to the patient’s pharyngeal tissue during videolaryngoscopy with a C-MAC D-BLADE compared to videolaryngoscopy with a C-MAC Macintosh-style blade and direct laryngoscopy with a Macintosh-style blade. Beyond that, we assumed that the distribution of forces along the blade differs depending on the respective blade’s geometry. Methods: After ethical approval, videolaryngoscopy with the D-BLADE or the Macintosh blade, or direct laryngoscopy with the Macintosh blade (all KARL STORZ, Tuttlingen, Germany), was performed on 164 randomly assigned patients. Forces were measured at six positions along each blade and compared with regard to mean force, peak force and spatial distribution. Furthermore, the duration of the laryngoscopy was measured. Results: Mean forces (all p < 0.011) and peak forces at each sensor position (all p < 0.019) were the lowest with the D-BLADE, whereas there were no differences between videolaryngoscopy and direct laryngoscopy with the Macintosh blades (all p > 0.128). With the D-BLADE, the forces were highest at the blade’s tip. In contrast, the forces were more evenly distributed along the Macintosh blades. Videolaryngoscopy took the longest with the D-BLADE (p = 0.007). Conclusions: Laryngoscopy with the D-BLADE resulted in significantly lower forces acting on pharyngeal and laryngeal tissue compared to Macintosh-style blades. Interestingly, with the Macintosh blades, we found no advantage for videolaryngoscopy in terms of force application.


  • Open Access

    Effective volume of rebreathed air during breathing with facepieces increases with protection class and decreases with ambient airflow

    by Helen Ngo, Johannes Spaeth, Stefan Schumann

    Wearing facepieces is discussed in the context of increasing the volume of rebreathed air. We hypothesized that rebreathed air volume increases with increasing filtering facepiece (FFP) class and that persons breathing via facepieces compensate for the additional dead-space. We have determined the effective amount of rebreathed air for a surgical masks and FFP2 and FFP3 respirators in a physical model and determined tidal volumes, breathing frequency, blood oxygen saturation, and transcutaneously measured blood carbon dioxide partial pressure (PCO2) in lung-healthy subjects breathing without and with facepieces at rest and during exercising on a recumbent ergometer. Rebreathed air volume increased with the facepieces’ protection class and with increasing inspiration volume by 45 ± 2 ml to 247 ± 1 ml. Ambient airflow reduced rebreathed air volume by 17% up to 100% (all p < 0.001). When wearing facepieces, subjects increased tidal volume (p < 0.001) but not breathing frequency. Oxygen saturation was not influenced by facepieces. With FFP3 respirators PCO2 increased by up to 3.2 mmHg (p < 0.001) at rest but only up to 1.4 mmHg (p < 0.001) when exercising. Discomfort of breathing increased with increasing protection class of the facepiece but was consistently perceived as tolerable. We conclude that the amount of rebreathed air increases with increasing protection class of facepieces. Healthy adults were capable to compensate the facepieces’ dead-space by adapting tidal volume at rest and during physical activity; thereby they tolerated moderate increases in PCO2. Ambient airflow may considerably reduce the amount of facepiece related rebreathed air.


  • Open Access

    Reply to: Eye-tracking as a tool to evaluate defibrillator handling

    by Stefan Schumann, Axel Schmutz, Kim Feger, Johannes Spaeth

  • Open Access

    Comparative usability of manual defibrillators – A human factors study

    by Stefan Schumann, Axel Schmutz, Kim Feger, Johannes Spaeth


  • Intratidal compliance of the lung and the total respiratory system

    by Patryk Dzierzawski, Jakob Oswalt, Steffen Wirth, Stefan Schumann

    Objective. The worldwide rising quantity of surgeries and the corresponding need of mechanical ventilation means a rising number of patients are at risk of suffering from post-operative pulmonary complications. To prevent this risk, individual mechanics of the lung should be considered when setting the parameters of mechanical ventilation. Intratidal compliance analysis based on transpulmonal pressure would provide an estimate for individual lung mechanics. The downside of such measure, however, is its invasiveness. Accurate measurement requires recording of the esophageal pressure as surrogate for the actual pleural pressure. Measuring pressure at the airway opening is considerably easier, but the resulting mechanics of the respiratory system may not represent the actual lung mechanics in a straightforward fashion. Approach. In order to evaluate if the mechanics of the lungs are represented by analysis of the mechanics of the respiratory system we determined intratidal dynamic compliance-volume profiles of both in 23 lung-healthy mechanically ventilated patients undergoing elective surgery. We also compared the accuracy of the compliance profiles resulting from analysis of the total breath with those resulting from the analysis of inspiration data only. Main results. When the whole breath was analyzed 54.3%, and with only inspiration data 69.6%, of compliance profiles of the respiratory system matched those of the lung. With both approaches profiles of the lung and the respiratory system matched or deviated by only one neighboring step (75% whole breath, 91.3% inspiration only), and never contradicted each other. Significance. Compliance profiles calculated from volume and pressure data of the respiratory system are an adequate surrogate for the compliance profiles of the lungs of lung-healthy patients. Therefore, invasive assessment of esophageal pressure for achievement of intrapleural pressure is unnecessary. The compliance profiles based on only inspiratory data appear more sensitive for indicating intratidal derecruitment than those based on data of the whole breath.