A Metric for Quantifying the Resolution of Molecular Assays
Preprint
Abstract
Many assay developers focus on limit of detection (LOD) as a primary performance metric, and LOD is indeed useful for assays designed to determine the presence or absence of an analyte. However, LOD is less useful for ‘continuous assays’ designed to discriminate between concentrations of an analyte— e . g ., glucose monitoring in diabetes, where clinical care is guided by particular concentration ranges and thresholds. In such scenarios, it would be valuable to quantify discriminatory resolution— i . e ., whether an assay can differentiate 1 pM from 10 pM— but no such standardized metric currently exists. Here, we propose a useful solution, termed ‘resolution of molecular concentration’ (RMC). RMC offers a simple means for characterizing quantitative resolution and quickly comparing the quantitative performance of assays. By raising awareness of the limitations of current metrics for evaluating assay performance, we hope to empower the molecular diagnostics community to evaluate their methods in a more application-appropriate manner.Keywords
This publication has 9 references indexed in Scilit:
- Evaluation of Two Point of Care Technologies for Measuring Monoclonal Antibody Therapeutic-Aconcentrations in BloodBioanalysis, 2020
- The determination and interpretation of the therapeutic index in drug developmentNature Reviews Drug Discovery, 2012
- Hook Effect: A Pitfall Leading to Misdiagnosis of Hypoaldosteronism in an Infant with PseudohypoaldosteronismHormone Research in Paediatrics, 2010
- Dissociation of Pentameric to Monomeric C-Reactive Protein on Activated Platelets Localizes Inflammation to Atherosclerotic PlaquesCirculation Research, 2009
- Comparison of C-Reactive Protein and Low-Density Lipoprotein Cholesterol Levels in the Prediction of First Cardiovascular EventsNew England Journal of Medicine, 2002
- C-reactive protein: a valuable marker of sepsisIntensive Care Medicine, 2002
- Nomenclature in evaluation of analytical methods including detection and quantification capabilities1Adapted from the International Union of Pure and Applied Chemistry (IUPAC) document “Nomenclature in Evaluation of Analytical Methods including Detection and Quantification Capabilities”, which originally appeared in Pure and Applied Chemistry, 67 1699–1723 (1995) © 1995 IUPAC. Republication permission granted by IUPAC.1Analytica Chimica Acta, 1999
- Reduction of electronic noise in inductively coupled plasma atomic emission and fluorescence spectrometric measurementsAnalytical Chemistry, 1983
- Limits for qualitative detection and quantitative determination. Application to radiochemistryAnalytical Chemistry, 1968