Brandon D. Wilson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brandon D. Wilson has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hyongsok Tom Soh
Stanford University
10 shared publications Michael Eisenstein
Department of Electrical Engineering
6 shared publications- Ian Andrew Paul Thompson
Department of Electrical Engineering Stanford University Stanford CA 94305 USA
3 shared publications Amani A. Hariri
Department of Electrical Engineering, Stanford University, Stanford, CA, 94305, USA
1 shared publication- Amani A. Hariri
Stanford University
1 shared publication Benjamin C. Wollant
Department of Electrical Engineering, Stanford University, Stanford, USA
1 shared publication
Latest Publications
- Open Access
- 18 October 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (43) , 43785-43792
Multiplexed Assay for Small-Molecule Quantification via Photo-cross-linking of Structure Switching Aptamers
There is an unmet need for molecular detection assays that enable the multiplexed quantification of small-molecule analytes. We present xPlex, an assay that combines aptamer switches with ultraviolet-cross-linkable complementary strands to record target-binding events. When the aptamer's small-molecule target is present, the cross-linkable strand is displaced, enabling PCR amplification and detection of the relevant aptamer. In the absence of that target, the aptamer is readily cross-linked to the strand, preventing amplification from happening. The resulting aptamer-specific amplicons can be detected and quantified in a multiplexed fashion using high-throughput sequencing. We demonstrate quantitative performance for a pair of small-molecule analytes, dopamine and glucose, and show that this assay retains good specificity with mixtures of the two molecules at various concentrations. We further show that xPlex can effectively evaluate the specificity of cross-reactive aptamers to a range of different small-molecule analytes. We believe that the xPlex assay format could offer a useful strategy for achieving multiplexed analysis of small-molecule targets in a variety of scenarios.
- 18 October 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (43) , 43785-43792
Open AccessMultiplexed Assay for Small-Molecule Quantification via Photo-cross-linking of Structure Switching Aptamers
There is an unmet need for molecular detection assays that enable the multiplexed quantification of small-molecule analytes. We present xPlex, an assay that combines aptamer switches with ultraviolet-cross-linkable complementary strands to record target-binding events. When the aptamer's small-molecule target is present, the cross-linkable strand is displaced, enabling PCR amplification and detection of the relevant aptamer. In the absence of that target, the aptamer is readily cross-linked to the strand, preventing amplification from happening. The resulting aptamer-specific amplicons can be detected and quantified in a multiplexed fashion using high-throughput sequencing. We demonstrate quantitative performance for a pair of small-molecule analytes, dopamine and glucose, and show that this assay retains good specificity with mixtures of the two molecules at various concentrations. We further show that xPlex can effectively evaluate the specificity of cross-reactive aptamers to a range of different small-molecule analytes. We believe that the xPlex assay format could offer a useful strategy for achieving multiplexed analysis of small-molecule targets in a variety of scenarios.
- Open Access
- 13 July 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-10
Extending the dynamic range of biomarker quantification through molecular equalization
Precision medicine requires highly scalable methods of multiplexed biomarker quantification that can accurately describe patient physiology. Unfortunately, contemporary molecular detection methods are generally limited to a dynamic range of sensitivity spanning just 3–4 orders of magnitude, whereas the actual physiological dynamic range of the human plasma proteome spans more than 10 orders of magnitude. Current methods rely on sample splitting and differential dilution to compensate for this mismatch, but such measures greatly limit the reproducibility and scalability that can be achieved—in particular, the effects of non-linear dilution can greatly confound the analysis of multiplexed assays. We describe here a two-pronged strategy for equalizing the signal generated by each analyte in a multiplexed panel, thereby enabling simultaneous quantification of targets spanning a wide range of concentrations. We apply our ‘EVROS’ strategy to a proximity ligation assay and demonstrate simultaneous quantification of four analytes present at concentrations spanning from low femtomolar to mid-nanomolar levels. In this initial demonstration, we achieve a dynamic range spanning seven orders of magnitude in a single 5 µl sample of undiluted human serum, highlighting the opportunity to achieve sensitive, accurate detection of diverse analytes in a highly multiplexed fashion.
- 13 July 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-10
Open AccessExtending the dynamic range of biomarker quantification through molecular equalization
Precision medicine requires highly scalable methods of multiplexed biomarker quantification that can accurately describe patient physiology. Unfortunately, contemporary molecular detection methods are generally limited to a dynamic range of sensitivity spanning just 3–4 orders of magnitude, whereas the actual physiological dynamic range of the human plasma proteome spans more than 10 orders of magnitude. Current methods rely on sample splitting and differential dilution to compensate for this mismatch, but such measures greatly limit the reproducibility and scalability that can be achieved—in particular, the effects of non-linear dilution can greatly confound the analysis of multiplexed assays. We describe here a two-pronged strategy for equalizing the signal generated by each analyte in a multiplexed panel, thereby enabling simultaneous quantification of targets spanning a wide range of concentrations. We apply our ‘EVROS’ strategy to a proximity ligation assay and demonstrate simultaneous quantification of four analytes present at concentrations spanning from low femtomolar to mid-nanomolar levels. In this initial demonstration, we achieve a dynamic range spanning seven orders of magnitude in a single 5 µl sample of undiluted human serum, highlighting the opportunity to achieve sensitive, accurate detection of diverse analytes in a highly multiplexed fashion.
- Open Access
- 18 November 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-15
Pre-equilibrium biosensors as an approach towards rapid and continuous molecular measurements
Almost all biosensors that use ligand-receptor binding operate under equilibrium conditions. However, at low ligand concentrations, the equilibration with the receptor (e.g., antibodies and aptamers) becomes slow and thus equilibrium-based biosensors are inherently limited in making measurements that are both rapid and sensitive. In this work, we provide a theoretical foundation for a method through which biosensors can quantitatively measure ligand concentration before reaching equilibrium. Rather than only measuring receptor binding at a single time-point, the pre-equilibrium approach leverages the receptor’s kinetic response to instantaneously quantify the changing ligand concentration. Importantly, by analyzing the biosensor output in frequency domain, rather than in the time domain, we show the degree to which noise in the biosensor affects the accuracy of the pre-equilibrium approach. Through this analysis, we provide the conditions under which the signal-to-noise ratio of the biosensor can be maximized for a given target concentration range and rate of change. As a model, we apply our theoretical analysis to continuous insulin measurement and show that with a properly selected antibody, the pre-equilibrium approach could make the continuous tracking of physiological insulin fluctuations possible.
- 18 November 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-15
Open AccessPre-equilibrium biosensors as an approach towards rapid and continuous molecular measurements
Almost all biosensors that use ligand-receptor binding operate under equilibrium conditions. However, at low ligand concentrations, the equilibration with the receptor (e.g., antibodies and aptamers) becomes slow and thus equilibrium-based biosensors are inherently limited in making measurements that are both rapid and sensitive. In this work, we provide a theoretical foundation for a method through which biosensors can quantitatively measure ligand concentration before reaching equilibrium. Rather than only measuring receptor binding at a single time-point, the pre-equilibrium approach leverages the receptor’s kinetic response to instantaneously quantify the changing ligand concentration. Importantly, by analyzing the biosensor output in frequency domain, rather than in the time domain, we show the degree to which noise in the biosensor affects the accuracy of the pre-equilibrium approach. Through this analysis, we provide the conditions under which the signal-to-noise ratio of the biosensor can be maximized for a given target concentration range and rate of change. As a model, we apply our theoretical analysis to continuous insulin measurement and show that with a properly selected antibody, the pre-equilibrium approach could make the continuous tracking of physiological insulin fluctuations possible.
- 21 December 2021
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 6 (3) , 227-231
Comparing assays via the resolution of molecular concentration
- 21 December 2021
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 6 (3) , 227-231
Comparing assays via the resolution of molecular concentration
- Open Access
A Metric for Quantifying the Resolution of Molecular Assays
Many assay developers focus on limit of detection (LOD) as a primary performance metric, and LOD is indeed useful for assays designed to determine the presence or absence of an analyte. However, LOD is less useful for ‘continuous assays’ designed to discriminate between concentrations of an analyte— e . g ., glucose monitoring in diabetes, where clinical care is guided by particular concentration ranges and thresholds. In such scenarios, it would be valuable to quantify discriminatory resolution— i . e ., whether an assay can differentiate 1 pM from 10 pM— but no such standardized metric currently exists. Here, we propose a useful solution, termed ‘resolution of molecular concentration’ (RMC). RMC offers a simple means for characterizing quantitative resolution and quickly comparing the quantitative performance of assays. By raising awareness of the limitations of current metrics for evaluating assay performance, we hope to empower the molecular diagnostics community to evaluate their methods in a more application-appropriate manner.
Open AccessA Metric for Quantifying the Resolution of Molecular Assays
Many assay developers focus on limit of detection (LOD) as a primary performance metric, and LOD is indeed useful for assays designed to determine the presence or absence of an analyte. However, LOD is less useful for ‘continuous assays’ designed to discriminate between concentrations of an analyte— e . g ., glucose monitoring in diabetes, where clinical care is guided by particular concentration ranges and thresholds. In such scenarios, it would be valuable to quantify discriminatory resolution— i . e ., whether an assay can differentiate 1 pM from 10 pM— but no such standardized metric currently exists. Here, we propose a useful solution, termed ‘resolution of molecular concentration’ (RMC). RMC offers a simple means for characterizing quantitative resolution and quickly comparing the quantitative performance of assays. By raising awareness of the limitations of current metrics for evaluating assay performance, we hope to empower the molecular diagnostics community to evaluate their methods in a more application-appropriate manner.
- 10 May 2020
- Published by Elsevier in Trends in Biochemical Sciences
- Vol. 45 (8) , 639-649
Re-Evaluating the Conventional Wisdom about Binding Assays
- 10 May 2020
- Published by Elsevier in Trends in Biochemical Sciences
- Vol. 45 (8) , 639-649
Re-Evaluating the Conventional Wisdom about Binding Assays
- Open Access
Re-evaluating the conventional wisdom about binding assays
Analytical technologies based on binding assays have evolved substantially since their inception nearly 60 years ago, but our conceptual understanding of molecular recognition has not kept pace. Indeed, contemporary technologies such as single-molecule and digital measurements have challenged, or even rendered obsolete, core aspects of the conventional wisdom related to binding assay design. Here, we explore the fundamental principles underlying molecular recognition systems, which we consider in terms of signals generated through concentration-dependent shifts in equilibrium. We challenge certain orthodoxies related to binding-based detection assays, including the primary importance of a low K D and the extent to which this parameter constrains dynamic range and limit of detection. Lastly, we identify key principles for designing binding assays optimally suited for a given detection application.
Open AccessRe-evaluating the conventional wisdom about binding assays
Analytical technologies based on binding assays have evolved substantially since their inception nearly 60 years ago, but our conceptual understanding of molecular recognition has not kept pace. Indeed, contemporary technologies such as single-molecule and digital measurements have challenged, or even rendered obsolete, core aspects of the conventional wisdom related to binding assay design. Here, we explore the fundamental principles underlying molecular recognition systems, which we consider in terms of signals generated through concentration-dependent shifts in equilibrium. We challenge certain orthodoxies related to binding-based detection assays, including the primary importance of a low K D and the extent to which this parameter constrains dynamic range and limit of detection. Lastly, we identify key principles for designing binding assays optimally suited for a given detection application.
- Open Access
- 7 November 2019
- Published by Springer Nature in Nature Communications
- Vol. 10 (1) , 1-9
Independent control of the thermodynamic and kinetic properties of aptamer switches
Molecular switches that change their conformation upon target binding offer powerful capabilities for biotechnology and synthetic biology. Aptamers are useful as molecular switches because they offer excellent binding properties, undergo reversible folding, and can be engineered into many nanostructures. Unfortunately, the thermodynamic and kinetic properties of the aptamer switches developed to date are intrinsically coupled, such that high temporal resolution can only be achieved at the cost of lower sensitivity or high background. Here, we describe a design strategy that decouples and enables independent control over the thermodynamics and kinetics of aptamer switches. Starting from a single aptamer, we create an array of aptamer switches with effective dissociation constants ranging from 10 μM to 40 mM and binding kinetics ranging from 170 ms to 3 s. Our strategy is broadly applicable to other aptamers, enabling the development of switches suitable for a diverse range of biotechnology applications.
- 7 November 2019
- Published by Springer Nature in Nature Communications
- Vol. 10 (1) , 1-9
Open AccessIndependent control of the thermodynamic and kinetic properties of aptamer switches
Molecular switches that change their conformation upon target binding offer powerful capabilities for biotechnology and synthetic biology. Aptamers are useful as molecular switches because they offer excellent binding properties, undergo reversible folding, and can be engineered into many nanostructures. Unfortunately, the thermodynamic and kinetic properties of the aptamer switches developed to date are intrinsically coupled, such that high temporal resolution can only be achieved at the cost of lower sensitivity or high background. Here, we describe a design strategy that decouples and enables independent control over the thermodynamics and kinetics of aptamer switches. Starting from a single aptamer, we create an array of aptamer switches with effective dissociation constants ranging from 10 μM to 40 mM and binding kinetics ranging from 170 ms to 3 s. Our strategy is broadly applicable to other aptamers, enabling the development of switches suitable for a diverse range of biotechnology applications.
- Open Access
Independent Control of the Thermodynamic and Kinetic Properties of Aptamer Switches
Molecular switches that change their conformation upon target binding offer powerful capabilities for biotechnology and synthetic biology. In particular, aptamers have proven useful as molecular switches because they offer excellent binding properties, undergo reversible folding, and can be readily engineered into a wide range of nanostructures. Unfortunately, the thermodynamic and kinetic properties of the aptamer switches developed to date are intrinsically coupled, such that high temporal resolution ( i.e. , switching time) can only be achieved at the cost of lower sensitivity or high background. Here, we describe a general design strategy that decouples the thermodynamic and kinetic behavior of aptamer switches to achieve independent control of sensitivity and temporal resolution. We used this strategy to generate an array of aptamer switches with effective dissociation constants ( K D ) ranging from 10 μM to 40 mM and binding kinetics ranging from 170 ms to 3 s—all generated from the same parent ATP aptamer. Our strategy is broadly applicable to other aptamers, enabling the efficient development of switches with characteristics suitable for diverse range of biotechnology applications.
Open AccessIndependent Control of the Thermodynamic and Kinetic Properties of Aptamer Switches
Molecular switches that change their conformation upon target binding offer powerful capabilities for biotechnology and synthetic biology. In particular, aptamers have proven useful as molecular switches because they offer excellent binding properties, undergo reversible folding, and can be readily engineered into a wide range of nanostructures. Unfortunately, the thermodynamic and kinetic properties of the aptamer switches developed to date are intrinsically coupled, such that high temporal resolution ( i.e. , switching time) can only be achieved at the cost of lower sensitivity or high background. Here, we describe a general design strategy that decouples the thermodynamic and kinetic behavior of aptamer switches to achieve independent control of sensitivity and temporal resolution. We used this strategy to generate an array of aptamer switches with effective dissociation constants ( K D ) ranging from 10 μM to 40 mM and binding kinetics ranging from 170 ms to 3 s—all generated from the same parent ATP aptamer. Our strategy is broadly applicable to other aptamers, enabling the efficient development of switches with characteristics suitable for diverse range of biotechnology applications.
- Open Access
- 16 February 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
- p. 552224
High-Fidelity Nanopore Sequencing of Ultra-Short DNA Sequences
Nanopore sequencing offers a portable and affordable alternative to sequencing-by-synthesis methods but suffers from lower accuracy and cannot sequence ultra-short DNA. This puts applications such as molecular diagnostics based on the analysis of cell-free DNA or single-nucleotide variants (SNV) out of reach. To overcome these limitations, we report a nanopore-based sequencing strategy in which short target sequences are first circularized and then amplified via rolling-circle amplification to produce long stretches of concatemeric repeats. These can be sequenced on the Oxford Nanopore Technology’s (ONT) MinION platform, and the resulting repeat sequences aligned to produce a highly-accurate consensus that reduces the high error-rate present in the individual repeats. Using this approach, we demonstrate for the first time the ability to obtain unbiased and accurate nanopore data for target DNA sequences of < 100 bp. Critically, this approach is sensitive enough to achieve SNV discrimination in mixtures of sequences and even enables quantitative detection of specific variants present at ratios of < 10%. Our method is simple, cost-effective, and only requires well-established processes. It therefore expands the utility of nanopore sequencing for molecular diagnostics and other applications, especially in resource-limited settings.One Sentence Summary: We introduce a simple method of accurately sequencing ultra-short (<100bp) target DNA on a nanopore sequencing platform.
- 16 February 2019
- Published by Cold Spring Harbor Laboratory in bioRxiv
- p. 552224
Open AccessHigh-Fidelity Nanopore Sequencing of Ultra-Short DNA Sequences
Nanopore sequencing offers a portable and affordable alternative to sequencing-by-synthesis methods but suffers from lower accuracy and cannot sequence ultra-short DNA. This puts applications such as molecular diagnostics based on the analysis of cell-free DNA or single-nucleotide variants (SNV) out of reach. To overcome these limitations, we report a nanopore-based sequencing strategy in which short target sequences are first circularized and then amplified via rolling-circle amplification to produce long stretches of concatemeric repeats. These can be sequenced on the Oxford Nanopore Technology’s (ONT) MinION platform, and the resulting repeat sequences aligned to produce a highly-accurate consensus that reduces the high error-rate present in the individual repeats. Using this approach, we demonstrate for the first time the ability to obtain unbiased and accurate nanopore data for target DNA sequences of < 100 bp. Critically, this approach is sensitive enough to achieve SNV discrimination in mixtures of sequences and even enables quantitative detection of specific variants present at ratios of < 10%. Our method is simple, cost-effective, and only requires well-established processes. It therefore expands the utility of nanopore sequencing for molecular diagnostics and other applications, especially in resource-limited settings.One Sentence Summary: We introduce a simple method of accurately sequencing ultra-short (<100bp) target DNA on a nanopore sequencing platform.