Performance of NiTi endodontic instrument under different temperatures
- 22 August 2015
- journal article
- research article
- Published by Springer Nature in Odontology
- Vol. 104 (3) , 324-328
Abstract
The purpose of this study was to test nickel titanium (NiTi) instrument performance under different surrounding temperatures. Twenty-four superelastic NiTi instruments with a conical shape comprising a 0.30-mm-diameter tip and 0.06 taper were equally divided into 3 groups according to the temperature employed. Using a specially designed cyclic fatigue testing apparatus, each instrument was deflected to give a curvature 10 mm in radius and a 30° angle. This position was kept as the instrument was immersed in a continuous flow of water under a temperature of 10, 37, or 50 °C for 20 s to calculate the deflecting load (DL). In the same position, the instrument was then allowed to rotate at 300 rpm to fracture, and the working time was converted to the number of cycles to fracture (NCF). The statistical significance was set at p = 0.05. The mean DL (in N) and NCF (in cycles) of the groups at 10, 37, and 50 °C were 10.16 ± 1.36 and 135.50 ± 31.48, 13.50 ± 0.92 and 89.20 ± 16.44, and 14.70 ± 1.21 and 65.50 ± 15.90, respectively. The group at 10 °C had significantly the lowest DL that favorably resulted in the highest NCF. Within the limitations of this study, the surrounding temperature influences the cyclic fatigue resistance and DL of the superelastic NiTi instruments. Lower temperatures are found to favorably decrease the DL and extend the lifetime of the superelastic NiTi instrument. Further NiTi instrument failure studies should be performed under simulated body temperature.Keywords
This publication has 35 references indexed in Scilit:
- A metallurgical characterization of ten endodontic Ni‐Ti instruments: assessing the clinical relevance of shape memory and superelastic properties of Ni‐Ti endodontic instrumentsInternational Endodontic Journal, 2010
- A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary InstrumentsJournal of Endodontics, 2009
- Fatigue Resistance of Engine-driven Rotary Nickel-Titanium Instruments Produced by New Manufacturing MethodsJournal of Endodontics, 2008
- Vickers Hardness Investigation of Work-Hardening in Used NiTi Rotary InstrumentsJournal of Endodontics, 2006
- Defects in ProTaper S1 instruments after clinical use: fractographic examinationInternational Endodontic Journal, 2005
- Factors Influencing Defects of Rotary Nickel-Titanium Endodontic Instruments After Clinical UseJournal of Endodontics, 2004
- Cyclic fatigue of ProFile rotary instruments after prolonged clinical useInternational Endodontic Journal, 2001
- A comparison of stainless steel and nickel-titanium H-type instruments of identical design: Torsional and bending testsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2000
- Impact of Two Theoretical Cross-Sections on Torsional and Bending Stresses of Nickel-Titanium Root Canal Instrument ModelsJournal of Endodontics, 2000
- Cyclic fatigue testing of nickel-titanium endodontic instrumentsJournal of Endodontics, 1997