Multiscale modeling of skeletal muscle properties and experimental validations in isometric conditions
- 15 July 2011
- journal article
- research article
- Published by Springer Nature in Biological Cybernetics
- Vol. 105 (2) , 121-138
Abstract
In this article, we describe an approach to model the electromechanical behavior of the skeletal muscle based on the Huxley formulation. We propose a model that complies with a well established macroscopic behavior of striated muscles where force-length, force–velocity, and Mirsky–Parmley properties are taken into account. These properties are introduced at the microscopic scale and related to a tentative explanation of the phenomena. The method used integrates behavior ranging from the microscopic to the macroscopic scale, and allows the computation of the dynamics of the output force and stiffness controlled by EMG or stimulation parameters. The model can thus be used to simulate and carry out research to develop control strategies using electrical stimulation in the context of rehabilitation. Finally, through animal experiments, we estimated model parameters using a Sigma Point Kalman Filtering technique and dedicated experimental protocols in isometric conditions and demonstrated that the model can accurately simulate individual variations and thus take into account subject dependent behavior.Keywords
This publication has 38 references indexed in Scilit:
- Kinetics of neuromuscular changes during low‐frequency electrical stimulationMuscle & Nerve, 2009
- Mathematical model that predicts the force–intensity and force–frequency relationships after spinal cord injuriesMuscle & Nerve, 2007
- Modeling and estimation of the cardiac electromechanical activityComputers & Structures, 2006
- Original electronic design to perform epimysial and neural stimulation in paraplegiaJournal of Neural Engineering, 2006
- Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case reportIEEE Transactions on Rehabilitation Engineering, 1999
- Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegiaIEEE Transactions on Rehabilitation Engineering, 1997
- Lumbar Root Stimulation for Restoring Leg Function: Stimulator and Measurement of Muscle ActionsArtificial Organs, 1997
- Paraplegia: Prolonged Closed-Loop Standing with Implanted Nucleus FES-22 Stimulator and Andrews' Foot-Ankle OrthosisStereotactic and Functional Neurosurgery, 1997
- Determination of fatigue in the electrically stimulated quadriceps muscle and relative effect of ischaemiaJournal of Biomedical Engineering, 1993
- Optimum power output and structural design of sarcomeresJournal of Theoretical Biology, 1991