Abstract
Submodule (SM) fault is a common potential problem in the modular multilevel converter (MMC), which may lead to current distortion and even the collapse of the control system. This paper proposes a novel operation scheme for SM fault in medium voltage MMC applications. Firstly, when the fault number is low, the capacitor voltages increase to a lower value according to the operation status. Secondly, when the fault number is higher, the capacitor voltages increase to the rated value and the zero-sequence voltage (ZSV) is injected to maintain the normal operation of MMC. In addition, a virtual voltage idea is applied to simplify the modulation under SM faults, where the reconfigurations of carriers are not necessary. Compared with the conventional fault-tolerant method, the proposed method can enhance the ride-through capability of MMC and simplify the modulation process under SM faults. Simulation and experimental results verify the effectiveness of the proposed operation scheme under severe SM faults.
Funding Information
  • National Key Research and Development Program of China (2017YFB0903300)
  • Project of National Natural Science Foundation of China (51625702, 51807135)
  • Joint Fund Project of National Natural Science Foundation-State Grid Corporation (U1766210)

This publication has 28 references indexed in Scilit: