Symmetrical PolyMUMPs-Based Piezoresistive Microcantilever Sensors With On-Chip Temperature Compensation for Microfluidics Applications
Authors:
- Adisorn TuantranontATAdisorn Tuantranont
- Tanom LomasTLTanom Lomas
- Kata JaruwongrungseeKJKata Jaruwongrungsee
- Apichai JomphoakAJApichai Jomphoak
- Anurat WisitsoraatAWAnurat Wisitsoraat
- 23 May 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 8 (5) , 543-547
Abstract
Microelectromechanical systems (MEMS)-based cantilever beam sensors for microfluidics applications with on-chip temperature sensors for temperature drift compensation were developed. The stress induced on gold surface with polysilicon piezoresistive sensing is demonstrated. In principle, adsorption of biochemical species on a functionalized surface of the microfabricated cantilever will cause surface stress and, consequently, cantilever bending. The sensing mechanism relies on the piezoresistive properties of the doped polysilicon wire encapsulated in the beam. The beam is constructed through multiusers MEMS Process (PolyMUMPs) foundry with postprocessing silicon etching. Bending analysis is performed so that the beam tip deflection can be predicted. The piezoresistor designs on the beams were varied, within certain constraints, so that the sensitivity of the sensing technique could be measured by external read-out circuit. The mass detection of 0.0058-0.0110 g is measured by the beam resistor series as a balanced Wheatstone bridge configuration. The voltage output of the bridge is directly proportional to the amount of bending in the MEMS cantilever. The temperature dependency and sensor performance have been characterized in experiments. Compensation by resisters on the substrate significantly reduces the temperature dependence.Keywords
This publication has 9 references indexed in Scilit:
- Possibility of a femtogram mass biosensor using a self-sensing cantileverCurrent Applied Physics, 2006
- Optimised cantilever biosensor with piezoresistive read-outUltramicroscopy, 2003
- Nanosensors and biochips: frontiers in biomolecular diagnosticsSensors and Actuators B: Chemical, 2001
- Gold Nano-Structures for Transduction of Biomolecular Interactions into Micrometer Scale MovementsBiomedical Microdevices, 2001
- Atomic force microscopy probe with piezoresistive read-out and a highly symmetrical Wheatstone bridge arrangementSensors and Actuators A: Physical, 2000
- Environmental sensors based on micromachined cantilevers with integrated read-outUltramicroscopy, 2000
- Microcantilever-based biosensorsUltramicroscopy, 2000
- High-sensitivity piezoresistive cantilevers under 1000 Å thickApplied Physics Letters, 1999
- The tension of metallic films deposited by electrolysisProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1909