Tanom Lomas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tanom Lomas has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Adisorn Tuantranont
National Electronics and Computer Technology Center (NECTEC)
3 shared publications Anurat Wisitsoraat
Nanoelectronics and MEMS laboratory, National Electronics and Computer Technology Center (NECTEC), 112 Paholyothin Rd., Klong 1, Klong Luang, Pathumthani, Thailand
3 shared publicationsKata Jaruwongrungsee
Nanoelectronics and MEMS laboratory, National Electronics and Computer Technology Center (NECTEC), 112 Paholyothin Rd., Klong 1, Klong Luang, Pathumthani, Thailand
2 shared publications- Thitima Maturos
Nanoelectronics and MEMS laboratory, National Electronics and Computer Technology Center (NECTEC), 112 Paholyothin Rd., Klong 1, Klong Luang, Pathumthani, Thailand
2 shared publications Adisorn Tuantranont
Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Center, 112 Thailand Science Park, Pahol Yothin Rd., Klong Laung, Pathumthani 12120 Thailand. Tel: +662-564-6900, Fax: +662-564-6756
1 shared publication- Adisorn Tuantranont
Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Centre, Pathum Thani, 12120, Thailand
1 shared publication
Latest Publications
- 2 February 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (6) , 1059-1064
DNA hybridization enhancement using piezoelectric microagitation through a liquid coupling medium
In conventional DNA microarray hybridization, delivery of target cDNAs to surface-bounded probes depends solely on diffusion, which is notoriously slow, and thus typically requires 6–20 h to complete. In this study, piezoelectric microagitation through a liquid coupling medium is employed to enhance DNA hybridization efficiency and the results are compared with the standard static hybridization method. DNA hybridization was performed in a sealed aluminium chamber containing DNA microarray glass chip, coupling medium and piezoelectric transducers. 3 × SSC (Saline Sodium Citrate) was used as a coupling medium to prevent overheating of the piezoelectric transducers and to effectively transmit ultrasonic wave to the glass chip. Flow visualization using fluidic dye and velocimetry (PTV) technique was applied to observe fluid transport in the hybridization chamber. It was revealed that the dye solution was homogeneously distributed within 10 min under dynamic agitation while it took over 1 h to reach the same level of homogeneity in static condition. Plasmodium falciparumDNA microarrays and total RNA extracted from parasite cells were used as a model for DNA microarray experiments. It was found that the required hybridization time may be substantially reduced from 16 h to 4 h by the use of dynamic hybridization scheme. With the same hybridization time of 16 h, dynamic hybridization resulted in higher fluorescent signals of ∼33% and ∼24% compared to static hybridization in Cy3 and Cy5 channels, respectively. Additionally, good/effective spots, some of which were not formed by static method, were enhanced and distributed more uniformly over the microarray. Therefore, the developed dynamic hybridization with integrated piezoelectric microagitation platform is highly promising for DNA analysis in molecular biology and medical applications.
- 2 February 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (6) , 1059-1064
DNA hybridization enhancement using piezoelectric microagitation through a liquid coupling medium
In conventional DNA microarray hybridization, delivery of target cDNAs to surface-bounded probes depends solely on diffusion, which is notoriously slow, and thus typically requires 6–20 h to complete. In this study, piezoelectric microagitation through a liquid coupling medium is employed to enhance DNA hybridization efficiency and the results are compared with the standard static hybridization method. DNA hybridization was performed in a sealed aluminium chamber containing DNA microarray glass chip, coupling medium and piezoelectric transducers. 3 × SSC (Saline Sodium Citrate) was used as a coupling medium to prevent overheating of the piezoelectric transducers and to effectively transmit ultrasonic wave to the glass chip. Flow visualization using fluidic dye and velocimetry (PTV) technique was applied to observe fluid transport in the hybridization chamber. It was revealed that the dye solution was homogeneously distributed within 10 min under dynamic agitation while it took over 1 h to reach the same level of homogeneity in static condition. Plasmodium falciparumDNA microarrays and total RNA extracted from parasite cells were used as a model for DNA microarray experiments. It was found that the required hybridization time may be substantially reduced from 16 h to 4 h by the use of dynamic hybridization scheme. With the same hybridization time of 16 h, dynamic hybridization resulted in higher fluorescent signals of ∼33% and ∼24% compared to static hybridization in Cy3 and Cy5 channels, respectively. Additionally, good/effective spots, some of which were not formed by static method, were enhanced and distributed more uniformly over the microarray. Therefore, the developed dynamic hybridization with integrated piezoelectric microagitation platform is highly promising for DNA analysis in molecular biology and medical applications.
- Open Access
On-Chip Immunoassay for Determination of Urinary Albumin
An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993), with a detection limit of 0.81 mg L–1 (S/N = 3). The proposed system showed good precision, with relative standard deviations (RSDs) of 5.1%, when evaluated with 10 mg L–1 albumin (n = 10). Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r2 = 0.995; n = 15).
Open AccessOn-Chip Immunoassay for Determination of Urinary Albumin
An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993), with a detection limit of 0.81 mg L–1 (S/N = 3). The proposed system showed good precision, with relative standard deviations (RSDs) of 5.1%, when evaluated with 10 mg L–1 albumin (n = 10). Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r2 = 0.995; n = 15).
- 23 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 8 (5) , 543-547
Symmetrical PolyMUMPs-Based Piezoresistive Microcantilever Sensors With On-Chip Temperature Compensation for Microfluidics Applications
Microelectromechanical systems (MEMS)-based cantilever beam sensors for microfluidics applications with on-chip temperature sensors for temperature drift compensation were developed. The stress induced on gold surface with polysilicon piezoresistive sensing is demonstrated. In principle, adsorption of biochemical species on a functionalized surface of the microfabricated cantilever will cause surface stress and, consequently, cantilever bending. The sensing mechanism relies on the piezoresistive properties of the doped polysilicon wire encapsulated in the beam. The beam is constructed through multiusers MEMS Process (PolyMUMPs) foundry with postprocessing silicon etching. Bending analysis is performed so that the beam tip deflection can be predicted. The piezoresistor designs on the beams were varied, within certain constraints, so that the sensitivity of the sensing technique could be measured by external read-out circuit. The mass detection of 0.0058-0.0110 g is measured by the beam resistor series as a balanced Wheatstone bridge configuration. The voltage output of the bridge is directly proportional to the amount of bending in the MEMS cantilever. The temperature dependency and sensor performance have been characterized in experiments. Compensation by resisters on the substrate significantly reduces the temperature dependence.
- 23 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 8 (5) , 543-547
Symmetrical PolyMUMPs-Based Piezoresistive Microcantilever Sensors With On-Chip Temperature Compensation for Microfluidics Applications
Microelectromechanical systems (MEMS)-based cantilever beam sensors for microfluidics applications with on-chip temperature sensors for temperature drift compensation were developed. The stress induced on gold surface with polysilicon piezoresistive sensing is demonstrated. In principle, adsorption of biochemical species on a functionalized surface of the microfabricated cantilever will cause surface stress and, consequently, cantilever bending. The sensing mechanism relies on the piezoresistive properties of the doped polysilicon wire encapsulated in the beam. The beam is constructed through multiusers MEMS Process (PolyMUMPs) foundry with postprocessing silicon etching. Bending analysis is performed so that the beam tip deflection can be predicted. The piezoresistor designs on the beams were varied, within certain constraints, so that the sensitivity of the sensing technique could be measured by external read-out circuit. The mass detection of 0.0058-0.0110 g is measured by the beam resistor series as a balanced Wheatstone bridge configuration. The voltage output of the bridge is directly proportional to the amount of bending in the MEMS cantilever. The temperature dependency and sensor performance have been characterized in experiments. Compensation by resisters on the substrate significantly reduces the temperature dependence.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1313-1316
Polysilicon Piezoresistive Tactile Sensor Array Fabricated by PolyMUMPs Process
This paper discusses the design, fabrication and testing of a 5x5 micromachined tactile sensor array for the detection of an extremely small force (micrometer-Newton range). Central contacting pads that are trampoline-shape suspended structures and sensor beams are formed using an anisotropic etching of silicon substrate of a MUMPs process chip. A piezoresistive layer of polysilicon embedded in sensor beams is used to detect the displacement of the suspended contacting pad. Each square tactile has dimension of 200 mum x 200 mum with 250 mum center-to-center spacing. The entire sensor area is 1.25 mm x 1.25 mm. The device was characterized under various normal force loads using weight microneedles. The individual sensor element shows the linear response to normal force with good repeatability.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1313-1316
Polysilicon Piezoresistive Tactile Sensor Array Fabricated by PolyMUMPs Process
This paper discusses the design, fabrication and testing of a 5x5 micromachined tactile sensor array for the detection of an extremely small force (micrometer-Newton range). Central contacting pads that are trampoline-shape suspended structures and sensor beams are formed using an anisotropic etching of silicon substrate of a MUMPs process chip. A piezoresistive layer of polysilicon embedded in sensor beams is used to detect the displacement of the suspended contacting pad. Each square tactile has dimension of 200 mum x 200 mum with 250 mum center-to-center spacing. The entire sensor area is 1.25 mm x 1.25 mm. The device was characterized under various normal force loads using weight microneedles. The individual sensor element shows the linear response to normal force with good repeatability.
- 2 April 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5276, 221-230
MEMS micromirrors for optical switching in multichannel spectrophotometers
This paper reports for the first time that a novel MEMS-based micromirror switch has successfully demonstrated for optical switching in a multi-channel fiber optics spectrophotometer system. The conventional optomechanical fiber optic switches for multi-channel spectrophotometers available in market are bulky, slow, low numbers of channels and expensive. Our foundry MEMS-based micromirror switch designed for integrating with commercially available spectrophotometers offers more compact devices, increased number of probing channels, higher performance and cheaper. Our MEMS-based micromirror switch is a surface micromachined mirror fabricated through MUMPs foundry. The 280 μm x 280 μm gold coated mirror is suspended by the double-gimbal structure for X and Y axis scanning. Self-assembly by solders is used to elevate the torsion mirror 30 μm over the substrate to achieve large scan angle. The solder self-assembly approach dramatically reduces the time to assembly the switch. The scan mirror is electrostatically controlled by applying voltages. The individual probing signal from each probing head is guided by fibers with collimated lenses and incidents on the center of the mirror. The operating scan angle is in the range of 3.5 degrees with driving voltage of 0-100 V. The fastest switching time of 4 millisecond (1 ms rise time and 3 ms fall time) is measured corresponding to the maximum speed of the mirror of 0.25 kHz when the mirror is scanning at ± 1.5 degrees. The micromirror switch is packaged with a multi-mode fiber bundle using active alignment technique. A centered fiber is the output fiber that is connected to spectrophotometer. Maximum insertion loss of 5 dB has been obtained. The accuracy of measured spectral data is equivalent to the single channel spectrophotometer with a small degradation on probing signal due to fiber coupling.
- 2 April 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5276, 221-230
MEMS micromirrors for optical switching in multichannel spectrophotometers
This paper reports for the first time that a novel MEMS-based micromirror switch has successfully demonstrated for optical switching in a multi-channel fiber optics spectrophotometer system. The conventional optomechanical fiber optic switches for multi-channel spectrophotometers available in market are bulky, slow, low numbers of channels and expensive. Our foundry MEMS-based micromirror switch designed for integrating with commercially available spectrophotometers offers more compact devices, increased number of probing channels, higher performance and cheaper. Our MEMS-based micromirror switch is a surface micromachined mirror fabricated through MUMPs foundry. The 280 μm x 280 μm gold coated mirror is suspended by the double-gimbal structure for X and Y axis scanning. Self-assembly by solders is used to elevate the torsion mirror 30 μm over the substrate to achieve large scan angle. The solder self-assembly approach dramatically reduces the time to assembly the switch. The scan mirror is electrostatically controlled by applying voltages. The individual probing signal from each probing head is guided by fibers with collimated lenses and incidents on the center of the mirror. The operating scan angle is in the range of 3.5 degrees with driving voltage of 0-100 V. The fastest switching time of 4 millisecond (1 ms rise time and 3 ms fall time) is measured corresponding to the maximum speed of the mirror of 0.25 kHz when the mirror is scanning at ± 1.5 degrees. The micromirror switch is packaged with a multi-mode fiber bundle using active alignment technique. A centered fiber is the output fiber that is connected to spectrophotometer. Maximum insertion loss of 5 dB has been obtained. The accuracy of measured spectral data is equivalent to the single channel spectrophotometer with a small degradation on probing signal due to fiber coupling.