Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain
Authors:
- Timothy L. FoutzTFTimothy L. Foutz
- Kyle J. JohnsenKJKyle J. Johnsen
- Steven C. BudsbergSBSteven C. Budsberg
- 1 September 2014
- journal article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 75 (9) , 792-799
Abstract
Objective —To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. Sample —6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Procedures —Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Results —Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Conclusions and Clinical Relevance —Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by TKR.Keywords
This publication has 25 references indexed in Scilit:
- Canine Total Knee Replacement: Surgical Technique and One‐Year OutcomeVeterinary Surgery, 2009
- Effect of Tibial Plateau Leveling Osteotomy on Femorotibial Contact Mechanics and Stifle KinematicsVeterinary Surgery, 2008
- Prevalence of and risk factors for hip dysplasia and cranial cruciate ligament deficiency in dogsJournal of the American Veterinary Medical Association, 2008
- The Canine StifleClinical Techniques in Small Animal Practice, 2007
- INVITED REVIEW—Morphologic and Functional Features of the Canine Cruciate LigamentsVeterinary Surgery, 2006
- The Effect of Tibial Plateau Angle on Ground Reaction Forces 4–17 Months After Tibial Plateau Leveling Osteotomy in Labrador RetrieversVeterinary Surgery, 2006
- Estimate of the annual economic impact of treatment of cranial cruciate ligament injury in dogs in the United StatesJournal of the American Veterinary Medical Association, 2005
- Comparison of radiographic assessments of the tibial plateau slope in dogsAmerican Journal of Veterinary Research, 2003
- Effect of Tibial Plateau Leveling on Cranial and Caudal Tibial Thrusts in Canine Cranial Cruciate–Deficient Stifles: An In Vitro Experimental StudyVeterinary Surgery, 2001
- Mini Review of Canine Stifle Joint AnatomyAnatomia, Histologia, Embryologia, 2000