Timothy Lee Foutz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Timothy Lee Foutz has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
G. N. Rowland
§ Department of Avian Medicine, University of Georgia, Athens 30602
9 shared publicationsS. A. Thompson
4 shared publicationsA. K. Griffin
† Department of Biological and Agricultural Engineering
3 shared publicationsSteven C. Budsberg
3 shared publications- Alan R. Cross
Georgia Veterinary Specialists Atlanta GA
2 shared publications - AnnaMarie Conner
University of Georgia
2 shared publications
Latest Publications
- Open Access
- 1 January 2023
- Published by Virginia Tech Libraries in Journal of Technology Education
- Vol. 35 (1) , 7-31
Robotics and Coding: A Framework for Examining Cognitive Demand
Drawing on research in mathematics and science education that has supported student higher-level thinking in K-12 classrooms, we sought to classify the ways of thinking and reasoning supported by robotics coding tasks. As part of a larger project, we examined coding tasks implemented in elementary school classrooms and analyzed ways of thinking and reasoning about coding supported by these tasks. From this analysis, we developed a framework for analyzing the cognitive demand of coding tasks that can be used to support researchers, curriculum developers, and teachers in supporting students’ higher levels of thinking as they learn coding.
- 1 January 2023
- Published by Virginia Tech Libraries in Journal of Technology Education
- Vol. 35 (1) , 7-31
Open AccessRobotics and Coding: A Framework for Examining Cognitive Demand
Drawing on research in mathematics and science education that has supported student higher-level thinking in K-12 classrooms, we sought to classify the ways of thinking and reasoning supported by robotics coding tasks. As part of a larger project, we examined coding tasks implemented in elementary school classrooms and analyzed ways of thinking and reasoning about coding supported by these tasks. From this analysis, we developed a framework for analyzing the cognitive demand of coding tasks that can be used to support researchers, curriculum developers, and teachers in supporting students’ higher levels of thinking as they learn coding.
- 24 December 2020
- Published by Springer Nature
- p. 427-446
Argumentation in Primary Grades STEM Instruction: Examining Teachers’ Beliefs and Practices in the USA
- 24 December 2020
- Published by Springer Nature
- p. 427-446
Argumentation in Primary Grades STEM Instruction: Examining Teachers’ Beliefs and Practices in the USA
- 1 March 2020
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 81 (3) , 210-219
Impact of wearing a service vest on three-dimensional truncal motion in dogs
OBJECTIVE To develop a 3-D kinematic model to measure truncal motion in dogs and assess changes in truncal motion in dogs when wearing each of 2 service vests. ANIMALS 5 adult mixed-breed dogs. PRO...
- 1 March 2020
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 81 (3) , 210-219
Impact of wearing a service vest on three-dimensional truncal motion in dogs
OBJECTIVE To develop a 3-D kinematic model to measure truncal motion in dogs and assess changes in truncal motion in dogs when wearing each of 2 service vests. ANIMALS 5 adult mixed-breed dogs. PRO...
- 21 June 2018
- Published by Taylor & Francis in European Journal of Engineering Education
- Vol. 44 (3) , 312-329
Using argumentation as a learning strategy to improve student performance in engineering Statics
Research suggests that a significant reason that a large number of students earn low grades in the fundamental engineering science course Statics is that they may be entering the course with incorrect conceptual knowledge of mathematics and physics. The self-explanation learning approach called collective argumentation helps k-12 students to understand their misconceptions of mathematical principles that often appear abstract to them. This study investigated collective argumentation as an instructional approach that helps engineering students identify and correct their misconceptions of topics taught in Statics. Results suggest that argumentation improves student performance as measured by grades earned on semester exams. Survey and focus group results suggest that students did not understand the argumentation process. Therefore, the students did not like using it as a learning approach.
- 21 June 2018
- Published by Taylor & Francis in European Journal of Engineering Education
- Vol. 44 (3) , 312-329
Using argumentation as a learning strategy to improve student performance in engineering Statics
Research suggests that a significant reason that a large number of students earn low grades in the fundamental engineering science course Statics is that they may be entering the course with incorrect conceptual knowledge of mathematics and physics. The self-explanation learning approach called collective argumentation helps k-12 students to understand their misconceptions of mathematical principles that often appear abstract to them. This study investigated collective argumentation as an instructional approach that helps engineering students identify and correct their misconceptions of topics taught in Statics. Results suggest that argumentation improves student performance as measured by grades earned on semester exams. Survey and focus group results suggest that students did not understand the argumentation process. Therefore, the students did not like using it as a learning approach.
- 1 November 2016
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 29 (06) , 484-490
Evaluation of the relationship of tibiofemoral kinematics before and after total knee replacement in an in vitro model of cranial cruciate deficiency in the dog
Summary Objective: To investigate the relationship between tibiofemoral kinematics before and after total knee replacement (TKR) in vitro. Animals: Eight canine hemipelves. Methods: A modified Oxford Knee Rig was used to place cadaveric limbs through a range of passive motion allowing the kinematics of the stifle to be evaluated. Four measurements were performed: a control stage, followed by a cranial cruciate transection stage, then following TKR with the musculature intact stage, and finally TKR with removal of limb musculature stage. Joint angles and translations of the femur relative to the tibia, including flexion-extension versus adduction-abduction, flexion-extension versus internal-external rotation, as well as flexion-extension versus each translation (cranial-caudal and lateral-medial) were calculated. Results: Significant differences were identified in kinematic data from limbs following TKR implantation as compared to the unaltered stifle. The TKR resulted in significant decreases in external rotation of the stifle during flexion-extension compared to the limb prior to any intervention, as well as increasing the abduction. The TKR significantly increased the caudal translation of the femur relative to the tibia compared to the unaltered limb. When compared with the cranial cruciate ligament-transection stage, TKR significantly decreased the ratio of the external rotation to flexion. Discussion: All three test periods showed significant differences from the unaltered stifle. The TKR did not completely restore the normal kinematics of the stifle.
- 1 November 2016
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 29 (06) , 484-490
Evaluation of the relationship of tibiofemoral kinematics before and after total knee replacement in an in vitro model of cranial cruciate deficiency in the dog
Summary Objective: To investigate the relationship between tibiofemoral kinematics before and after total knee replacement (TKR) in vitro. Animals: Eight canine hemipelves. Methods: A modified Oxford Knee Rig was used to place cadaveric limbs through a range of passive motion allowing the kinematics of the stifle to be evaluated. Four measurements were performed: a control stage, followed by a cranial cruciate transection stage, then following TKR with the musculature intact stage, and finally TKR with removal of limb musculature stage. Joint angles and translations of the femur relative to the tibia, including flexion-extension versus adduction-abduction, flexion-extension versus internal-external rotation, as well as flexion-extension versus each translation (cranial-caudal and lateral-medial) were calculated. Results: Significant differences were identified in kinematic data from limbs following TKR implantation as compared to the unaltered stifle. The TKR resulted in significant decreases in external rotation of the stifle during flexion-extension compared to the limb prior to any intervention, as well as increasing the abduction. The TKR significantly increased the caudal translation of the femur relative to the tibia compared to the unaltered limb. When compared with the cranial cruciate ligament-transection stage, TKR significantly decreased the ratio of the external rotation to flexion. Discussion: All three test periods showed significant differences from the unaltered stifle. The TKR did not completely restore the normal kinematics of the stifle.
- 1 September 2014
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 75 (9) , 792-799
Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain
Objective —To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. Sample —6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Procedures —Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Results —Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Conclusions and Clinical Relevance —Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by TKR.
- 1 September 2014
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 75 (9) , 792-799
Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain
Objective —To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. Sample —6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Procedures —Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Results —Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Conclusions and Clinical Relevance —Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by TKR.
- 27 January 2014
- Published by Wiley in Veterinary Surgery
- Vol. 43 (6) , 741-749
Comparison of Tensile Strength and Early Healing of Acute Repeat Celiotomy Through a Ventral Median or a Right Ventral Paramedian Approach
To compare tensile strength, failure location, and histologic features after acute repeat celiotomy through a ventral median (RVM) or a right ventral paramedian (RVP) celiotomy in horses. Ex vivo experimental study. Adult horses (N = 18). Twelve adult horses had original ventral median (OVM) celiotomy. Repeat celiotomy was performed 72 hours postoperatively through the original ventral median (RVM, N = 6) or a RVP (N = 6) celiotomy. Celiotomies were scored daily for edema, drainage, and dehiscence. Fourteen days after repeat celiotomy, horses were euthanatized and abdominal wall containing celiotomy(ies) were collected for biomechanical and histological evaluation. The abdominal wall of control horses (N = 6; no celiotomy) was collected for biomechanical testing. Vital sign variables, incisional edema, and histologic scores were compared using a Wilcoxon signed-rank test. Incisional fibrotic depth and tensile strength per unit length (N/cm) was compared using repeated measures ANOVA. RVM and RVP horses had significantly less tensile strength compared to control horses, but no differences were observed between RVM and RVP horses. No differences in healing, inflammation, infection, or necrosis of repeat celiotomies was observed, but RVP horses accumulated more fibrin and hemorrhage within the incision. RVP horses had significantly greater incisional edema scores, but incisional drainage was more frequent in RVM horses. Acute repeat celiotomy through a RVM incision results in similar incisional healing and tensile strength compared with repeat celiotomy through a RVP incision.
- 27 January 2014
- Published by Wiley in Veterinary Surgery
- Vol. 43 (6) , 741-749
Comparison of Tensile Strength and Early Healing of Acute Repeat Celiotomy Through a Ventral Median or a Right Ventral Paramedian Approach
To compare tensile strength, failure location, and histologic features after acute repeat celiotomy through a ventral median (RVM) or a right ventral paramedian (RVP) celiotomy in horses. Ex vivo experimental study. Adult horses (N = 18). Twelve adult horses had original ventral median (OVM) celiotomy. Repeat celiotomy was performed 72 hours postoperatively through the original ventral median (RVM, N = 6) or a RVP (N = 6) celiotomy. Celiotomies were scored daily for edema, drainage, and dehiscence. Fourteen days after repeat celiotomy, horses were euthanatized and abdominal wall containing celiotomy(ies) were collected for biomechanical and histological evaluation. The abdominal wall of control horses (N = 6; no celiotomy) was collected for biomechanical testing. Vital sign variables, incisional edema, and histologic scores were compared using a Wilcoxon signed-rank test. Incisional fibrotic depth and tensile strength per unit length (N/cm) was compared using repeated measures ANOVA. RVM and RVP horses had significantly less tensile strength compared to control horses, but no differences were observed between RVM and RVP horses. No differences in healing, inflammation, infection, or necrosis of repeat celiotomies was observed, but RVP horses accumulated more fibrin and hemorrhage within the incision. RVP horses had significantly greater incisional edema scores, but incisional drainage was more frequent in RVM horses. Acute repeat celiotomy through a RVM incision results in similar incisional healing and tensile strength compared with repeat celiotomy through a RVP incision.
- 1 July 2012
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 73 (7) , 973-978
Diagnosis of lameness in dogs by use of artificial neural networks and ground reaction forces obtained during gait analysis
Objective —To evaluate the accuracy of artificial neural networks (ANNs) for use in predicting subjective diagnostic scores of lameness with variables determined from ground reaction force (GRF) data. Animals —21 adult mixed-breed dogs. Procedures —The left cranial cruciate ligament of each dog was transected to induce osteoarthritis of the stifle joint as part of another study. Lameness scores were assigned and GRF data were collected 2 times before and 5 times after ligament transection. Inputs and the output for each ANN were GRF variables and a lameness score, respectively. The ANNs were developed by use of data from 14 dogs and evaluated by use of data for the remaining 7 dogs (ie, dogs not used in model development). Results —ANN models developed with 2 preferred input variables had an overall accuracy ranging from 96% to 99% for 2 data configurations (data configuration 1 contained patterns or observations for 7 dogs, whereas data configuration 2 contained patterns or observations for 7 other dogs). When additional variables were added to the models, the highest overall accuracy ranged from 97% to 100%. Conclusions and Clinical Relevance —ANNs provided a method for processing GRF data of dogs to accurately predict subjective diagnostic scores of lameness. Processing of GRF data via ANNs could result in a more precise evaluation of surgical and pharmacological intervention by detecting subtle lameness that could have been missed by visual analysis of GRF curves.
- 1 July 2012
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 73 (7) , 973-978
Diagnosis of lameness in dogs by use of artificial neural networks and ground reaction forces obtained during gait analysis
Objective —To evaluate the accuracy of artificial neural networks (ANNs) for use in predicting subjective diagnostic scores of lameness with variables determined from ground reaction force (GRF) data. Animals —21 adult mixed-breed dogs. Procedures —The left cranial cruciate ligament of each dog was transected to induce osteoarthritis of the stifle joint as part of another study. Lameness scores were assigned and GRF data were collected 2 times before and 5 times after ligament transection. Inputs and the output for each ANN were GRF variables and a lameness score, respectively. The ANNs were developed by use of data from 14 dogs and evaluated by use of data for the remaining 7 dogs (ie, dogs not used in model development). Results —ANN models developed with 2 preferred input variables had an overall accuracy ranging from 96% to 99% for 2 data configurations (data configuration 1 contained patterns or observations for 7 dogs, whereas data configuration 2 contained patterns or observations for 7 other dogs). When additional variables were added to the models, the highest overall accuracy ranged from 97% to 100%. Conclusions and Clinical Relevance —ANNs provided a method for processing GRF data of dogs to accurately predict subjective diagnostic scores of lameness. Processing of GRF data via ANNs could result in a more precise evaluation of surgical and pharmacological intervention by detecting subtle lameness that could have been missed by visual analysis of GRF curves.
- 1 January 2012
- Published by American Society of Agricultural and Biological Engineers (ASABE) in Applied Engineering in Agriculture
- Vol. 28 (6) , 943-948
Kinematic Analysis of Broiler, Layer, and Turkey Stifles
- 1 January 2012
- Published by American Society of Agricultural and Biological Engineers (ASABE) in Applied Engineering in Agriculture
- Vol. 28 (6) , 943-948
Kinematic Analysis of Broiler, Layer, and Turkey Stifles
- 1 January 2009
- Published by American Society of Agricultural and Biological Engineers (ASABE) in Transactions of the ASABE
- Vol. 52 (1) , 235-238
A Simple System to Increase the Physical Activity of Broilers in Order to Reduce Body Fat
- 1 January 2009
- Published by American Society of Agricultural and Biological Engineers (ASABE) in Transactions of the ASABE
- Vol. 52 (1) , 235-238
A Simple System to Increase the Physical Activity of Broilers in Order to Reduce Body Fat