Abstract
The development of underground spaces is recognized as an effective solution to the resource shortages and traffic issues resulting from rapid urbanization. However, for underground spaces characterized by high population density, ensuring the safety of the indoor thermal environment has emerged as a critical factor to developing the resources of underground spaces. This paper examines the underground refuge chamber (URC) as a case study and investigates a safe and cost-effective combined temperature control scheme utilizing compressed air and phase change (CA-PC). Through experimental validation, the reliability of the numerical simulation model was confirmed, followed by an analysis of the impact of various factors—including the number of phase change plates (PCPs), per capita ventilation rate (PCVR), ventilation temperature (VT), per capita building area (PCBA), and latent heat (LH)—on the performance of temperature control via numerical simulation. The research findings indicate: (1) When employing mechanical ventilation for temperature regulation, the variation of indoor air temperature (IAT) over time follows an exponential function. (2) Only 10 PCPs with the LH of 250 kJ/kg are needed to ensure that the effective temperature control duration of the coupled temperature control scheme over 96 h, while fully utilizing the PCPs. (3) A functional relationship was established between IAT over time, relative dimensions of chamber, ventilation parameters, and the number of PCPs. These research outcomes hold significant implications for guiding the installation of combined temperature control systems utilizing CA-PC in various URCs.