Ruiyong Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruiyong Mao has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Zujing Zhang
College of Civil Engineering, Guizhou University, Guiyang, 550025, China
13 shared publicationsJiri Zhou
10 shared publications- Zujing Zhang
College of Civil Engineering, Guizhou Provincial Key Laboratory of Rock and Soil Mechanics and Engineering Safety, Guizhou University, Guiyang, China
9 shared publications Hongwei Wu
School of Physics, Engineering and Computer Science, University of Hertfordshire, Hatfield, AL10 9AB, UK
7 shared publications- Hongwei Wu
School of Physics, Engineering and Computer Science, University of Hertfordshire, Hatfield AL10 9AB, UK
7 shared publications Chao Li
4 shared publications
Latest Publications
- Open Access
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Investigation on thermal performance of a combined compressed air and phase change temperature control system in underground refuge chamber
The development of underground spaces is recognized as an effective solution to the resource shortages and traffic issues resulting from rapid urbanization. However, for underground spaces characterized by high population density, ensuring the safety of the indoor thermal environment has emerged as a critical factor to developing the resources of underground spaces. This paper examines the underground refuge chamber (URC) as a case study and investigates a safe and cost-effective combined temperature control scheme utilizing compressed air and phase change (CA-PC). Through experimental validation, the reliability of the numerical simulation model was confirmed, followed by an analysis of the impact of various factors—including the number of phase change plates (PCPs), per capita ventilation rate (PCVR), ventilation temperature (VT), per capita building area (PCBA), and latent heat (LH)—on the performance of temperature control via numerical simulation. The research findings indicate: (1) When employing mechanical ventilation for temperature regulation, the variation of indoor air temperature (IAT) over time follows an exponential function. (2) Only 10 PCPs with the LH of 250 kJ/kg are needed to ensure that the effective temperature control duration of the coupled temperature control scheme over 96 h, while fully utilizing the PCPs. (3) A functional relationship was established between IAT over time, relative dimensions of chamber, ventilation parameters, and the number of PCPs. These research outcomes hold significant implications for guiding the installation of combined temperature control systems utilizing CA-PC in various URCs.
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessInvestigation on thermal performance of a combined compressed air and phase change temperature control system in underground refuge chamber
The development of underground spaces is recognized as an effective solution to the resource shortages and traffic issues resulting from rapid urbanization. However, for underground spaces characterized by high population density, ensuring the safety of the indoor thermal environment has emerged as a critical factor to developing the resources of underground spaces. This paper examines the underground refuge chamber (URC) as a case study and investigates a safe and cost-effective combined temperature control scheme utilizing compressed air and phase change (CA-PC). Through experimental validation, the reliability of the numerical simulation model was confirmed, followed by an analysis of the impact of various factors—including the number of phase change plates (PCPs), per capita ventilation rate (PCVR), ventilation temperature (VT), per capita building area (PCBA), and latent heat (LH)—on the performance of temperature control via numerical simulation. The research findings indicate: (1) When employing mechanical ventilation for temperature regulation, the variation of indoor air temperature (IAT) over time follows an exponential function. (2) Only 10 PCPs with the LH of 250 kJ/kg are needed to ensure that the effective temperature control duration of the coupled temperature control scheme over 96 h, while fully utilizing the PCPs. (3) A functional relationship was established between IAT over time, relative dimensions of chamber, ventilation parameters, and the number of PCPs. These research outcomes hold significant implications for guiding the installation of combined temperature control systems utilizing CA-PC in various URCs.
- Open Access
- 7 July 2026
- Published by Elsevier in SSRN Electronic Journal
Prior-Guided Multi-Task Joint Forecasting and Storage Dispatch for Public Building Energy Systems with Photovoltaic Generation and Flexible Loads: A Case Study in Chengdu, China
With the rapid deployment of distributed photovoltaics (PV), building-side energy storage systems, and electric vehicle charging facilities, urban public buildings are gradually evolving into integrated energy nodes for coordinated source-load-storage operation. In this context, garage lighting load and charging pile load represent typical flexible building loads with different temporal patterns and behavior-driven characteristics. To address the limitations of existing studies in single-object forecasting, insufficient modeling of the coupling relationships among PV generation, flexible loads, and energy storage, and the lack of dispatch-level evaluation, this paper proposes a forecast-driven low-carbon energy management framework for public buildings and constructs a PG-WA-AE-TCN-GRU-MLKA multi-branch time-series forecasting model. The model constructs task-specific multi-scale input representations by combining wavelet decomposition (WA) and autoencoder latent features (AE), introduces a prior-guided soft gating mechanism to enhance key feature representation, and uses TCN-GRU-MLKA to extract local fluctuations, long-term dependencies, and multi-scale contextual information. Finally, the prediction results are input into a rule-based energy storage dispatch strategy, and the model performance is comprehensively evaluated from the aspects of prediction error, PV curtailment rate, and PV self-consumption rate. Experimental results show that the proposed model achieves an RMSE of 2.28 kWh, MAE of 0.95 kWh, WAPE of 30.17%, and R2 of 0.87 in joint forecasting. At the dispatch level, the PV curtailment amount and curtailment rate are 240.26 kWh and 4.93%, respectively, and the PV self-consumption rate reaches 95.07%. The results verify the effectiveness of the proposed method in improving multi-target forecasting accuracy, supporting energy storage dispatch, and promoting PV consumption.
- 7 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPrior-Guided Multi-Task Joint Forecasting and Storage Dispatch for Public Building Energy Systems with Photovoltaic Generation and Flexible Loads: A Case Study in Chengdu, China
With the rapid deployment of distributed photovoltaics (PV), building-side energy storage systems, and electric vehicle charging facilities, urban public buildings are gradually evolving into integrated energy nodes for coordinated source-load-storage operation. In this context, garage lighting load and charging pile load represent typical flexible building loads with different temporal patterns and behavior-driven characteristics. To address the limitations of existing studies in single-object forecasting, insufficient modeling of the coupling relationships among PV generation, flexible loads, and energy storage, and the lack of dispatch-level evaluation, this paper proposes a forecast-driven low-carbon energy management framework for public buildings and constructs a PG-WA-AE-TCN-GRU-MLKA multi-branch time-series forecasting model. The model constructs task-specific multi-scale input representations by combining wavelet decomposition (WA) and autoencoder latent features (AE), introduces a prior-guided soft gating mechanism to enhance key feature representation, and uses TCN-GRU-MLKA to extract local fluctuations, long-term dependencies, and multi-scale contextual information. Finally, the prediction results are input into a rule-based energy storage dispatch strategy, and the model performance is comprehensively evaluated from the aspects of prediction error, PV curtailment rate, and PV self-consumption rate. Experimental results show that the proposed model achieves an RMSE of 2.28 kWh, MAE of 0.95 kWh, WAPE of 30.17%, and R2 of 0.87 in joint forecasting. At the dispatch level, the PV curtailment amount and curtailment rate are 240.26 kWh and 4.93%, respectively, and the PV self-consumption rate reaches 95.07%. The results verify the effectiveness of the proposed method in improving multi-target forecasting accuracy, supporting energy storage dispatch, and promoting PV consumption.
- Open Access
- 6 July 2026
- Published by Elsevier in SSRN Electronic Journal
Multi-object power forecasting for grid-interactive building photovoltaic-storage-charging systems using a VMD-LSTM-CNN-KAN model: Evidence from a smart building
Accurate multi-object power forecasting is essential for the coordinated operation of grid-interactive photovoltaic-storage-charging systems in smart buildings. In building photovoltaic-storage-DC-direct flexibility (PSDC) systems, photovoltaic (PV) generation is highly intermittent and weather-dependent, while charging-pile loads are affected by stochastic user behavior and exhibit strong nonlinearity and temporal randomness. These uncertainties may weaken source-load matching and affect building’s energy management. To address this issue, this study proposes a hybrid forecasting model integrating variational mode decomposition (VMD), long short-term memory (LSTM), convolutional neural networks (CNN), and Kolmogorov–Arnold networks (KAN), abbreviated as VMD-LSTM-CNN-KAN (VLCK). The proposed model combines multi-scale decomposition, temporal dependency learning, local pattern extraction, and nonlinear feature mapping to improve forecasting accuracy. It is applied to a real building PSDC system for both source-side PV generation and load-side charging-pile demand forecasting. Results show that, for PV power forecasting, VLCK achieves an MSE of 0.0045, RMSE of 0.0671, MAE of 0.0447, and R2 of 0.9552, outperforming eight benchmark models. Under sunny, cloudy, and rainy conditions, its predicted curves show the closest agreement with actual PV output. During the transitional-season test, VLCK maintains the best comprehensive accuracy across three periods with different fluctuation characteristics. For charging-pile power forecasting, VLCK achieves an MSE of 0.0023, RMSE of 0.0480, MAE of 0.0289, and R2 of 0.9620. Ablation experiments further confirm the complementary contribution of VMD and KAN. These results indicate that VLCK can provide reliable source-load forecasting information for building-level PV-storage-charging coordination and grid-interactive energy management.
- 6 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMulti-object power forecasting for grid-interactive building photovoltaic-storage-charging systems using a VMD-LSTM-CNN-KAN model: Evidence from a smart building
Accurate multi-object power forecasting is essential for the coordinated operation of grid-interactive photovoltaic-storage-charging systems in smart buildings. In building photovoltaic-storage-DC-direct flexibility (PSDC) systems, photovoltaic (PV) generation is highly intermittent and weather-dependent, while charging-pile loads are affected by stochastic user behavior and exhibit strong nonlinearity and temporal randomness. These uncertainties may weaken source-load matching and affect building’s energy management. To address this issue, this study proposes a hybrid forecasting model integrating variational mode decomposition (VMD), long short-term memory (LSTM), convolutional neural networks (CNN), and Kolmogorov–Arnold networks (KAN), abbreviated as VMD-LSTM-CNN-KAN (VLCK). The proposed model combines multi-scale decomposition, temporal dependency learning, local pattern extraction, and nonlinear feature mapping to improve forecasting accuracy. It is applied to a real building PSDC system for both source-side PV generation and load-side charging-pile demand forecasting. Results show that, for PV power forecasting, VLCK achieves an MSE of 0.0045, RMSE of 0.0671, MAE of 0.0447, and R2 of 0.9552, outperforming eight benchmark models. Under sunny, cloudy, and rainy conditions, its predicted curves show the closest agreement with actual PV output. During the transitional-season test, VLCK maintains the best comprehensive accuracy across three periods with different fluctuation characteristics. For charging-pile power forecasting, VLCK achieves an MSE of 0.0023, RMSE of 0.0480, MAE of 0.0289, and R2 of 0.9620. Ablation experiments further confirm the complementary contribution of VMD and KAN. These results indicate that VLCK can provide reliable source-load forecasting information for building-level PV-storage-charging coordination and grid-interactive energy management.
- Open Access
- 25 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Optimising thermal performance in data centre server racks via a parametric layout configuration study
The rapid expansion of data centres has intensified the demand for low-threshold thermal optimisation strategies that avoid the high costs and operational disruptions associated with conventional infrastructure retrofits. This study focuses exclusively on in-rack server layout adjustments, specifically server power combination, arrangement methods, and air supply velocity. A dedicated experimental platform was constructed to represent a standard server rack environment, and physical single-factor and orthogonal experiments were conducted to evaluate cooling efficiency. Results indicate that: (1) Heat accumulates primarily at the rack top, producing pronounced temperature stratification. (2) The relative impact of the examined parameters on thermal performance ranks as follows: air supply velocity > power combination > arrangement method. (3) An optimal configuration—400 W × 10 servers positioned in the lower rack with an air supply velocity of 4 m/s—effectively alleviates heat imbalance and suppresses hot-spots. Compared with a non-optimised baseline, this configuration yielded measurable improvements in airflow utilisation and thermal uniformity. This work demonstrates that strategic in-rack layout adjustments alone can markedly enhance cooling performance without additional capital investment or infrastructure modifications, offering actionable guidance for data centre operators seeking practical, low-effort optimisation measures.
- 25 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessOptimising thermal performance in data centre server racks via a parametric layout configuration study
The rapid expansion of data centres has intensified the demand for low-threshold thermal optimisation strategies that avoid the high costs and operational disruptions associated with conventional infrastructure retrofits. This study focuses exclusively on in-rack server layout adjustments, specifically server power combination, arrangement methods, and air supply velocity. A dedicated experimental platform was constructed to represent a standard server rack environment, and physical single-factor and orthogonal experiments were conducted to evaluate cooling efficiency. Results indicate that: (1) Heat accumulates primarily at the rack top, producing pronounced temperature stratification. (2) The relative impact of the examined parameters on thermal performance ranks as follows: air supply velocity > power combination > arrangement method. (3) An optimal configuration—400 W × 10 servers positioned in the lower rack with an air supply velocity of 4 m/s—effectively alleviates heat imbalance and suppresses hot-spots. Compared with a non-optimised baseline, this configuration yielded measurable improvements in airflow utilisation and thermal uniformity. This work demonstrates that strategic in-rack layout adjustments alone can markedly enhance cooling performance without additional capital investment or infrastructure modifications, offering actionable guidance for data centre operators seeking practical, low-effort optimisation measures.
- Open Access
- 20 June 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 73
The thermal conductivity characteristics and prediction models of limestone sand-yellow soil mixtures
- 20 June 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 73
Open AccessThe thermal conductivity characteristics and prediction models of limestone sand-yellow soil mixtures
- 23 March 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 271
Study on performance and layout optimization of buried heat exchangers array in Karst landform
- 23 March 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 271
Study on performance and layout optimization of buried heat exchangers array in Karst landform
- 16 January 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 265
Study on multi-scale thermal management optimization for the configuration of a free cooling fan wall data center
- 16 January 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 265
Study on multi-scale thermal management optimization for the configuration of a free cooling fan wall data center
- 16 December 2024
- Published by Elsevier in Energy and Buildings
- Vol. 328
Experimental study on improving thermal management of fan-wall data center by setting baffles in cold aisle
- 16 December 2024
- Published by Elsevier in Energy and Buildings
- Vol. 328
Experimental study on improving thermal management of fan-wall data center by setting baffles in cold aisle
- 28 November 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 261
Numerical study of influence of karst fracture water on heat transfer performance of borehole heat exchanger
- 28 November 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 261
Numerical study of influence of karst fracture water on heat transfer performance of borehole heat exchanger