Abstract
This study presents a meta-analysis of sampling rates for per- and polyfluoroalkyl substances (PFAS) measured with microporous polyethylene tube (MPT) passive samplers, integrative tools used for monitoring pollutants in aquatic environments. Data from five independent field campaigns spanning groundwater, freshwater, and saltwater environments were compiled to recalculate sampling rates and evaluate the statistical influence of temperature, ambient PFAS concentrations, and deployment duration on MPT performance. A theoretical model describing PFAS transport through MPTs was refined and predicts sampling rates based solely on molecular weight, carbon number, and molar volume. The model incorporates radial diffusion in cylindrical coordinates and shows improved agreement with field observations. Average MPT sampling rates ranged from0.4−1.0mLday·cm in groundwater wells, consistent with the strong influence of the water boundary layer in low-flow regimes. Surface freshwater deployments exhibited higher sampling rates (2.7−7.2mLday·cm), whereas saltwater deployments showed reduced uptake (1.0−3.6mLday·cm), attributable to slowed diffusion in saline environments. Comparison of sampling rates derived from the compiled data, the theoretical model, and three additional reference studies yielded coefficients of variation of 29–74%.
Funding Information
  • National Institute of Environmental Health Sciences (P42ES027706)
  • Strategic Environmental Research and Development Program (ER20-1293)

This publication has 48 references indexed in Scilit: