Impact of extra-anatomical bypass on coarctation fluid dynamics using patient-specific lumped parameter and Lattice Boltzmann modeling
Open Access
- 11 June 2022
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-24
Abstract
Accurate hemodynamic analysis is not only crucial for successful diagnosis of coarctation of the aorta (COA), but intervention decisions also rely on the hemodynamics assessment in both pre and post intervention states to minimize patient risks. Despite ongoing advances in surgical techniques for COA treatments, the impacts of extra-anatomic bypass grafting, a surgical technique to treat COA, on the aorta are not always benign. Our objective was to investigate the impact of bypass grafting on aortic hemodynamics. We investigated the impact of bypass grafting on aortic hemodynamics using a patient-specific computational-mechanics framework in three patients with COA who underwent bypass grafting. Our results describe that bypass grafting improved some hemodynamic metrics while worsened the others: (1) Doppler pressure gradient improved (decreased) in all patients; (2) Bypass graft did not reduce the flow rate substantially through the COA; (3) Systemic arterial compliance increased in patients #1 and 3 and didn’t change (improve) in patient 3; (4) Hypertension got worse in all patients; (5) The flow velocity magnitude improved (reduced) in patient 2 and 3 but did not improve significantly in patient 1; (6) There were elevated velocity magnitude, persistence of vortical flow structure, elevated turbulence characteristics, and elevated wall shear stress at the bypass graft junctions in all patients. We concluded that bypass graft may lead to pseudoaneurysm formation and potential aortic rupture as well as intimal hyperplasia due to the persistent abnormal and irregular aortic hemodynamics in some patients. Moreover, post-intervention, exposures of endothelial cells to high shear stress may lead to arterial remodeling, aneurysm, and rupture.Keywords
Funding Information
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (Discovery Grant (RGPIN-2017-05349), Discovery Grant (RGPIN-2017-05349), Discovery Grant (RGPIN-2017-05349), Discovery Grant (RGPIN-2017-05349), Discovery Grant (RGPIN-2017-05349), Discovery Grant (RGPIN-2017-05349))
This publication has 113 references indexed in Scilit:
- Fluid Dynamics of Coarctation of the Aorta and Effect of Bicuspid Aortic ValvePLOS ONE, 2013
- Closed-loop real-time simulation model of hemodynamics and oxygen transport in the cardiovascular systemBioMedical Engineering OnLine, 2013
- Bicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending AortaCirculation: Cardiovascular Imaging, 2012
- Modeling the impact of concomitant aortic stenosis and coarctation of the aorta on left ventricular workloadJournal of Biomechanics, 2011
- Four-Dimensional Flow Magnetic Resonance Imaging With Wall Shear Stress Analysis Before and After Repair of Aortopulmonary FistulaCirculation: Cardiovascular Imaging, 2010
- ESC Guidelines for the management of grown-up congenital heart disease (new version 2010): The Task Force on the Management of Grown-up Congenital Heart Disease of the European Society of Cardiology (ESC)European Heart Journal, 2010
- Analysis of arterial intimal hyperplasia: review and hypothesisTheoretical Biology and Medical Modelling, 2007
- 3-D computational modeling of media flow through scaffolds in a perfusion bioreactorJournal of Biomechanics, 2005
- Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a reviewJournal of Artificial Organs, 2003
- Technique for extraanatomic bypass in complex aortic coarctationThe Annals of Thoracic Surgery, 1996