Abstract
In the classic energy sector, as well as in the manufacturing and process industries, Programmable Logic Controller (PLC) systems are used for electrical substation control. However, PLCs frequently do not support the communication protocols defined on the standard International Electrotechnical Commission (IEC) 61850. Therefore, this paper presents a vendor-independent method for the integration of Protection and Control (P&C) Intelligent Electronic Devices (IEDs), components of the substation bay level, in PLCs from the substation station level. The method can be used with legacy and modern controllers that offer an open communication interface, where the use of Transmission Control Protocol/Internet Protocol (TCP/IP) is supported. Since many legacy systems offer an open communication interface, this method makes it possible to reuse PLCs, bringing cost efficiency and ecological benefits. The method can be used in a single or redundant way since redundancy is always required in power distribution control. A prototype was developed for the integration over IEC 61850 Manufacturing Message Specification (MMS), and its functional validation is presented in this paper. This solution, besides reducing hardware and software acquisition costs, also contributes to a reduction in electronic waste (E-Waste) and the achievement of Sustainable Development Goals (SDGs).Keywords
This publication has 31 references indexed in Scilit:
- Exploring the Potential Application of IEC 61850 to Enable Energy Interconnectivity in Smart Grid SystemsIEEE Access, 2024
- Towards Automated Generation of Smart Grid Cyber Range for Cybersecurity Experiments and Training2023
- Link redundancy in the process bus according to IEC 61850 ED.2: experience with RSTP, PRP and HSR protocolsIET Conference Proceedings, 2022
- IEC 61850 Compatible OpenPLC for Cyber Attack Case Studies on Smart Substation SystemsIEEE Access, 2022
- OpenPLC61850: An IEC 61850 MMS compatible open source PLC for smart grid researchSoftwareX, 2022
- A Fixed-Latency Architecture to Secure GOOSE and Sampled Value Messages in Substation SystemsIEEE Access, 2021
- Intrusion Detection Against MMS-Based Measurement Attacks at Digital SubstationsIEEE Access, 2020
- IEC 61850 based substation automation system: A surveyInternational Journal of Electrical Power & Energy Systems, 2020
- Evaluation of Process Bus Data Latency with PRP/HSR Enabled Ethernet Switches2020
- OpenPLC: An IEC 61,131–3 compliant open source industrial controller for cyber security researchComputers & Security, 2018