Doppler and Volumetric Echocardiographic Methods for Cardiac Output Measurement in Standing Adult Horses
Authors:
- 1 March 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 27 (2) , 324-330
Abstract
Background: Cardiac output (CO) is not routinely measured in critically ill adult horses because of invasiveness of currently validated methods. Noninvasive CO monitoring would complement clinical assessment of hemodynamic status in adult horses. Hypothesis: Volumetric methods for measuring CO will have better agreement with lithium dilution than Doppler-based methods. Animals: Eight healthy adult horses. Methods: Prospective study. CO was manipulated with continuous rate infusions of dobutamine and romifidine to achieve high and low CO states, respectively. At each level, CO was measured by lithium dilution and various echocardiographic methods. Images stored as video loops were reviewed by an individual blinded to the lithium dilution results. Results: Lithium dilution determinations of CO ranged between 16.6 and 63.0 L/min. There was a significant effect of method of CO measurement (P < .001), but no significant effect of CO level (P = .089) or interaction between level and method (P = .607) on the absolute value of the bias. The absolute values of the bias of the right ventricular outflow tract (RVOT) Doppler, Simpson, 4-chamber area-length, and bullet methods [5.5, 6.1, 6.5, 8.8 L/min, respectively] were significantly lower than that of the left ventricular outflow tract (LVOT) Doppler or cubic methods [14.8, 24.3 L/min, respectively]. Conclusions and Clinical Importance: The 4-chamber area-length, Simpson, bullet, and RVOT Doppler provided better agreement with lithium dilution than the other methods evaluated. These methods warrant further investigation for use in critically ill adult horses.Keywords
Funding Information
- University of Georgia's Love
This publication has 42 references indexed in Scilit:
- Validation of Noninvasive Measurements of Cardiac Output in Mice Using EchocardiographyJournal of the American Society of Echocardiography, 2011
- Comparison between cardiovascular magnetic resonance and transthoracic doppler echocardiography for the estimation of effective orifice area in aortic stenosisJournal of Cardiovascular Magnetic Resonance, 2011
- Cardiac Output Monitoring: Is There a Gold Standard and How Do the Newer Technologies Compare?Seminars in Cardiothoracic and Vascular Anesthesia, 2010
- Determination of cardiac output in neonatal foals by ultrasound velocity dilution and its comparison to the lithium dilution methodJournal of Veterinary Emergency and Critical Care, 2009
- Comparison of Fick and thermodilution cardiac output determinations in standing horsesResearch in Veterinary Science, 2008
- Pulsed wave Doppler echocardiography in normal horsesEquine Veterinary Journal, 1995
- Determination of Cardiac Output by Echocardiography.Journal of Veterinary Medical Science, 1995
- Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques.Circulation, 1979
- Problems in echocardiographic volume determinations: Echocardiographic-angiographic correlations in the presence or absence of asynergyThe American Journal of Cardiology, 1976
- Left Ventricular Volumes and Ejection Fraction by EchocardiographyCirculation, 1971