Technical assessment of novel organic Rankine cycle driven cascade refrigeration system using environmental friendly refrigerants: 4E and optimization approaches
- 16 December 2022
- journal article
- research article
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (12) , 35096-35114
Abstract
Hydrocarbons are a promising working fluid for organic Rankine cycles and refrigeration systems that have gained increasing attention in recent decades as a replacement for the currently used higher global warming potential fluids. A novel standalone cascade refrigeration system (CRS) has been developed in this study for simultaneous ultra-low temperature cooling and heating production to medical applications most suitable for rural and power outages. Using the energy utilization factor (EUF) metrics, neopentane was chosen as the working fluid for the organic Rankine cycle (ORC) system among the selected hydrocarbon (HC) refrigerants. The standalone ORC-CRS system performance was investigated in terms of cooling and heating capacity, EUF, exergy, and environmental metrics by varying both ORC and CRS key temperature parameters. The exergy destruction of individual components was evaluated, and it was found that the ORC evaporator has the highest exergy destruction, followed by the expander. The highest EUF and exergy efficiency for a combined ORC-CRS system was about 0.64 and 38%. The maximum cooling and heating capacity of novel standalone CRS system was achieved by 70 kW and 225 kW respectively at a typical operating condition. At a higher ORC evaporation temperature, the exergy efficiency of the ORC-CRS system is decreased, leading to reduction in SI. The standalone ORC-CRS system at ORC evaporator temperature of 150 °C achieved the maximum CO2 emission tax savings of $ 6.4 × 107 over a 15-year lifetime period. The total annualized cost index of the combined cooling heating system is in the range between 35 and 60 $/h for the variable operating condition. Non-dominated sorting genetic algorithm II (NSGA-II) method was used to conduct the multi-objective optimization analysis, and the technique for order of preference by similarity to ideal solution (TOPSIS) method used to found the optimal point, which had the following values of TAC 42.22 $/h and exergy efficiency was around 46.10%.Keywords
Funding Information
- VIT University (VIT/HR/2021/7663)
This publication has 43 references indexed in Scilit:
- Energy and exergy assessments of modified Organic Rankine Cycles (ORCs)Energy Reports, 2015
- Effect and comparison of different working fluids on a two-stage organic rankine cycle (ORC) conceptApplied Thermal Engineering, 2014
- Systematic comparison of ORC configurations by means of comprehensive performance indexesApplied Thermal Engineering, 2013
- Hydrocarbon working fluids for a Rankine cycle powered vapor compression refrigeration system using low-grade thermal energyEnergy and Buildings, 2013
- Exergetic Evaluation of an Organic Rankine Cycle Using Medium-Grade Waste HeatEnergy Sources, Part A: Recovery, Utilization, and Environmental Effects, 2012
- Efficiency Improving Strategies of Low-temperature Heat Conversion Systems Using Organic Rankine Cycles: An OverviewEnergy Sources, Part A: Recovery, Utilization, and Environmental Effects, 2011
- Working fluids for high-temperature organic Rankine cyclesEnergy, 2011
- Theoretical analysis of a CO2–NH3 cascade refrigeration system for cooling applications at low temperaturesApplied Thermal Engineering, 2009
- Parametric optimization and comparative study of organic Rankine cycle (ORC) for low grade waste heat recoveryEnergy Conversion and Management, 2009
- Thermodynamic analysis of an R744–R717 cascade refrigeration systemInternational Journal of Refrigeration, 2008