Praveen Kumar Govindasamy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Praveen Kumar Govindasamy has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Coronas
Universitat Rovira i Virgili
3 shared publications Alberto Coronas
2 shared publicationsKarthikeyan Bhuvaneshwaran
CO2 Research and Green Technologies Centre, Vellore Institute of Technology, Vellore, India
2 shared publicationsR. Saravanan
2 shared publications- Rajagopal Saravanan
Anna University
2 shared publications A. Coronas
1 shared publication
Latest Publications
- 22 April 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (21) , 31632-31645
Driving an ecological transformation: unleashing multi-objective optimization for hydrogenated compressed natural gas in a decarbonization perspective
Integrating hydrogen with CNG is crucial for carbon neutrality and environmental goals, as it enhances flame temperature, reduces emissions, and combats global warming. This study employs the CHEMKIN tool to examine combustion characteristics, including adiabatic flame temperature, mole fraction, normalization, and production rate, in H2-CNG mixtures under various atmospheric and operating conditions. Blending 50% hydrogen with CNG results in significant changes, including a temperature increase from 2322 to 2344 K when the hydrogen content is at 50%. The introduction of hydrogen causes a notable 30–35% reduction in CH4 mole fraction and a simultaneous 26.6% increase in C-normalized CH4 production. Free radicals play a role in affecting CO2 production, with the normalization of CO species increasing from 0.068 to 0.087. Through NSGA-II multi-objective optimization methods, the study identifies a 50% H2-50% CNG blend as the optimal choice for thermal and environmental performance. The study explores the energy and environmental impacts of incorporating hydrogen into CNG-air combustion, with a specific focus on the effects of 50% H2 blending with CNG. Hydrogen blending benefits from elevated adiabatic flame temperature and increased free radical formation, ultimately leading to emission reduction. These findings firmly establish H2-CNG mixtures as promising environmentally friendly alternatives with superior combustion characteristics. Their potential paves the way for significant progress towards achieving carbon neutrality and combating climate change through cleaner, more efficient fuel options.
- 22 April 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (21) , 31632-31645
Driving an ecological transformation: unleashing multi-objective optimization for hydrogenated compressed natural gas in a decarbonization perspective
Integrating hydrogen with CNG is crucial for carbon neutrality and environmental goals, as it enhances flame temperature, reduces emissions, and combats global warming. This study employs the CHEMKIN tool to examine combustion characteristics, including adiabatic flame temperature, mole fraction, normalization, and production rate, in H2-CNG mixtures under various atmospheric and operating conditions. Blending 50% hydrogen with CNG results in significant changes, including a temperature increase from 2322 to 2344 K when the hydrogen content is at 50%. The introduction of hydrogen causes a notable 30–35% reduction in CH4 mole fraction and a simultaneous 26.6% increase in C-normalized CH4 production. Free radicals play a role in affecting CO2 production, with the normalization of CO species increasing from 0.068 to 0.087. Through NSGA-II multi-objective optimization methods, the study identifies a 50% H2-50% CNG blend as the optimal choice for thermal and environmental performance. The study explores the energy and environmental impacts of incorporating hydrogen into CNG-air combustion, with a specific focus on the effects of 50% H2 blending with CNG. Hydrogen blending benefits from elevated adiabatic flame temperature and increased free radical formation, ultimately leading to emission reduction. These findings firmly establish H2-CNG mixtures as promising environmentally friendly alternatives with superior combustion characteristics. Their potential paves the way for significant progress towards achieving carbon neutrality and combating climate change through cleaner, more efficient fuel options.
- Open Access
- 31 October 2023
- Published by Qeios Ltd
Review of: "Technical and Financial Viability of a 1 MW CSP Power Plant with Organic Rankine Module: Case Study for a Northeastern Brazilian City"
* The papers didn’t have any research inference , theres is no proper calculation for LCOE. * Provided reference papers for authors to rewrite the complete research paper: * Walraven, Daniël, Ben Laenen, and William D’haeseleer. "Minimizing the l...
- 31 October 2023
- Published by Qeios Ltd
Open AccessReview of: "Technical and Financial Viability of a 1 MW CSP Power Plant with Organic Rankine Module: Case Study for a Northeastern Brazilian City"
* The papers didn’t have any research inference , theres is no proper calculation for LCOE. * Provided reference papers for authors to rewrite the complete research paper: * Walraven, Daniël, Ben Laenen, and William D’haeseleer. "Minimizing the l...
- Top Cited Papers
- 6 October 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 188
Fuelling the future: A review of non-renewable hydrogen production and storage techniques
- 6 October 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 188
Top Cited PapersFuelling the future: A review of non-renewable hydrogen production and storage techniques
- Top Cited PapersOpen Access
- 22 September 2023
- Published by Elsevier in Results in Engineering
- Vol. 20
Hydrogen towards sustainable transition: A review of production, economic, environmental impact and scaling factors
- 22 September 2023
- Published by Elsevier in Results in Engineering
- Vol. 20
Top Cited PapersOpen AccessHydrogen towards sustainable transition: A review of production, economic, environmental impact and scaling factors
- 24 May 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series C
- Vol. 104 (4) , 845-851
Studies on Vapor Compression System Cascaded to the Ammonia Vapor Absorption System for Deep Freezing Application
- 24 May 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series C
- Vol. 104 (4) , 845-851
Studies on Vapor Compression System Cascaded to the Ammonia Vapor Absorption System for Deep Freezing Application
- 16 December 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (12) , 35096-35114
Technical assessment of novel organic Rankine cycle driven cascade refrigeration system using environmental friendly refrigerants: 4E and optimization approaches
Hydrocarbons are a promising working fluid for organic Rankine cycles and refrigeration systems that have gained increasing attention in recent decades as a replacement for the currently used higher global warming potential fluids. A novel standalone cascade refrigeration system (CRS) has been developed in this study for simultaneous ultra-low temperature cooling and heating production to medical applications most suitable for rural and power outages. Using the energy utilization factor (EUF) metrics, neopentane was chosen as the working fluid for the organic Rankine cycle (ORC) system among the selected hydrocarbon (HC) refrigerants. The standalone ORC-CRS system performance was investigated in terms of cooling and heating capacity, EUF, exergy, and environmental metrics by varying both ORC and CRS key temperature parameters. The exergy destruction of individual components was evaluated, and it was found that the ORC evaporator has the highest exergy destruction, followed by the expander. The highest EUF and exergy efficiency for a combined ORC-CRS system was about 0.64 and 38%. The maximum cooling and heating capacity of novel standalone CRS system was achieved by 70 kW and 225 kW respectively at a typical operating condition. At a higher ORC evaporation temperature, the exergy efficiency of the ORC-CRS system is decreased, leading to reduction in SI. The standalone ORC-CRS system at ORC evaporator temperature of 150 °C achieved the maximum CO2 emission tax savings of $ 6.4 × 107 over a 15-year lifetime period. The total annualized cost index of the combined cooling heating system is in the range between 35 and 60 $/h for the variable operating condition. Non-dominated sorting genetic algorithm II (NSGA-II) method was used to conduct the multi-objective optimization analysis, and the technique for order of preference by similarity to ideal solution (TOPSIS) method used to found the optimal point, which had the following values of TAC 42.22 $/h and exergy efficiency was around 46.10%.
- 16 December 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (12) , 35096-35114
Technical assessment of novel organic Rankine cycle driven cascade refrigeration system using environmental friendly refrigerants: 4E and optimization approaches
Hydrocarbons are a promising working fluid for organic Rankine cycles and refrigeration systems that have gained increasing attention in recent decades as a replacement for the currently used higher global warming potential fluids. A novel standalone cascade refrigeration system (CRS) has been developed in this study for simultaneous ultra-low temperature cooling and heating production to medical applications most suitable for rural and power outages. Using the energy utilization factor (EUF) metrics, neopentane was chosen as the working fluid for the organic Rankine cycle (ORC) system among the selected hydrocarbon (HC) refrigerants. The standalone ORC-CRS system performance was investigated in terms of cooling and heating capacity, EUF, exergy, and environmental metrics by varying both ORC and CRS key temperature parameters. The exergy destruction of individual components was evaluated, and it was found that the ORC evaporator has the highest exergy destruction, followed by the expander. The highest EUF and exergy efficiency for a combined ORC-CRS system was about 0.64 and 38%. The maximum cooling and heating capacity of novel standalone CRS system was achieved by 70 kW and 225 kW respectively at a typical operating condition. At a higher ORC evaporation temperature, the exergy efficiency of the ORC-CRS system is decreased, leading to reduction in SI. The standalone ORC-CRS system at ORC evaporator temperature of 150 °C achieved the maximum CO2 emission tax savings of $ 6.4 × 107 over a 15-year lifetime period. The total annualized cost index of the combined cooling heating system is in the range between 35 and 60 $/h for the variable operating condition. Non-dominated sorting genetic algorithm II (NSGA-II) method was used to conduct the multi-objective optimization analysis, and the technique for order of preference by similarity to ideal solution (TOPSIS) method used to found the optimal point, which had the following values of TAC 42.22 $/h and exergy efficiency was around 46.10%.