The Cover Depth Effect on Corrosion-Induced Deterioration of Reinforced Concrete Focusing on Water Penetration: Field Survey and Laboratory Study
Open Access
Abstract
Reinforced concrete bridges were visually surveyed in Japan, Thailand, and Vietnam to study the deterioration caused by internal steel corrosion under different climates, focusing on the concrete cover depth. Spalling or cracking arising from corrosion is likely where water is supplied. According to prior studies and our surveys, a concrete cover depth of more than 40 mm was found to prevent spalling, regardless of environmental conditions and structure age. Because water supply at steel is a key corrosion factor, it was hypothesised that under natural conditions, the water penetration in concrete would remain at a depth of approximately 40 mm. Our laboratory study examined water penetration under drying and wetting conditions. The results also suggested that under periodic rainfall conditions, the threshold of water penetration was not exceeded. The numerical study indicated maximum moisture evaporation to facilitate oxygen diffusion occurred at a depth of approximately 30–40 mm unless the concrete was exposed to continuous drying for more than one month. It was experimentally and numerically concluded that an adequate cover depth of greater than 40 mm could inhibit moisture and oxygen penetration at the steel, which supported the survey findings of cover depth effect on a high resistance to corrosion-induced deterioration despite an increase in service life.Keywords
Funding Information
- Japan Science and Technology Agency (Cross‐Ministerial Strategic Innovation Promotion Program (SIP))
- Japan Society for the Promotion of Science (Core-to-Core Program B. Asia-Africa Science Platforms)
- Japan Society of Civil Engineers (Research Promotion for International Deployment of Infrastructure Management Technology)
This publication has 20 references indexed in Scilit:
- Experimental investigations on the effect of concrete quality, exposure conditions and duration of initial moist curing on carbonation rate in concretes exposed to urban, inland environmentConstruction and Building Materials, 2020
- Durability Design Method Considering Reinforcement Corrosion due to Water PenetrationJournal of Advanced Concrete Technology, 2020
- STUDY ON THE EFFECT OF RAIN EXPOSURE ON CARBONATION-INDUCED SPALLING / FALLING OF THE COVER CONCRETEJournal of Japan Society of Civil Engineers, Ser. E2 (Materials and Concrete Structures), 2018
- Corrosion rate of carbon steel in carbonated concrete – A critical reviewCement and Concrete Research, 2018
- Corrosion assessment of reinforced concrete elements of Torre Velasca in MilanCase Studies in Construction Materials, 2016
- Carbonation of Concrete Containing Mineral AdmixturesJournal of Materials in Civil Engineering, 2003
- INVESTIGATION OF FALLING ON CONCRETE FRAGMENTS FROM RC STRUCTURESDoboku Gakkai Ronbunshu, 2002
- Carbonation of fly ash concreteMagazine of Concrete Research, 1992
- Factors affecting the corrosion rate of steel in carbonated mortarsCorrosion Science, 1991