RSRaktipong Sahamitmongkol

Raktipong Sahamitmongkol

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Raktipong Sahamitmongkol has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Superabsorbent Polymer Size on Strength and Shrinkage in Concrete Mixtures

    by Wissawin Arckarapunyathorn, Pochpagee Markpiban, Raktipong Sahamitmongkol

    This study investigates the influence of superabsorbent polymer (SAP) particle size on the mechanical and shrinkage behavior of concrete. Five concrete mixtures were prepared using SAPs with varying size ranges: 150–300 µm, 300–600 µm, 600–1800 µm, and a blended mix combining 300–600 µm and 600–1180 µm. The primary focus was on evaluating compressive strength, elastic modulus, autogenous shrinkage, drying shrinkage, and total shrinkage. The mechanical performance and dimensional stability were measured at different curing ages, and microstructural analysis was conducted using X-ray fluorescence (XRF) at 7 days to examine changes in chemical composition. Results showed that smaller SAP sizes contributed to more homogeneous internal curing, improved hydration, and higher matrix density. In contrast, larger SAP particles were more effective in reducing shrinkage but slightly compromised strength and stiffness. This study emphasizes the importance of selecting appropriate SAP particle sizes to balance mechanical integrity and shrinkage control, contributing to the development of high-performance concrete with reduced cracking potential.


  • Open Access

    Impact of Superabsorbent Polymer on Shrinkage and Compressive Strength of Mortar and Concrete

    by Wissawin Arckarapunyathorn, Pochpagee Markpiban, Raktipong Sahamitmongkol

    This article aims to study the effects of mixtures with superabsorbent polymers (SAPs) when using different mixing methods. The mixing methods used in this study are the dry mixing method and wet mixing method. Autogenous shrinkage, total shrinkage, drying shrinkage, compressive strength, and curing sensitivity index values are investigated. The results show that mixtures with SAPs have reduced autogenous shrinkage and total shrinkage. Shrinkage is more effectively reduced by the dry SAP mixing method than the wet SAP mixing method. The compressive strength derived by the dry SAP mixing method is higher than that derived by the wet SAP mixing method.


  • Open Access

    Workability, Mechanical Properties, and Microstructure Analysis of Bottom Ash Mortar Reinforced with Recycled Tire Steel Fiber

    by Pochpagee Markpiban, Raktipong Sahamitmongkol

    Recycled tire steel fiber (RTSF) is added to mortar with pre-wetted bottom ash (BA) to enhance the mechanical properties of the mortar, in addition to providing an internal curing effect. This work investigated the mechanical properties of BA mortar, such as the compressive strength, splitting tensile strength, and flexural strength, including the heat of reactions and the total shrinkage, considering different contents of BA (i.e., 10%, 20%, and 30% replacements by volume of fine aggregate) and recycled steel fiber (RSF, i.e., 0.5% and 1.0% by volume). The results showed that BA reduced all mechanical properties; however, it increased the degree of hydration by raising the heat peak of hydration in the first 7 days, increasing the amount of calcium hydroxide at 28 days, and significantly refining the pore structure during the curing period. Regarding the effects of RTSF, the bridging effect positively affected the compressive strength, splitting tensile strength, and flexural strength of the mortar with 30% BA when 1% RTSF was added, increasing them by 25%, 46%, and 40%, respectively. Moreover, adding 1% RTSF reduced the total porosity of the mortar with 30% BA from 17.2% to 14.8%.


  • Open Access

    Mortar with Internal Curing Bottom Ash for Sand Shortage and Proper Curing

    by Pochpagee Markpiban, Wittawat Krudam, Raktipong Sahamitmongkol

    Using industrial waste such as bottom ash (BA) is a potential alternative to using sand for tackling the current shortage of natural resources in the construction industry. This, along with the internal curing concept, enables proper curing inside and out, especially for low water-to-cement (w/c) ratio concrete, which has low permeability. The current work investigated the flow, compressive strength, heat flow, and microstructure characteristics (using an electron microprobe analysis, EPMA) to evaluate the use of internal curing BA as a sand-replacing material. Partial replacements of fine aggregate with BA were prepared in five different mortars (0, 20%, and 45%), with a fixed water-to-cement (w/c) ratio of 0.35. Consequently, the heat peak increased when using BA compared to the control mortar, indicating a higher hydration rate. The compressive strength of mortar with BA exceeded 50–60 MPa by 28 days. On the microstructural level, BA showed an increase in the volume fraction of small pores from 3 to 50 mm. Moreover, the content of Ca(OH)2 in the mortar with BA increased from 3 to 28 d by enhancing the hydration. This study shows the possibility of valorizing BA as a sand replacement in the internal curing of concrete with a low w/c ratio.


  • Open Access

    Remediation of Punching Shear Failure Using Glass Fiber Reinforced Polymer (GFRP) Rods

    by Ekkachai Yooprasertchai, Ratchanon Dithaem, Titi Arnamwong, Raktipong Sahamitmongkol, Jira Jadekittichoke, Panuwat Joyklad, Qudeer Hussain

    The results of an experimental program on shear-strengthening of flat slabs using Glass Fiber Reinforced Polymer (GFRP) rods are presented. A total of seven specimens were tested under an upward concentric monotonic loading until failure. One specimen served as a control and was tested without any modification. The remaining six specimens were strengthened with post-installed GFRP rods in single (SG), double (DB), and radial (RD) patterns within shear critical parameters around the centric column. The results of this experimental study suggest that GFRP rods are capable of enhancing both the peak load and deformation capacity. Furthermore, brittle failure associated with punching shear failure was successfully avoided by all strengthening patterns. Of all of the patterns, the RD pattern resulted in maximum peak load increase and corresponding deformation capacity while the lowest bound was created by the SG pattern. The results suggested that SG, DB and RD patterns enhanced ultimate loads up to 9.1, 11.3 and 15.7% while corresponding deflections increased up to 109, 136 and 154%. Strain measurement on flexural reinforcement suggested that all strengthened specimens were able to withstand higher longitudinal strains than yield. It was further shown that reducing the spacing between the GFRP rods efficiently enhanced peak loads, nevertheless, neither this change was proportional, nor did it result in an enhanced energy dissipation capacity. In the end, recommendations of American Concrete Institute (ACI) for the shear strength of two-way systems were modified to incorporate the contributions from GFRP rods. The results indicate that the proposed analytical approach provides an excellent match with the experimental results.


  • Open Access

    The Cover Depth Effect on Corrosion-Induced Deterioration of Reinforced Concrete Focusing on Water Penetration: Field Survey and Laboratory Study

    by Shingo Asamoto, Junya Sato, Shinichiro Okazaki, Pang-Jo Chun, Raktipong Sahamitmongkol, Giang Hoang Nguyen

    Reinforced concrete bridges were visually surveyed in Japan, Thailand, and Vietnam to study the deterioration caused by internal steel corrosion under different climates, focusing on the concrete cover depth. Spalling or cracking arising from corrosion is likely where water is supplied. According to prior studies and our surveys, a concrete cover depth of more than 40 mm was found to prevent spalling, regardless of environmental conditions and structure age. Because water supply at steel is a key corrosion factor, it was hypothesised that under natural conditions, the water penetration in concrete would remain at a depth of approximately 40 mm. Our laboratory study examined water penetration under drying and wetting conditions. The results also suggested that under periodic rainfall conditions, the threshold of water penetration was not exceeded. The numerical study indicated maximum moisture evaporation to facilitate oxygen diffusion occurred at a depth of approximately 30–40 mm unless the concrete was exposed to continuous drying for more than one month. It was experimentally and numerically concluded that an adequate cover depth of greater than 40 mm could inhibit moisture and oxygen penetration at the steel, which supported the survey findings of cover depth effect on a high resistance to corrosion-induced deterioration despite an increase in service life.