Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy
- 29 July 2010
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 37 (8) , 4445-4455
Abstract
Purpose: The purpose of this study is to verify the characteristics of the positron emitter nuclei generated at each treatment site by proton irradiation.Methods: Proton therapy using a beam on‐line PET system mounted on a rotating gantry port (BOLPs‐RGp), which the authors developed, is provided at the National Cancer Center Kashiwa, Japan. BOLPs‐RGp is a monitoring system that can confirm the activity distribution of the proton irradiated volume by detection of a pair of annihilation gamma rays coincidentally from positron emitter nuclei generated by the target nuclear fragment reactions between irradiated proton nuclei and nuclei in the human body. Activity is measured from a start of proton irradiation to a period of 200 s after the end of the irradiation. The characteristics of the positron emitter nuclei generated in a patient's body were verified by the measurement of the activity distribution at each treatment site using BOLPs‐RGp.Results: The decay curves for measured activity were able to be approximated using two or three half‐life values regardless of the treatment site. The activity of half‐life value of about 2 min was important for a confirmation of the proton irradiated volume.Conclusions: In each proton treatment site, verification of the characteristics of the generated positron emitter nuclei was performed by using BOLPs‐RGp. For the monitoring of the proton irradiated volume, the detection of generated in a human body was important.Keywords
Funding Information
- Health and Labor Science Research
This publication has 21 references indexed in Scilit:
- The Development and Clinical Use of a Beam ON-LINE PET System Mounted on a Rotating Gantry Port in Proton TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- In-beam PET measurements of biological half-lives of12C irradiation induced β+-activityActa Oncologica, 2008
- Experimental verification of proton beam monitoring in a human body by use of activity image of positron-emitting nuclei generated by nuclear fragmentation reactionRadiological Physics and Technology, 2007
- Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- PET/CT imaging for treatment verification after proton therapy: A study with plastic phantoms and metallic implantsMedical Physics, 2007
- In-beam PET measurements of β+radioactivity induced by proton beamsPhysics in Medicine & Biology, 2001
- In-beam PET imaging for the control of heavy-ion tumour therapyIEEE Transactions on Nuclear Science, 1997
- Proton dose monitoring with PET: quantitative studies in LucitePhysics in Medicine & Biology, 1996
- Photon activation—15O decay studies of tumor blood flowMedical Physics, 1981
- Tissue Perfusion Rate Determined from the Decay of Oxygen-15 Activity After Photon Activation in SituScience, 1979