Novel Cardiac Coordinate Modeling System for Three-Dimensional Quantification of Inflow Cannula Malposition of HeartMate II LVADs
- 1 March 2018
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 64 (2) , 154-158
Abstract
Optimal function of left ventricular assist devices (LVADs) depends on proper alignment of the inflow cannula (IC). Quantitative guidelines for IC angulation are lacking because of variation in cardiac geometry and difficulty in analyzing three-dimensional (3D) cannula orientation relative to the left ventricle (LV). Based on contrast-enhanced computed tomography images from five normal and five clinically malpositioned IC cases in patients with HeartMate II LVADs, we developed a method for 3D quantification of IC malpositioning. Using Mimics image software (Materialise, Leuven, Belgium), the native heart, major arteries, and LVAD were segmented to create patient-specific 3D models, allowing LV cavity volume and long-axis length to be measured directly. The deviation of the IC was quantified in a cylindrical coordinate system at the IC insertion point relative to the mitral valve and septum, and IC occlusion was assessed by the distance between cannula inlet and the proximal endocardium. Compared with normal cases, patients with malpositioned pumps had shorter LV length (p = 0.03) and reduced pump pocket depth (p = 0.009). Malpositioned pumps may experience greater obstruction by the nearby myocardium. This quantitative 3D modeling tool may help identify different modes of pump malalignment and migration and may facilitate preoperative planning and minimally invasive approaches via virtual LVAD implantation.Keywords
This publication has 9 references indexed in Scilit:
- Seventh INTERMACS annual report: 15,000 patients and countingThe Journal of Heart and Lung Transplantation, 2015
- Radiologic assessment of HeartMate II position: Minimal pump migration after long-term supportThe Journal of Heart and Lung Transplantation, 2015
- Principles of HeartMate II Implantation to Avoid Pump Malposition and MigrationJournal of Cardiac Surgery, 2014
- Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: A multifactorial phenomenonThe Journal of Heart and Lung Transplantation, 2014
- Postimplant Left Ventricular Assist Device Fit Analysis Using Three-Dimensional ReconstructionASAIO Journal, 2013
- Surgical Technique Influences HeartMate II Left Ventricular Assist Device ThrombosisThe Annals of Thoracic Surgery, 2013
- Algorithm for the diagnosis and management of suspected pump thrombusThe Journal of Heart and Lung Transplantation, 2013
- Left ventricular assist device malposition interrogated by 4-D cine computed tomographyJournal of Cardiovascular Computed Tomography, 2011
- Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical RobotSpine, 2010