Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study
Authors:
- 4 January 2021
- journal article
- research article
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 55 (4) , 953-960
Abstract
Aim The objective of the study is to compare the accuracy of implant positioning and limb alignment achieved in robotic-arm assisted total knee arthroplasty(RATKA) and manual total knee arthroplasty(MTKA) to their respective preoperative plan. Patients and methods This was a prospective observational study conducted in a tertiary care centre between August 2018 and January 2020. 143 consecutive RATKA(105 patients) and 151 consecutive MTKA(111 patients) performed by two experienced arthroplasty surgeons were included. Two independent observers evaluated the accuracy of implant positioning by measuring the radiological parameters according to the Knee-Society-Roentgenographic-Evaluation-System and limb alignment from postoperative weight-bearing scanogram. Outcomes were defined, based on the degree of deviation of measurements from the planned position and alignment, as excellent(0–1.99°), acceptable(2.00–2.99°) and outlier(≥ 3.00°). Results There were no systematic differences in the demographic and baseline characteristics between RATKA and MTKA. Statistically significant outcomes were observed favouring robotic group for postoperative mechanical axis (p < .001), coronal inclination of the femoral component (p < 0.001), coronal inclination of tibial component (p < 0.001), and sagittal inclination of tibial component (p < 0.001). There was no significant difference in the sagittal inclination of the femoral component (p = 0.566). The percentage of knees in the 'excellent' group were higher in RATKA compared to MTKA. There was absolutely no outlier in terms of limb alignment in the RATKA group versus 23.8% (p < 0.001) in the MTKA group. All the measurements showed high interobserver and intraobserver reliability. Conclusion Robotic-arm assisted TKA executed the preoperative plan more accurately with respect to limb alignment and implant positioning compared to manual TKA, even when the surgeons were more experienced in the latter. Graphic abstractKeywords
This publication has 42 references indexed in Scilit:
- The Influence of Preoperative Deformity on Valgus Correction Angle: An Analysis of 503 Total Knee ArthroplastiesThe Journal of Arthroplasty, 2013
- The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional VarusClinical Orthopaedics and Related Research, 2012
- Alignment in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Robot-assisted Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- Mechanical Axis Cannot be Restored in Total Knee Arthroplasty With a Fixed Valgus Resection AngleThe Journal of Arthroplasty, 2007
- Alignment and orientation of the components in total knee replacement with and without navigation supportThe Journal of Bone and Joint Surgery. British volume, 2007
- Alignment in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2004
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004
- Robotic total knee arthroplastyThe accuracy of CT-based component placementActa Orthopaedica, 2004
- Primary and Revision Total Hip Replacement Using the Robodoc?? SystemClinical Orthopaedics and Related Research, 1998