Balu C. Babu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Balu C. Babu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anubhav Sharma
Department of Mathematics, Indian Institute of Technology Madras , Chennai 600036, Tamil Nadu
1 shared publication Greeshma C. Ravindran
Department of Biostatistics, Amrita School of Medicine, Kochi, India
1 shared publicationJai Thilak
Department of Orthopaedics, Amrita Institute of Medical Sciences, Kochi, India
1 shared publication- Jai Thilak
Department of Orthopedics, Amrita Institute of Medical Sciences and Research Centre, Kochi, India
1 shared publication Mohan Thadi
Department of Orthopaedics, Amrita Institute of Medical Sciences, Kochi, India
1 shared publication- Mohan Thadi
Department of Orthopaedics, Amrita Institute of Medical Sciences and Research Centre, Amrita Vishwa Vidyapeetham, Kochi, India
1 shared publication
Latest Publications
- 4 January 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 55 (4) , 953-960
Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study
Aim The objective of the study is to compare the accuracy of implant positioning and limb alignment achieved in robotic-arm assisted total knee arthroplasty(RATKA) and manual total knee arthroplasty(MTKA) to their respective preoperative plan. Patients and methods This was a prospective observational study conducted in a tertiary care centre between August 2018 and January 2020. 143 consecutive RATKA(105 patients) and 151 consecutive MTKA(111 patients) performed by two experienced arthroplasty surgeons were included. Two independent observers evaluated the accuracy of implant positioning by measuring the radiological parameters according to the Knee-Society-Roentgenographic-Evaluation-System and limb alignment from postoperative weight-bearing scanogram. Outcomes were defined, based on the degree of deviation of measurements from the planned position and alignment, as excellent(0–1.99°), acceptable(2.00–2.99°) and outlier(≥ 3.00°). Results There were no systematic differences in the demographic and baseline characteristics between RATKA and MTKA. Statistically significant outcomes were observed favouring robotic group for postoperative mechanical axis (p < .001), coronal inclination of the femoral component (p < 0.001), coronal inclination of tibial component (p < 0.001), and sagittal inclination of tibial component (p < 0.001). There was no significant difference in the sagittal inclination of the femoral component (p = 0.566). The percentage of knees in the 'excellent' group were higher in RATKA compared to MTKA. There was absolutely no outlier in terms of limb alignment in the RATKA group versus 23.8% (p < 0.001) in the MTKA group. All the measurements showed high interobserver and intraobserver reliability. Conclusion Robotic-arm assisted TKA executed the preoperative plan more accurately with respect to limb alignment and implant positioning compared to manual TKA, even when the surgeons were more experienced in the latter. Graphic abstract
- 4 January 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 55 (4) , 953-960
Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study
Aim The objective of the study is to compare the accuracy of implant positioning and limb alignment achieved in robotic-arm assisted total knee arthroplasty(RATKA) and manual total knee arthroplasty(MTKA) to their respective preoperative plan. Patients and methods This was a prospective observational study conducted in a tertiary care centre between August 2018 and January 2020. 143 consecutive RATKA(105 patients) and 151 consecutive MTKA(111 patients) performed by two experienced arthroplasty surgeons were included. Two independent observers evaluated the accuracy of implant positioning by measuring the radiological parameters according to the Knee-Society-Roentgenographic-Evaluation-System and limb alignment from postoperative weight-bearing scanogram. Outcomes were defined, based on the degree of deviation of measurements from the planned position and alignment, as excellent(0–1.99°), acceptable(2.00–2.99°) and outlier(≥ 3.00°). Results There were no systematic differences in the demographic and baseline characteristics between RATKA and MTKA. Statistically significant outcomes were observed favouring robotic group for postoperative mechanical axis (p < .001), coronal inclination of the femoral component (p < 0.001), coronal inclination of tibial component (p < 0.001), and sagittal inclination of tibial component (p < 0.001). There was no significant difference in the sagittal inclination of the femoral component (p = 0.566). The percentage of knees in the 'excellent' group were higher in RATKA compared to MTKA. There was absolutely no outlier in terms of limb alignment in the RATKA group versus 23.8% (p < 0.001) in the MTKA group. All the measurements showed high interobserver and intraobserver reliability. Conclusion Robotic-arm assisted TKA executed the preoperative plan more accurately with respect to limb alignment and implant positioning compared to manual TKA, even when the surgeons were more experienced in the latter. Graphic abstract
- Open Access
- 1 November 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 22, 367-371
Accuracy of tibial component positioning in the robotic arm assisted versus conventional unicompartmental knee arthroplasty
- 1 November 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 22, 367-371
Open AccessAccuracy of tibial component positioning in the robotic arm assisted versus conventional unicompartmental knee arthroplasty