Reference intervals for hematologic and coagulation tests in adult alpacas (Vicugna pacos)
- 24 October 2011
- journal article
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 40 (4) , 504-512
Abstract
Background: Species‐specific reference intervals are needed for interpretation of laboratory tests. Reference interval studies of alpacas have been limited by low numbers and use of outdated methods.Objectives: The aims of this study were to establish reference intervals for hematologic and coagulation tests in alpacas using a laser‐based hematology analyzer and a mechanical clot detection coagulation analyzer, respectively; to compare results for automated and manual differentialWBCand platelet counts and fibrinogen concentrations; and to examine the effect of herd and sex on hematologic tests in a population of alpacas.Methods: Blood collected from clinically healthy female and male adult alpacas (Vicugna pacos) from 5 herds underwent fullCBCanalysis using anADVIA2120 (n = 65). Blood smears were examined for manual differentialWBCcounts, platelet estimates, and morphologic examination of blood cells.PCVand plasma protein and heat‐precipitable fibrinogen concentration measured by refractometry were also determined. Partial thromboplastin time, prothrombin time, and clottable fibrinogen concentration were measured using aSTA Compact analyzer (n = 13). Reference intervals were established using 2.5th and 97.5th percentiles for hematologic analytes and minimum and maximum values for coagulation tests. Automated and manual differentialWBCcounts, platelet counts, and fibrinogen concentrations were compared. Results were also evaluated for herd‐ and sex‐associated effects.Results: Hematologic reference intervals for alpacas were similar to those reported previously, except for lowerRBC‐related results, which showed a herd bias. Correlations between automated and manual neutrophil, lymphocyte, eosinophil, and platelet counts were moderate to good, with weak to poor correlations for monocyte and basophil counts and fibrinogen concentrations. Owing to the low number of samples analyzed, reference intervals for coagulation tests should be considered estimated intervals.Conclusions: Reference intervals will be useful guides for interpreting hematologic and coagulation results in alpacas, particularly when using the same instrumentation and reagents.Keywords
This publication has 28 references indexed in Scilit:
- What is your diagnosis? Discrepancy in platelet counts determined using a Sysmex XT-2000 iV hematology analyzerVeterinary Clinical Pathology, 2010
- Estimation of reference intervals from small samples: an example using canine plasma creatinineVeterinary Clinical Pathology, 2009
- Canine complete blood counts: a comparison of four in‐office instruments with the ADVIA 120 and manual differential countsVeterinary Clinical Pathology, 2009
- Evaluation of equine hemograms using the ADVIA 120 as compared with an impedance counter and manual differential countVeterinary Clinical Pathology, 2008
- Is the inherent imprecision of manual leukocyte differential counts acceptable for quantitative purposes?Veterinary Clinical Pathology, 2006
- Acquired cervical scoliosis attributed to Parelaphostrongylus tenuis infection in an alpacaJournal of the American Veterinary Medical Association, 2006
- The ADVIA 2120 Hematology System: Flow Cytometry-Based Analysis of Blood and Body Fluids in the Routine Hematology LaboratoryLaboratory Hematology, 2005
- Haematological reference values for alpacasAustralian Veterinary Journal, 1992
- Haematology of clinically normal and abnormal captive llamas and guanacoesVeterinary Record, 1988
- Mean Platelet Volume Artifacts: The Effect of Anticoagulants and Temperature on Canine PlateletsVeterinary Clinical Pathology, 1986