Dominic R. Dawson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dominic R. Dawson has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Richard J. DeFrancisco
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, USA
2 shared publicationsTracy Stokol
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, USA
2 shared publicationsAlexandra J. Burton
1 shared publicationJames C. A. Hart
Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
1 shared publicationSusan D. Mix
Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, USA
1 shared publicationSusan L. Fubini
1 shared publication
Latest Publications
- 15 May 2013
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 242 (10) , 1419-1424
Spiral colon impaction in juvenile alpacas: 12 cases (2006–2010)
Objective—To describe clinical signs and treatment outcomes for juvenile alpacas with spiral colon impaction (SCI). Design—Retrospective case series. Animals—12 juvenile (< 6 months old) camelids with SCI. Procedures—Crias with SCI were identified by searching the medical records database of the Cornell University Equine and Farm Animal Hospital. A keyword-based search method was used. Inclusion required confirmation of SCI on the basis of surgical or necropsy findings. History, signalment, examination findings, diagnostic test results, medical treatments, and surgical reports as well as short- and long-term outcomes were reviewed. Peritoneal fluid parameters were compared with those of age-matched comparison crias in which SCI was suspected but ruled out at necropsy or exploratory celiotomy. Results—12 crias with confirmed SCI were identified. Common clinical signs included lethargy and diarrhea. Abdominal distention was observed in 9 crias. In 3 crias, a mass in the region of the spiral colon was palpated. Seven crias underwent peritoneal fluid analysis; compared with age-matched comparison crias, SCI-affected crias had higher peritoneal fluid nucleated cell counts and nucleated cell count-to-total protein concentration ratios. A ventral midline celiotomy was performed in 9 crias; 7 underwent an enterotomy, and 2 underwent transmural infusion of saline (0.9% NaCl) solution with manual breakdown of ingesta; 3 of these crias survived for at least 6 months. Conclusions and Clinical Relevance—Crias with SCI that were not resolved by medical management had a poor prognosis. During celiotomy, transmural infusion of saline solution with manual breakdown of ingesta provided a less invasive alternative to enterotomy.
- 15 May 2013
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 242 (10) , 1419-1424
Spiral colon impaction in juvenile alpacas: 12 cases (2006–2010)
Objective—To describe clinical signs and treatment outcomes for juvenile alpacas with spiral colon impaction (SCI). Design—Retrospective case series. Animals—12 juvenile (< 6 months old) camelids with SCI. Procedures—Crias with SCI were identified by searching the medical records database of the Cornell University Equine and Farm Animal Hospital. A keyword-based search method was used. Inclusion required confirmation of SCI on the basis of surgical or necropsy findings. History, signalment, examination findings, diagnostic test results, medical treatments, and surgical reports as well as short- and long-term outcomes were reviewed. Peritoneal fluid parameters were compared with those of age-matched comparison crias in which SCI was suspected but ruled out at necropsy or exploratory celiotomy. Results—12 crias with confirmed SCI were identified. Common clinical signs included lethargy and diarrhea. Abdominal distention was observed in 9 crias. In 3 crias, a mass in the region of the spiral colon was palpated. Seven crias underwent peritoneal fluid analysis; compared with age-matched comparison crias, SCI-affected crias had higher peritoneal fluid nucleated cell counts and nucleated cell count-to-total protein concentration ratios. A ventral midline celiotomy was performed in 9 crias; 7 underwent an enterotomy, and 2 underwent transmural infusion of saline (0.9% NaCl) solution with manual breakdown of ingesta; 3 of these crias survived for at least 6 months. Conclusions and Clinical Relevance—Crias with SCI that were not resolved by medical management had a poor prognosis. During celiotomy, transmural infusion of saline solution with manual breakdown of ingesta provided a less invasive alternative to enterotomy.
- 1 December 2011
- Published by Elsevier in Veterinary Clinics of North America: Equine Practice
- Vol. 27 (3) , 507-526
Toxins and Adverse Drug Reactions Affecting the Equine Nervous System
- 1 December 2011
- Published by Elsevier in Veterinary Clinics of North America: Equine Practice
- Vol. 27 (3) , 507-526
Toxins and Adverse Drug Reactions Affecting the Equine Nervous System
- 24 October 2011
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 40 (4) , 538-548
Reference intervals for biochemical analytes in serum and heparinized plasma and serum protein fractions in adult alpacas (Vicugna pacos)
Background: Species‐specific reference intervals for laboratory tests are required for diagnosis and management of disease. Few reports of reference intervals for biochemical analytes and protein fractions are available for alpacas.Objectives: The aims of this study were to establish reference intervals for biochemical analytes measured in both serum and plasma and in serum protein fractions, and to determine the influence of herd and sex on test results in a population of alpacas.Methods: Blood was collected from 74 healthy male and female adult alpacas (Vicugnapacos) from 5 herds into tubes with no anticoagulant or with sodium heparin and analyzed within 4 hours. Biochemical analytes and ionized calcium were measured using aHitachiPmodular automated chemistry analyzer and anABL‐800Flex blood‐gas analyzer, respectively, and protein fractions were measured by agarose gel electrophoresis of serum. Nonparametric statistical methods were used to determine reference intervals, results obtained from serum and plasma were compared, and effects of herd and sex were examined.Results: Serum and plasma samples from 71 and 74 alpacas, respectively, were used to establish reference intervals for serum and plasma biochemical analytes. Intervals were similar, although clinically relevant differences between creatine kinase activity and phosphate concentration were found in individual animals. Serum proteins from 60 alpacas were analyzed by electrophoresis. There were significant herd‐ and sex‐associated differences in some biochemical analytes and protein fractions; however, most had minimal impact on reference interval determination, with the exception of herd‐associated effects on concentrations of urea nitrogen, ionized calcium, and bile acids and transferrin saturation.Conclusions: Serum and plasma reference intervals are interchangeable; however, consistency of sample type is imperative when performing serial testing. Use of laboratory‐ and instrument‐specific reference intervals is optimal; however, intervals reported here may be used as a guide for interpreting laboratory results from alpacas, especially when test methods are the same.
- 24 October 2011
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 40 (4) , 538-548
Reference intervals for biochemical analytes in serum and heparinized plasma and serum protein fractions in adult alpacas (Vicugna pacos)
Background: Species‐specific reference intervals for laboratory tests are required for diagnosis and management of disease. Few reports of reference intervals for biochemical analytes and protein fractions are available for alpacas.Objectives: The aims of this study were to establish reference intervals for biochemical analytes measured in both serum and plasma and in serum protein fractions, and to determine the influence of herd and sex on test results in a population of alpacas.Methods: Blood was collected from 74 healthy male and female adult alpacas (Vicugnapacos) from 5 herds into tubes with no anticoagulant or with sodium heparin and analyzed within 4 hours. Biochemical analytes and ionized calcium were measured using aHitachiPmodular automated chemistry analyzer and anABL‐800Flex blood‐gas analyzer, respectively, and protein fractions were measured by agarose gel electrophoresis of serum. Nonparametric statistical methods were used to determine reference intervals, results obtained from serum and plasma were compared, and effects of herd and sex were examined.Results: Serum and plasma samples from 71 and 74 alpacas, respectively, were used to establish reference intervals for serum and plasma biochemical analytes. Intervals were similar, although clinically relevant differences between creatine kinase activity and phosphate concentration were found in individual animals. Serum proteins from 60 alpacas were analyzed by electrophoresis. There were significant herd‐ and sex‐associated differences in some biochemical analytes and protein fractions; however, most had minimal impact on reference interval determination, with the exception of herd‐associated effects on concentrations of urea nitrogen, ionized calcium, and bile acids and transferrin saturation.Conclusions: Serum and plasma reference intervals are interchangeable; however, consistency of sample type is imperative when performing serial testing. Use of laboratory‐ and instrument‐specific reference intervals is optimal; however, intervals reported here may be used as a guide for interpreting laboratory results from alpacas, especially when test methods are the same.
- 24 October 2011
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 40 (4) , 504-512
Reference intervals for hematologic and coagulation tests in adult alpacas (Vicugna pacos)
Background: Species‐specific reference intervals are needed for interpretation of laboratory tests. Reference interval studies of alpacas have been limited by low numbers and use of outdated methods.Objectives: The aims of this study were to establish reference intervals for hematologic and coagulation tests in alpacas using a laser‐based hematology analyzer and a mechanical clot detection coagulation analyzer, respectively; to compare results for automated and manual differentialWBCand platelet counts and fibrinogen concentrations; and to examine the effect of herd and sex on hematologic tests in a population of alpacas.Methods: Blood collected from clinically healthy female and male adult alpacas (Vicugna pacos) from 5 herds underwent fullCBCanalysis using anADVIA2120 (n = 65). Blood smears were examined for manual differentialWBCcounts, platelet estimates, and morphologic examination of blood cells.PCVand plasma protein and heat‐precipitable fibrinogen concentration measured by refractometry were also determined. Partial thromboplastin time, prothrombin time, and clottable fibrinogen concentration were measured using aSTA Compact analyzer (n = 13). Reference intervals were established using 2.5th and 97.5th percentiles for hematologic analytes and minimum and maximum values for coagulation tests. Automated and manual differentialWBCcounts, platelet counts, and fibrinogen concentrations were compared. Results were also evaluated for herd‐ and sex‐associated effects.Results: Hematologic reference intervals for alpacas were similar to those reported previously, except for lowerRBC‐related results, which showed a herd bias. Correlations between automated and manual neutrophil, lymphocyte, eosinophil, and platelet counts were moderate to good, with weak to poor correlations for monocyte and basophil counts and fibrinogen concentrations. Owing to the low number of samples analyzed, reference intervals for coagulation tests should be considered estimated intervals.Conclusions: Reference intervals will be useful guides for interpreting hematologic and coagulation results in alpacas, particularly when using the same instrumentation and reagents.
- 24 October 2011
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 40 (4) , 504-512
Reference intervals for hematologic and coagulation tests in adult alpacas (Vicugna pacos)
Background: Species‐specific reference intervals are needed for interpretation of laboratory tests. Reference interval studies of alpacas have been limited by low numbers and use of outdated methods.Objectives: The aims of this study were to establish reference intervals for hematologic and coagulation tests in alpacas using a laser‐based hematology analyzer and a mechanical clot detection coagulation analyzer, respectively; to compare results for automated and manual differentialWBCand platelet counts and fibrinogen concentrations; and to examine the effect of herd and sex on hematologic tests in a population of alpacas.Methods: Blood collected from clinically healthy female and male adult alpacas (Vicugna pacos) from 5 herds underwent fullCBCanalysis using anADVIA2120 (n = 65). Blood smears were examined for manual differentialWBCcounts, platelet estimates, and morphologic examination of blood cells.PCVand plasma protein and heat‐precipitable fibrinogen concentration measured by refractometry were also determined. Partial thromboplastin time, prothrombin time, and clottable fibrinogen concentration were measured using aSTA Compact analyzer (n = 13). Reference intervals were established using 2.5th and 97.5th percentiles for hematologic analytes and minimum and maximum values for coagulation tests. Automated and manual differentialWBCcounts, platelet counts, and fibrinogen concentrations were compared. Results were also evaluated for herd‐ and sex‐associated effects.Results: Hematologic reference intervals for alpacas were similar to those reported previously, except for lowerRBC‐related results, which showed a herd bias. Correlations between automated and manual neutrophil, lymphocyte, eosinophil, and platelet counts were moderate to good, with weak to poor correlations for monocyte and basophil counts and fibrinogen concentrations. Owing to the low number of samples analyzed, reference intervals for coagulation tests should be considered estimated intervals.Conclusions: Reference intervals will be useful guides for interpreting hematologic and coagulation results in alpacas, particularly when using the same instrumentation and reagents.