Case of difficult tracheostomy tube insertion: A novel yet simple solution to the dilemma
Authors:
Open Access
- 1 January 2013
- journal article
- case report
- Published by Medknow in Anesthesia: Essays and Researches
- Vol. 7 (3) , 402-4
Abstract
Difficulties arising during tracheostomy tube insertion can be rapidly fatal if the airway is not adequately controlled. We report a case of difficult tracheostomy in a gentleman with severe subcutaneous emphysema following a previously failed tracheostomy attempt. Tracheostomy tube insertion through the pre-existing stoma failed repeatedly due to rapidly increasing distance of trachea from the skin and unexpected false passages; however, the trachea was eventually cannulated using a regular endotracheal tube.Keywords
This publication has 9 references indexed in Scilit:
- Novel technique in difficult percutaneous tracheostomySaudi Journal of Anaesthesia, 2011
- Difficult tracheostomy tube placement in an obese patient with a short neck -A case report-Korean Journal of Anesthesiology, 2011
- Percutaneous tracheostomy: a 6 yr prospective evaluation of the single tapered dilator techniqueBritish Journal of Anaesthesia, 2010
- A comparative study of the complications of surgical tracheostomy in morbidly obese critically ill patientsCritical Care, 2007
- Percutaneous dilatational tracheostomy versus surgical tracheostomy in critically ill patients: a systematic review and meta-analysisCritical Care, 2006
- Tracheostomy Tubes and Related AppliancesRespiratory Care, 2005
- Comparison of two percutaneous tracheostomy techniques, guide wire dilating forceps and Ciaglia Blue Rhino: a sequential cohort studyCritical Care, 2004
- Percutaneous tracheostomy with the Blue Rhino™ technique: presentation of 100 consecutive patientsAnaesthesia, 2002
- Permanent tracheostomy with cervical lipectomyThe Laryngoscope, 1990