Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards
- 27 August 2011
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 401 (8) , 2639-2649
Abstract
A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of 81Br-labelled PBDEs for isotope dilution analysis and the measurement of 79Br/81Br isotope ratios in gas chromatography peaks with the electron capture negative ionization technique. The suitability of this ion source for the precise and accurate measurement of bromine isotope ratios has been demonstrated. The general ECNI-IDMS procedure was evaluated by the analysis of NIST SRM 1947 (Lake Michigan fish tissue) with satisfactory results. For the analysis of water samples, 500 mL of the samples were spiked with the labelled PBDEs and extracted with 10 mL isooctane for 30 min. The extract was evaporated down to ca. 100 μL and injected in the GC(ECNI)MS. Detection limits ranged from 0.014 −1 to 0.089 pg mL−1 depending on the congener. Recoveries from real water samples, spiked at a level of 0.5 pg mL−1, ranged from 77% to 102%. The proposed method is based on the use of 81Br-labelled PBDE standards for isotope dilution analysis and the measurement of 79Br/81Br isotope ratios in gas chromatography peaks with the electron capture negative ionization sourceKeywords
This publication has 26 references indexed in Scilit:
- The determination of polybrominated diphenyl ether congeners by gas chromatography inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2008
- Analysis of polybrominated diphenyl ethers (PBDEs) by liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometry (LC/NI-APPI/MS/MS): application to house dustAnalytical and Bioanalytical Chemistry, 2008
- Headspace solid-phase microextraction with novel sol–gel permethylated-β-cyclodextrin/hydroxyl-termination silicone oil fiber for determination of polybrominated diphenyl ethers by gas chromatography–mass spectrometry in soilTalanta, 2007
- Determination of polybrominated diphenyl ethers (PBDEs) in fish samples from rivers and estuaries in TaiwanChemosphere, 2007
- Quantitative Analysis of 39 Polybrominated Diphenyl Ethers by Isotope Dilution GC/Low-Resolution MSAnalytical Chemistry, 2005
- Sample handling and analysis of brominated flame retardants in soil and sludge samplesTrAC Trends in Analytical Chemistry, 2004
- Polybrominated diphenyl ether flame retardants in the North American environmentEnvironment International, 2003
- Determination of brominated flame retardants, with emphasis on polybrominated diphenyl ethers (PBDEs) in environmental and human samples—a reviewEnvironment International, 2003
- Development and application of a method for the analysis of brominated flame retardants by fast gas chromatography with inductively coupled plasma mass spectrometric detectionJournal of Analytical Atomic Spectrometry, 2002
- Determination of Polybrominated Diphenyl Ethers and Polychlorinated Biphenyls in Human Adipose Tissue by Large-Volume Injection−Narrow-Bore Capillary Gas Chromatography/Electron Impact Low-Resolution Mass SpectrometryAnalytical Chemistry, 2002