Broken Rotor Bar Detection in Closed Loop Inverter Fed Induction Motors Through Time-Frequency Techniques
- 16 October 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 209-217
Abstract
In traction, automotive, and some industrial processes, the operation of the induction motor is set using speed. This creates an additional control loop that is external to the current controller that inverters already possess. While the impact of the latter control loop on fault detection in induction motors has already been studied, the influence of closed-loop speed control has not been explored enough. This paper presents the findings on the impact of PID speed control on the broken rotor bar fault detection. The study reveals that the constant corrective actions of the PID controller to correct the speed cause an increase in the noise level and spectral leakage around the first harmonic in the stator current spectrum that prevents fault detection. It is concluded that it is necessary to use time-frequency analysis techniques with excellent spectral resolution, such as the Dragon Transform or the Min-Norm technique.Keywords
Funding Information
- Lorenzo Mantione was supported by Erasmus+Traineeship
- Electrical Engineering Department of the University of Valladolid
- Research Group ADIRE
- ITAP Institute
This publication has 35 references indexed in Scilit:
- Effect of Magnets Asymmetry on Stray Magnetic Flux Based Bearing Damage Detection in PMSMIEEE Access, 2021
- Detection and quantification of bar breakage harmonics evolutions in inverter-fed motors through the dragon transformISA Transactions, 2021
- Diagnosis of broken rotor bar fault in open‐ and closed‐loop controlled wye‐connected induction motors using zero‐sequence voltageIET Electric Power Applications, 2017
- Quantitative broken rotor bar fault detection for closed‐loop controlled induction motorsIET Electric Power Applications, 2016
- Mixed eccentricity diagnosis in Inverter-Fed Induction Motors via the Adaptive Slope Transform of transient stator currentsMechanical Systems and Signal Processing, 2014
- Control of Electric Machine Drive Systems2010
- Sequences of field-oriented control for the detection of faulty rotor bars in induction machines-the Vienna Monitoring MethodIEEE Transactions on Industrial Electronics, 2000
- Closed-loop control impact on the diagnosis of induction motors faultsIEEE Transactions on Industry Applications, 2000
- An adaptive statistical time-frequency method for detection of broken bars and bearing faults in motors using stator currentIEEE Transactions on Industry Applications, 1999
- Internal model control: PID controller designIndustrial & Engineering Chemistry Process Design and Development, 1986