Compensating the effect of temperature variation on dielectric response of oil-paper insulation used in power transformers
- 8 September 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 23 (4) , 2462-2474
Abstract
Being an offline measurement technique, Polarization Depolarization Current (PDC) data is conventionally measured after the oil-paper insulation of the equipment reaches thermal equilibrium. Depending on the condition of the insulation, PDC data measurement time typically ranges from several minutes to few hours. It is understood that atmospheric conditions controls the value of ambient temperature. During field measurement, these conditions may not remain constant throughout the PDC recording process. Variation in ambient temperature disturbs the thermal equilibrium that the equipment may have attained at the start of the measurement procedure. Such a condition invariably affects the recorded dielectric response data. However, methods that are available for analyzing relaxation current assume that temperature equilibrium is maintained throughout the measurement period. Results presented in this paper show that dielectric response data is indeed affected if the ambient temperature increases/decreases monotonically. A method is also proposed in this paper using which the effect of such temperature variation on the recorded relaxation current data can be eliminated. This also ensures correct interpretation of PDC data for condition assessment. Analysis presented shows that the value of the equilibrium temperature does not affect the performance of the proposed technique. The applicability of the proposed methodology is first tested on laboratory samples. Thereafter, it is applied to data collected from a real life power transformer.Keywords
This publication has 29 references indexed in Scilit:
- Estimation of paper moisture content based on dielectric dissipation factor of oil-paper insulation under non-sinusoidal excitationsIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Condition assessment of cellulosic part in power transformer insulation using transfer function zero of modified debye modelIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Prediction of moisture present in cellulosic part of power transformer insulation using transfer function of modified debye modelIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- An expert system approach for transformer insulation diagnosis combining conventional diagnostic tests and PDC, RVM dataIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Effect of temperature on frequency dependent dielectric parameters of oil-paper insulation under non-sinusoidal excitationIEEE Transactions on Dielectrics and Electrical Insulation, 2014
- Assessment of non-uniform aging of solid dielectric using system poles of a modified debye model for oil-paper insulation of transformersIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- Application of S-transform for removing baseline drift from ECG2012
- Effect of thermal transient on the polarization and depolarization current measurementsIEEE Transactions on Dielectrics and Electrical Insulation, 2011
- Insulation Resistance Profile (IRP) and its use for assessing insulation systems2010
- Applications of dielectric spectroscopy in time and frequency domain for HV power equipmentIEEE Electrical Insulation Magazine, 2003