Corneal pathologies such as corneal dystrophy, keratoconus, and corneal ectasia due to surgical complications can lead to corneal deformation and tissue damage, as well as underlying changes in intrinsic corneal biomechanical properties.1,2 Detecting the changes in these biomechanical properties is an emerging method for detecting ocular diseases, monitoring disease progression, and evaluating therapies because it is postulated that changes in tissue biomechanical properties can preclude structural or functional changes.3 Noncontact applanation tonometers such as the CorVis ST (OCULUS Optikgerate GmbH, Germany) and the ORA (Reichert Technologies, USA) have long been being used to measure corneal biomechanical properties by analyzing the response of the cornea to a large burst of air (inducing displacement of mm-scale). However, these methods have had conflicting results in measuring mechanical property changes because separating the effects from corneal geometry, biomechanical properties, and intraocular pressure (IOP) is a complex problem that is currently under investigation.4 – 8 Brillouin microscopy has also been effective in assessing the mechanical properties of the cornea indirectly,9,10 but spatial assessment of tissue elasticity may require long imaging times (∼50  s for a cross sectional scan11), and quantification of material parameters (e.g., Young’s modulus) from the Brillouin frequency shift is still an open question.12 In contrast, elastography has rapidly been growing since its inception in the 90s as a quantitative technique for measuring tissue biomechanical properties. In elastography, tissue motion is measured using an imaging modality,13,14 and then material parameters (e.g., Young’s modulus) are estimated by appropriate mechanical models. Ultrasound elastography and optical coherence elastography (OCE) have been previously utilized to assess the mechanical properties of the cornea.8,15 – 18 Typically, these techniques measure the corneal response to different external forces.19 – 23 However, there is growing interest in assessing the tissue mechanical response to intrinsic physiological forces.24 For example, hemodynamics within the eyeball can cause ocular tissue to experience pulsatile motion known as the ocular pulse. In other words, the ocular pulse is the difference between systolic and diastolic IOP. This pulse is highly correlated with biomechanical properties of the eye, and distinguishing changes in tissue during the various phases of the pulse may reveal important information about biomechanical properties of ocular tissues.25 Diffuse shear wave imaging that measured tissue response to muscular activity and the heartbeat has been demonstrated in an in vivo rat eye model.26 However, this noise correlation technique may not necessarily distinguish stiffness across different ocular tissues. Recently, ultrasound elastography has been used to measure the corneal biomechanical response to simulated quasi-static IOP fluctuations, but this method is limited by the resolution of its parent imaging modality.27,28 OCE has been utilized to measure the corneal response to slow diurnal fluctuations in IOP with a higher resolution. However, the ocular pulse and subsequent displacements in the cornea that occur at the heart rate are much faster than diurnal fluctuations and could be utilized to assess dynamic physiological pressures on the cornea.29 – 31 By taking advantage of the physiological forces applied to the corneal tissue, it is possible to assess the biomechanical properties of the cornea using only an OCT system, which is ubiquitous in ophthalmic clinics now. In this work, we introduce heartbeat OCE (Hb-OCE) to assess the corneal biomechanical response to varying fluctuations in IOP that simulate the heartbeat-induced ocular pulse in an ex vivo porcine cornea model. Furthermore, this technique was used to distinguish tissue stiffness between normal and crosslinked (CXL) corneas.
Funding Information
  • National Institutes of Health (R01EY022362)
  • National Institutes of Health (P30EY007551)
  • National Institutes of Health (T15LM007093)

This publication has 55 references indexed in Scilit: