Achuth Nair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Achuth Nair has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Kirill V. Larin
Department of Biomedical Engineering, University of Houston, Houston, Texas, United States
8 shared publications - Manmohan Singh
Department of Biomedical Engineering University of Houston Houston Texas USA
8 shared publications - Salavat R. Aglyamov
University of Houston
6 shared publications Chen Wu
Univ. of Houston
2 shared publications- Zhaolong Han
School of Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications Alexander Schill
Univ. of Houston
1 shared publication
Latest Publications
- Open Access
- 11 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (12) , 1-10
Optical coherence elastography detects increased corneal stiffness in nonhuman primates with experimental glaucoma
SignificanceGlaucoma is a leading cause of irreversible blindness, characterized by progressive optic nerve damage. Early detection of glaucoma is key to effective intervention, but an incomplete clinical understanding of the development of glaucoma complicates the selection of diagnostic criteria. Prolonged ocular hypertension due to glaucoma can impact the biomechanical properties of ocular tissues, including the cornea. We examine whether experimental glaucoma causes changes in the biomechanical properties of the cornea.AimWe determined the biomechanical properties of the cornea in a nonhuman primate model of unilateral experimental glaucoma and compared them with the fellow, untreated control eyes using optical coherence elastography (OCE) to determine if prolonged intraocular pressure (IOP) elevation causes changes in corneal stiffness.ApproachExperimental glaucoma was induced in one eye (Macaca mulatta, N=2) by lasering the trabecular meshwork, whereas the fellow eye was used as a control. Both eyes were imaged with wave-based OCE to investigate the inter-ocular difference in stiffness. Measurements were taken at three different frequencies with quasi-harmonic excitation, and central corneal thickness was measured along with IOP in each eye.ResultsOur results show a significant (p<0.01) increase in wave speed in the experimental glaucoma eye compared with the control eye for both subjects.ConclusionsThese results show the potential of wave-based OCE methods for assessing stiffness changes in the cornea caused by remodeling due to chronic pressure elevation.
- 11 October 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (12) , 1-10
Open AccessOptical coherence elastography detects increased corneal stiffness in nonhuman primates with experimental glaucoma
SignificanceGlaucoma is a leading cause of irreversible blindness, characterized by progressive optic nerve damage. Early detection of glaucoma is key to effective intervention, but an incomplete clinical understanding of the development of glaucoma complicates the selection of diagnostic criteria. Prolonged ocular hypertension due to glaucoma can impact the biomechanical properties of ocular tissues, including the cornea. We examine whether experimental glaucoma causes changes in the biomechanical properties of the cornea.AimWe determined the biomechanical properties of the cornea in a nonhuman primate model of unilateral experimental glaucoma and compared them with the fellow, untreated control eyes using optical coherence elastography (OCE) to determine if prolonged intraocular pressure (IOP) elevation causes changes in corneal stiffness.ApproachExperimental glaucoma was induced in one eye (Macaca mulatta, N=2) by lasering the trabecular meshwork, whereas the fellow eye was used as a control. Both eyes were imaged with wave-based OCE to investigate the inter-ocular difference in stiffness. Measurements were taken at three different frequencies with quasi-harmonic excitation, and central corneal thickness was measured along with IOP in each eye.ResultsOur results show a significant (p<0.01) increase in wave speed in the experimental glaucoma eye compared with the control eye for both subjects.ConclusionsThese results show the potential of wave-based OCE methods for assessing stiffness changes in the cornea caused by remodeling due to chronic pressure elevation.
- Open Access
- 1 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 095002-13
Dual optical elastography detects TGF-β-induced alterations in the biomechanical properties of skin scaffolds
The skin features an inherent structure that provides strength and flexibility, functioning as a protective shield for softer, deeper tissues. The skin is subject to forces arising from body mechanics, such as joint movements and muscle contractions, as well as external factors, including physical insults and surgeries. Thus, the skin should be able to withstand applied forces (tensile strength), stretch without losing its structural integrity (extensibility), recoil back to its original form (elasticity), and regenerate original properties following an injury to maintain proper body functions.1 Nonetheless, dermal biomechanical properties may be compromised by various factors, such as aging 2 and disease,3 potentially impeding its optimal function. Therefore, understanding the alterations in the biomechanical properties of the skin is crucial in tissue engineering and regenerative medicine, particularly in designing effective skin substitutes and enhancing the success rates of skin grafts.
- 1 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 095002-13
Open AccessDual optical elastography detects TGF-β-induced alterations in the biomechanical properties of skin scaffolds
The skin features an inherent structure that provides strength and flexibility, functioning as a protective shield for softer, deeper tissues. The skin is subject to forces arising from body mechanics, such as joint movements and muscle contractions, as well as external factors, including physical insults and surgeries. Thus, the skin should be able to withstand applied forces (tensile strength), stretch without losing its structural integrity (extensibility), recoil back to its original form (elasticity), and regenerate original properties following an injury to maintain proper body functions.1 Nonetheless, dermal biomechanical properties may be compromised by various factors, such as aging 2 and disease,3 potentially impeding its optimal function. Therefore, understanding the alterations in the biomechanical properties of the skin is crucial in tissue engineering and regenerative medicine, particularly in designing effective skin substitutes and enhancing the success rates of skin grafts.
- Open Access
Compressional Optical Coherence Elastography of the Cornea
Assessing the biomechanical properties of the cornea is crucial for detecting the onset and progression of eye diseases. In this work, we demonstrate the application of compression-based optical coherence elastography (OCE) to measure the biomechanical properties of the cornea under various conditions, including validation in an in situ rabbit model and a demonstration of feasibility for in vivo measurements. Our results show a stark increase in the stiffness of the corneas as IOP was increased. Moreover, UV-A/riboflavin corneal collagen crosslinking (CXL) also dramatically increased the stiffness of the corneas. The results were consistent across 4 different scenarios (whole CXL in situ, partial CXL in situ, whole CXL in vivo, and partial CXL in vivo), emphasizing the reliability of compression OCE to measure corneal biomechanical properties and its potential for clinical applications.
Open AccessCompressional Optical Coherence Elastography of the Cornea
Assessing the biomechanical properties of the cornea is crucial for detecting the onset and progression of eye diseases. In this work, we demonstrate the application of compression-based optical coherence elastography (OCE) to measure the biomechanical properties of the cornea under various conditions, including validation in an in situ rabbit model and a demonstration of feasibility for in vivo measurements. Our results show a stark increase in the stiffness of the corneas as IOP was increased. Moreover, UV-A/riboflavin corneal collagen crosslinking (CXL) also dramatically increased the stiffness of the corneas. The results were consistent across 4 different scenarios (whole CXL in situ, partial CXL in situ, whole CXL in vivo, and partial CXL in vivo), emphasizing the reliability of compression OCE to measure corneal biomechanical properties and its potential for clinical applications.
- Open Access
- 23 February 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (02) , 020502-8
Heartbeat optical coherence elastography: corneal biomechanics in vivo
The cornea is an essential component of vision, and various pathologies, such as keratoconus and corneal ectasia, can affect its structural integrity and biomechanical properties.1,2 One emerging method for assessing these biomechanical changes in corneal tissue is utilizing noncontact tonometry, such as with the CorVis ST (OCULUS Optikgerate GmbH, Germany) and ORA (Reichert Technologies). While these tools are useful in the clinic, separating the effects of stiffness, intraocular pressure (IOP), and corneal geometry with these devices is a complex problem that is still under investigation.3 – 7
- 23 February 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (02) , 020502-8
Open AccessHeartbeat optical coherence elastography: corneal biomechanics in vivo
The cornea is an essential component of vision, and various pathologies, such as keratoconus and corneal ectasia, can affect its structural integrity and biomechanical properties.1,2 One emerging method for assessing these biomechanical changes in corneal tissue is utilizing noncontact tonometry, such as with the CorVis ST (OCULUS Optikgerate GmbH, Germany) and ORA (Reichert Technologies). While these tools are useful in the clinic, separating the effects of stiffness, intraocular pressure (IOP), and corneal geometry with these devices is a complex problem that is still under investigation.3 – 7
- Open Access
- 5 May 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 25 (05) , 055001-9
Heartbeat OCE: corneal biomechanical response to simulated heartbeat pulsation measured by optical coherence elastography
Corneal pathologies such as corneal dystrophy, keratoconus, and corneal ectasia due to surgical complications can lead to corneal deformation and tissue damage, as well as underlying changes in intrinsic corneal biomechanical properties.1,2 Detecting the changes in these biomechanical properties is an emerging method for detecting ocular diseases, monitoring disease progression, and evaluating therapies because it is postulated that changes in tissue biomechanical properties can preclude structural or functional changes.3 Noncontact applanation tonometers such as the CorVis ST (OCULUS Optikgerate GmbH, Germany) and the ORA (Reichert Technologies, USA) have long been being used to measure corneal biomechanical properties by analyzing the response of the cornea to a large burst of air (inducing displacement of mm-scale). However, these methods have had conflicting results in measuring mechanical property changes because separating the effects from corneal geometry, biomechanical properties, and intraocular pressure (IOP) is a complex problem that is currently under investigation.4 – 8 Brillouin microscopy has also been effective in assessing the mechanical properties of the cornea indirectly,9,10 but spatial assessment of tissue elasticity may require long imaging times ( for a cross sectional scan11), and quantification of material parameters (e.g., Young’s modulus) from the Brillouin frequency shift is still an open question.12 In contrast, elastography has rapidly been growing since its inception in the 90s as a quantitative technique for measuring tissue biomechanical properties. In elastography, tissue motion is measured using an imaging modality,13,14 and then material parameters (e.g., Young’s modulus) are estimated by appropriate mechanical models. Ultrasound elastography and optical coherence elastography (OCE) have been previously utilized to assess the mechanical properties of the cornea.8,15 – 18 Typically, these techniques measure the corneal response to different external forces.19 – 23 However, there is growing interest in assessing the tissue mechanical response to intrinsic physiological forces.24 For example, hemodynamics within the eyeball can cause ocular tissue to experience pulsatile motion known as the ocular pulse. In other words, the ocular pulse is the difference between systolic and diastolic IOP. This pulse is highly correlated with biomechanical properties of the eye, and distinguishing changes in tissue during the various phases of the pulse may reveal important information about biomechanical properties of ocular tissues.25 Diffuse shear wave imaging that measured tissue response to muscular activity and the heartbeat has been demonstrated in an in vivo rat eye model.26 However, this noise correlation technique may not necessarily distinguish stiffness across different ocular tissues. Recently, ultrasound elastography has been used to measure the corneal biomechanical response to simulated quasi-static IOP fluctuations, but this method is limited by the resolution of its parent imaging modality.27,28 OCE has been utilized to measure the corneal response to slow diurnal fluctuations in IOP with a higher resolution. However, the ocular pulse and subsequent displacements in the cornea that occur at the heart rate are much faster than diurnal fluctuations and could be utilized to assess dynamic physiological pressures on the cornea.29 – 31 By taking advantage of the physiological forces applied to the corneal tissue, it is possible to assess the biomechanical properties of the cornea using only an OCT system, which is ubiquitous in ophthalmic clinics now. In this work, we introduce heartbeat OCE (Hb-OCE) to assess the corneal biomechanical response to varying fluctuations in IOP that simulate the heartbeat-induced ocular pulse in an ex vivo porcine cornea model. Furthermore, this technique was used to distinguish tissue stiffness between normal and crosslinked (CXL) corneas.- 5 May 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 25 (05) , 055001-9
Open AccessHeartbeat OCE: corneal biomechanical response to simulated heartbeat pulsation measured by optical coherence elastography
Corneal pathologies such as corneal dystrophy, keratoconus, and corneal ectasia due to surgical complications can lead to corneal deformation and tissue damage, as well as underlying changes in intrinsic corneal biomechanical properties.1,2 Detecting the changes in these biomechanical properties is an emerging method for detecting ocular diseases, monitoring disease progression, and evaluating therapies because it is postulated that changes in tissue biomechanical properties can preclude structural or functional changes.3 Noncontact applanation tonometers such as the CorVis ST (OCULUS Optikgerate GmbH, Germany) and the ORA (Reichert Technologies, USA) have long been being used to measure corneal biomechanical properties by analyzing the response of the cornea to a large burst of air (inducing displacement of mm-scale). However, these methods have had conflicting results in measuring mechanical property changes because separating the effects from corneal geometry, biomechanical properties, and intraocular pressure (IOP) is a complex problem that is currently under investigation.4 – 8 Brillouin microscopy has also been effective in assessing the mechanical properties of the cornea indirectly,9,10 but spatial assessment of tissue elasticity may require long imaging times ( for a cross sectional scan11), and quantification of material parameters (e.g., Young’s modulus) from the Brillouin frequency shift is still an open question.12 In contrast, elastography has rapidly been growing since its inception in the 90s as a quantitative technique for measuring tissue biomechanical properties. In elastography, tissue motion is measured using an imaging modality,13,14 and then material parameters (e.g., Young’s modulus) are estimated by appropriate mechanical models. Ultrasound elastography and optical coherence elastography (OCE) have been previously utilized to assess the mechanical properties of the cornea.8,15 – 18 Typically, these techniques measure the corneal response to different external forces.19 – 23 However, there is growing interest in assessing the tissue mechanical response to intrinsic physiological forces.24 For example, hemodynamics within the eyeball can cause ocular tissue to experience pulsatile motion known as the ocular pulse. In other words, the ocular pulse is the difference between systolic and diastolic IOP. This pulse is highly correlated with biomechanical properties of the eye, and distinguishing changes in tissue during the various phases of the pulse may reveal important information about biomechanical properties of ocular tissues.25 Diffuse shear wave imaging that measured tissue response to muscular activity and the heartbeat has been demonstrated in an in vivo rat eye model.26 However, this noise correlation technique may not necessarily distinguish stiffness across different ocular tissues. Recently, ultrasound elastography has been used to measure the corneal biomechanical response to simulated quasi-static IOP fluctuations, but this method is limited by the resolution of its parent imaging modality.27,28 OCE has been utilized to measure the corneal response to slow diurnal fluctuations in IOP with a higher resolution. However, the ocular pulse and subsequent displacements in the cornea that occur at the heart rate are much faster than diurnal fluctuations and could be utilized to assess dynamic physiological pressures on the cornea.29 – 31 By taking advantage of the physiological forces applied to the corneal tissue, it is possible to assess the biomechanical properties of the cornea using only an OCT system, which is ubiquitous in ophthalmic clinics now. In this work, we introduce heartbeat OCE (Hb-OCE) to assess the corneal biomechanical response to varying fluctuations in IOP that simulate the heartbeat-induced ocular pulse in an ex vivo porcine cornea model. Furthermore, this technique was used to distinguish tissue stiffness between normal and crosslinked (CXL) corneas. - Open Access
- 12 March 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (03) , 036004-7
Optical coherence elastography of cold cataract in porcine lens
Cataract is clouding of the crystalline lens that can severely impair vision with faded colors, blurry vision, halos around light, and poor night vision. Approximately one-third of all people with some form of vision impairment have cataract.1 Eventually, over half of patients with cataract undergo vision loss.1 There are numerous causes of cataract, such as aging, trauma, diabetes, obesity, congenital genetic deficiencies, and environmental exposure to toxins.2 Usually, cataract is progressive and requires surgical interventions for treatment. The specific underlying mechanism of cataract formation is still unknown, but there are reports that the stiffness of the cataract lenses in humans is significantly higher than that of normal lenses.3
- 12 March 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (03) , 036004-7
Open AccessOptical coherence elastography of cold cataract in porcine lens
Cataract is clouding of the crystalline lens that can severely impair vision with faded colors, blurry vision, halos around light, and poor night vision. Approximately one-third of all people with some form of vision impairment have cataract.1 Eventually, over half of patients with cataract undergo vision loss.1 There are numerous causes of cataract, such as aging, trauma, diabetes, obesity, congenital genetic deficiencies, and environmental exposure to toxins.2 Usually, cataract is progressive and requires surgical interventions for treatment. The specific underlying mechanism of cataract formation is still unknown, but there are reports that the stiffness of the cataract lenses in humans is significantly higher than that of normal lenses.3
- 20 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (02) , 020502
Applanation optical coherence elastography: noncontact measurement of intraocular pressure, corneal biomechanical properties, and corneal geometry with a single instrument
Current clinical tools provide critical information about ocular health such as intraocular pressure (IOP). However, they lack the ability to quantify tissue material properties, which are potent markers for ocular tissue health and integrity. We describe a single instrument to measure the eye-globe IOP, quantify corneal biomechanical properties, and measure corneal geometry with a technique termed applanation optical coherence elastography (Appl-OCE). An ultrafast OCT system enabled visualization of corneal dynamics during noncontact applanation tonometry and direct measurement of micro air-pulse induced elastic wave propagation. Our preliminary results show that the proposed Appl-OCE system can be used to quantify IOP, corneal biomechanical properties, and corneal geometry, which builds a solid foundation for a unique device that can provide a more complete picture of ocular health.
- 20 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (02) , 020502
Applanation optical coherence elastography: noncontact measurement of intraocular pressure, corneal biomechanical properties, and corneal geometry with a single instrument
Current clinical tools provide critical information about ocular health such as intraocular pressure (IOP). However, they lack the ability to quantify tissue material properties, which are potent markers for ocular tissue health and integrity. We describe a single instrument to measure the eye-globe IOP, quantify corneal biomechanical properties, and measure corneal geometry with a technique termed applanation optical coherence elastography (Appl-OCE). An ultrafast OCT system enabled visualization of corneal dynamics during noncontact applanation tonometry and direct measurement of micro air-pulse induced elastic wave propagation. Our preliminary results show that the proposed Appl-OCE system can be used to quantify IOP, corneal biomechanical properties, and corneal geometry, which builds a solid foundation for a unique device that can provide a more complete picture of ocular health.
- Open Access
- 1 September 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (9) , 090504
Quantifying tissue viscoelasticity using optical coherence elastography and the Rayleigh wave model
This study demonstrates the feasibility of using the Rayleigh wave model (RWM) in combination with optical coherence elastography (OCE) technique to assess the viscoelasticity of soft tissues. Dispersion curves calculated from the spectral decomposition of OCE-measured air-pulse induced elastic waves were used to quantify the viscoelasticity of samples using the RWM. Validation studies were first conducted on 10% gelatin phantoms with different concentrations of oil. The results showed that the oil increased the viscosity of the gelatin phantom samples. This method was then used to quantify the viscoelasticity of chicken liver. The Young’s modulus of the chicken liver tissues was estimated as with a shear viscosity . The analytical solution of the RWM correlated very well with the OCE-measured phased velocities (). The results show that the combination of the RWM and OCE is a promising method for noninvasively quantifying the biomechanical properties of soft tissues and may be a useful tool for detecting disease.- 1 September 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (9) , 090504
Open AccessQuantifying tissue viscoelasticity using optical coherence elastography and the Rayleigh wave model
This study demonstrates the feasibility of using the Rayleigh wave model (RWM) in combination with optical coherence elastography (OCE) technique to assess the viscoelasticity of soft tissues. Dispersion curves calculated from the spectral decomposition of OCE-measured air-pulse induced elastic waves were used to quantify the viscoelasticity of samples using the RWM. Validation studies were first conducted on 10% gelatin phantoms with different concentrations of oil. The results showed that the oil increased the viscosity of the gelatin phantom samples. This method was then used to quantify the viscoelasticity of chicken liver. The Young’s modulus of the chicken liver tissues was estimated as with a shear viscosity . The analytical solution of the RWM correlated very well with the OCE-measured phased velocities (). The results show that the combination of the RWM and OCE is a promising method for noninvasively quantifying the biomechanical properties of soft tissues and may be a useful tool for detecting disease.