Surface guided imaging during stereotactic radiosurgery with automated delivery
Open Access
- 23 October 2020
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (12) , 90-95
Abstract
Purpose: To report on the use of surface guided imaging during frameless intracranial stereotactic radiotherapy with automated delivery via HyperArcTM (Varian Medical Systems, Palo Alto, CA).Methods: All patients received intracranial radiotherapy with HyperArcTM and were monitored for intrafraction motion by the AlignRT® (VisionRT, London, UK) surface imaging (SI) system. Immobilization was with the EncompassTM (Qfix, Avondale, PA) aquaplast mask device. AlignRT® log files were correlated with trajectory log files to correlate treatment parameters with SI reported offsets. SI reported offsets were correlated with gantry angle and analyzed for performance issues at non‐zero couch angles and during camera‐pod blockage during gantry motion. Demographics in the treatment management system were used to identify race and determine if differences in SI reported offsets are due to skin tone settings.Results: A total of 981 fractions were monitored over 14 months and 819 were analyzed. The median AlignRT® reported motion from beginning to the end of treatment was 0.24 mm. The median offset before beam on at non‐zero couch angles was 0.55 mm. During gantry motion when camera pods are blocked, the median magnitude was below 1 mm. Median magnitude of offsets at non‐zero couch angles was not found to be significantly different for patients stratified by race.Conclusions: Surface image guidance is a viable alternative to scheduled mid‐treatment imaging for monitoring intrafraction motion during stereotactic radiosurgery with automated delivery.Keywords
This publication has 17 references indexed in Scilit:
- Assessment of interfractional variation of the breast surface following conventional patient positioning for whole‐breast radiotherapyJournal of Applied Clinical Medical Physics, 2014
- Evaluation of radiotherapy setup accuracy for head and neck cancer using a 3-D surface imaging systemJournal of Instrumentation, 2013
- Spatial and temporal performance of 3D optical surface imaging for real‐time head position trackingMedical Physics, 2013
- A comparison of patient position displacements from body surface laser scanning and cone beam CT bone registrations for radiotherapy of pelvic targetsActa Oncologica, 2013
- Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Clinical evaluation of interfractional variations for whole breast radiotherapy using 3-dimensional surface imagingPractical Radiation Oncology, 2013
- Frameless, Real-Time, Surface Imaging-Guided RadiosurgeryNeurosurgery, 2012
- Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatmentPractical Radiation Oncology, 2012
- Motion monitoring for cranial frameless stereotactic radiosurgery using video‐based three‐dimensional optical surface imagingMedical Physics, 2011
- Real‐time 3D‐surface‐guided head refixation useful for fractionated stereotactic radiotherapyMedical Physics, 2006