Imaging of vaporised sub-micron phase change contrast agents with high frame rate ultrasound and optics
- 1 March 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (6) , 065002
Abstract
Phase-change ultrasound contrast agent (PCCA), or nanodroplet, shows promise as an alternative to the conventional microbubble agent over a wide range of diagnostic applications. Meanwhile, high-frame-rate (HFR) ultrasound imaging with microbubbles enables unprecedented temporal resolution compared to traditional contrast-enhanced ultrasound imaging. The combination of HFR ultrasound imaging and PCCAs can offer the opportunity to observe and better understand PCCA behaviour after vaporisation captures the fast phenomenon at a high temporal resolution. In this study, we utilised HFR ultrasound at frame rates in the kilohertz range (5–20 kHz) to image native and size-selected PCCA populations immediately after vaporisation in vitro within clinical acoustic parameters. The size-selected PCCAs through filtration are shown to preserve a sub-micron-sized (mean diameter < 200 nm) population without micron-sized outliers (>1 µ m) that originate from native PCCA emulsion. The results demonstrate imaging signals with different amplitudes and temporal features compared to that of microbubbles. Compared with the microbubbles, both the B-mode and pulse-inversion (PI) signals from the vaporised PCCA populations were reduced significantly in the first tens of milliseconds, while only the B-mode signals from the PCCAs were recovered during the next 400 ms, suggesting significant changes to the size distribution of the PCCAs after vaporisation. It is also shown that such recovery in signal over time is not evident when using size-selective PCCAs. Furthermore, it was found that signals from the vaporised PCCA populations are affected by the amplitude and frame rate of the HFR ultrasound imaging. Using high-speed optical camera observation (30 kHz), we observed a change in particle size in the vaporised PCCA populations exposed to the HFR ultrasound imaging pulses. These findings can further the understanding of PCCA behaviour under HFR ultrasound imaging.Keywords
This publication has 49 references indexed in Scilit:
- 3-D In Vitro Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using MicrobubblesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2017
- Acoustic Behavior of a Reactivated, Commercially Available Ultrasound Contrast AgentJournal of the American Society of Echocardiography, 2017
- The lifetime evaluation of vapourised phase-change nano-dropletsUltrasonics, 2016
- Ultrafast ultrasound localization microscopy for deep super-resolution vascular imagingNature, 2015
- Shaken and Stirred: Mechanisms of Ultrasound-Enhanced ThrombolysisUltrasound in Medicine & Biology, 2015
- Ultrasound contrast plane wave imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- Ultrasound internal tattooingMedical Physics, 2011
- Measuring the Hydrodynamic Size of Nanoparticles in Aqueous Media Using Batch-Mode Dynamic Light Scattering2010
- In vitrocharacterization of the subharmonic ultrasound signal from Definity microbubbles at high frequenciesPhysics in Medicine & Biology, 2008
- Microbubble oscillation in tubes with diameters of 12, 25, and 195 micronsApplied Physics Letters, 2006