CLChee Hau Leow

Chee Hau Leow

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chee Hau Leow has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Contrast-Enhanced High-Frame-Rate Ultrasound Imaging of Flow Patterns in Cardiac Chambers and Deep Vessels

    by Hendrik J. Vos, Jason D. Voorneveld, Erik Groot Jebbink, Chee Hau Leow, Luzhen Nie, Annemien E. van Den Bosch, Meng-Xing Tang, Steven Freear, Johan G. Bosch


  • Open Access

    Minimization of Nanodroplet Activation Time using Focused-Pulses for Droplet-Based Ultrasound Super-Resolution Imaging

    by Ge Zhang, Sevan Harput, Jiaqi Zhu, Kirsten Christensen-Jeffries, Jemma Brown, Chee Hau Leow, Chris Dunsby, Robert J. Eckersley, Meng-Xing Tang

    One of the crucial challenges in the application of ultrasound super-resolution imaging using microbubble contrast agents to the clinic is the long acquisition time. Recently acoustic wave sparsely activated localization microscopy (AWSALM) was developed to activate, image, and destroy nanodroplets to achieve ultrasound super-resolution imaging. The activation and destruction of nanodroplets using focused pulses in AWSALM can generate new localization signals without relying on flow and shows the potential to achieve faster ultrasound super-resolution. However, the technique requires optimization to achieve good activation efficiency with the minimum amount of activation time.This work investigates how the different activation strategies affect the activation time and efficiency. A range of activation sequences with different F-numbers and spacing between transmit foci are used and their activation efficiency and the data acquisition time are quantified. The results show that sweeping the focus of the activation pulse with an F-number of 0.4 and a step size of 2.5 wavelengths can generate the highest droplet activation. By using a larger or smaller spacing between consecutive focused activation beams generated lower contrast, which suggests that densely spaced activation pulses may destroy the activated nanodroplets generated by the previous activation pulse. In summary, this study demonstrates that the rate of activation of nanodroplets can be increased by optimizing the F-number and the sweep step size. This finding can inform the development of droplet-based super-resolution imaging to further minimize the data acquisition time.


  • Open Access

    3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array

    by Sevan Harput, Kirsten Christensen-Jeffries, Alessandro Ramalli, Jemma Brown, Jiaqi Zhu, Ge Zhang, Chee Hau Leow, Matthieu Toulemonde, Enrico Boni, Piero Tortoli, et al.

    High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.


  • Quantification of Vaporised Targeted Nanodroplets Using High-Frame-Rate Ultrasound and Optics

    by Ge Zhang, Shengtao Lin, Chee Hao Leow, Kuin Tian Pang, Javier Hernández-Gil, Nicholas J. Long, Robert Eckersley, Terry Matsunaga, Meng-Xing Tang


  • Open Access

    Fast Acoustic Wave Sparsely Activated Localization Microscopy: Ultrasound Super-Resolution Using Plane-Wave Activation of Nanodroplets

    by Ge Zhang, Sevan Harput, Hanyu Hu, Kirsten Christensen-Jeffries, Jiaqi Zhu, Jemma Brown, Chee Hau Leow, Robert J. Eckersley, Christopher Dunsby, Meng-Xing Tang

    Localization-based ultrasound super-resolution imaging using microbubble contrast agents and phase-change nano-droplets has been developed to visualize microvascular structures beyond the diffraction limit. However, the long data acquisition time makes the clinical translation more challenging. In this study, fast acoustic wave sparsely activated localization microscopy (fast-AWSALM) was developed to achieve super-resolved frames with sub-second temporal resolution, by using low-boiling-point octafluoropropane nanodroplets and high frame rate plane waves for activation, destruction, as well as imaging. Fast-AWSALM was demonstrated on an in vitro microvascular phantom to super-resolve structures that could not be resolved by conventional B-mode imaging. The effects of the temperature and mechanical index on fast-AWSALM was investigated. Experimental results show that sub-wavelength micro-structures as small as 190 lm were resolvable in 200 ms with plane-wave transmission at a center frequency of 3.5 MHz and a pulse repetition frequency of 5000 Hz. This is about a 3.5 fold reduction in point spread function full-width-half-maximum compared to that measured in conventional B-mode, and two orders of magnitude faster than the recently reported AWSALM under a non-flow/very slow flow situations and other localization based methods. Just as in AWSALM, fast-AWSALM does not require flow, as is required by current microbubble based ultrasound super resolution techniques. In conclusion, this study shows the promise of fast-AWSALM, a super-resolution ultrasound technique using nanodroplets, which can generate super-resolution images in milli-seconds and does not require flow.


  • Open Access

    3-D Microvascular Imaging Using High Frame Rate Ultrasound and ASAP Without Contrast Agents: Development and Initial In Vivo Evaluation on Nontumor and Tumor Models

    by Chee Hau Leow, Nigel L. Bush, Antonio Stanziola, Marta Braga, Anant Shah, Javier Hernandez-Gil, Nicholas J. Long, Eric O. Aboagye, Jeffrey C. Bamber, Meng-Xing Tang

    Three-dimensional imaging is valuable to noninvasively assess angiogenesis given the complex 3-D architecture of vascular networks. The emergence of high frame rate (HFR) ultrasound, which can produce thousands of images per second, has inspired novel signal processing techniques and their applications in structural and functional imaging of blood vessels. Although highly sensitive vascular mapping has been demonstrated using ultrafast Doppler, the detectability of microvasculature from the background noise may be hindered by the low signal-to-noise ratio (SNR) particularly in the deeper region and without the use of contrast agents. We have recently demonstrated a coherence-based technique, acoustic subaperture imaging (ASAP), for super-contrast vascular imaging and illustrated the contrast improvement using HFR contrast-enhanced ultrasound. In this work, we provide a feasibility study for microvascular imaging using ASAP without contrast agents, and extend its capability from 2-D to volumetric vascular mapping. Using an ultrasound research system and a preclinical probe, we demonstrated the improved visibility of microvascular mapping using ASAP in comparison to ultrafast power Doppler (PD) on a mouse kidney, liver, and tumor without contrast agent injection. The SNR of ASAP images improves in average by 10 dB when compared to PD. In addition, directional velocity mappings were also demonstrated by combining ASAP with the phase information extracted from lag-1 autocorrelation. The 3-D vascular and velocity mapping of the mouse kidney, liver, and tumor were demonstrated by stacking the ASAP images acquired using 2-D ultrasound imaging and a trigger-controlled linear translation stage. The 3-D results depicted clear microvasculature morphologies and functional information in terms of flow direction and velocity in two nontumor models and a tumor model. In conclusion, we have demonstrated a new 3-D in vivo ultrasound microvascular imaging technique with significantly improved SNR over existing ultrafast Doppler.


  • Open Access

    3-D Velocity and Volume Flow Measurement $In~Vivo$ Using Speckle Decorrelation and 2-D High-Frame-Rate Contrast-Enhanced Ultrasound

    by Xiaowei Zhou, Chee Hau Leow, Ethan Rowland, Kai Riemer, Jonathan M. Rubin, Peter D. Weinberg, Meng-Xing Tang

    Being able to measure 3D flow velocity and volumetric flow rate effectively in the cardiovascular system is valuable but remains a significant challenge in both clinical practice and research. Currently there has not been an effective and practical solution to the measurement of volume flow using ultrasound imaging systems due to challenges in existing 3D imaging techniques and high system cost. In this study, a new technique for quantifying volumetric flow rate from the crosssectional imaging plane of the blood vessel was developed by using speckle decorrelation, 2D high frame rate imaging with a standard 1D array transducer, microbubble contrast agents, and ultrasound imaging velocimetry (UIV). Through speckle decorrelation analysis of microbubble signals acquired with a very high frame rate and by using UIV to estimate the two in-plane flow velocity components, the third and out-of-plane velocity component can be obtained over time and integrated to estimate volume flow. The proposed technique was evaluated on a wall-less flow phantom in both steady and pulsatile flow. UIV in the longitudinal direction was conducted as a reference. The influences of frame rate, mechanical index, orientation of imaging plane, and compounding on velocity estimation were also studied. In addition, an in vivo trial on the abdominal aorta of a rabbit was conducted. The results show that the new system can estimate volume flow with an averaged error of 3.65±2.37% at a flow rate of 360 ml/min and a peak velocity of 0.45 m/s, and an error of 5.03±2.73% at a flow rate of 723 ml/min and a peak velocity of 0.8 m/s. The accuracy of the flow velocity and volumetric flow rate estimation directly depend on the imaging frame rate. With a frame rate of 6000 Hz, a velocity up to 0.8 m/s can be correctly estimated. A higher mechanical index (MI=0.42) is shown to produce greater errors (up to 21.78±0.49%, compared to 3.65±2.37% at MI=0.19). An in vivo trial, where velocities up to 1 m/s were correctly measured, demonstrated the potential of the technique in clinical applications.


  • Imaging of vaporised sub-micron phase change contrast agents with high frame rate ultrasound and optics

    by Shengtao Lin, Ge Zhang, Akaki Jamburidze, Melisse Chee, Chee Hau Leow, Valeria Garbin, Meng-Xing Tang

    Phase-change ultrasound contrast agent (PCCA), or nanodroplet, shows promise as an alternative to the conventional microbubble agent over a wide range of diagnostic applications. Meanwhile, high-frame-rate (HFR) ultrasound imaging with microbubbles enables unprecedented temporal resolution compared to traditional contrast-enhanced ultrasound imaging. The combination of HFR ultrasound imaging and PCCAs can offer the opportunity to observe and better understand PCCA behaviour after vaporisation captures the fast phenomenon at a high temporal resolution. In this study, we utilised HFR ultrasound at frame rates in the kilohertz range (5–20 kHz) to image native and size-selected PCCA populations immediately after vaporisation in vitro within clinical acoustic parameters. The size-selected PCCAs through filtration are shown to preserve a sub-micron-sized (mean diameter < 200 nm) population without micron-sized outliers (>1 µ m) that originate from native PCCA emulsion. The results demonstrate imaging signals with different amplitudes and temporal features compared to that of microbubbles. Compared with the microbubbles, both the B-mode and pulse-inversion (PI) signals from the vaporised PCCA populations were reduced significantly in the first tens of milliseconds, while only the B-mode signals from the PCCAs were recovered during the next 400 ms, suggesting significant changes to the size distribution of the PCCAs after vaporisation. It is also shown that such recovery in signal over time is not evident when using size-selective PCCAs. Furthermore, it was found that signals from the vaporised PCCA populations are affected by the amplitude and frame rate of the HFR ultrasound imaging. Using high-speed optical camera observation (30 kHz), we observed a change in particle size in the vaporised PCCA populations exposed to the HFR ultrasound imaging pulses. These findings can further the understanding of PCCA behaviour under HFR ultrasound imaging.


  • Open Access

    ASAP: Super-Contrast Vasculature Imaging Using Coherence Analysis and High Frame-Rate Contrast Enhanced Ultrasound

    by Antonio Stanziola, Chee Hau Leow, Eleni Bazigou, Peter D. Weinberg, Meng-Xing Tang

    The very high frame rate afforded by ultrafast ultrasound, combined with microbubble contrast agents, opens new opportunities for imaging tissue microvasculature. However, new imaging paradigms are required to obtain superior image quality from the large amount of acquired data while allowing real-time implementation. In this paper, we report a technique-acoustic subaperture processing (ASAP)-capable of generating very high contrast/signal-to-noise ratio (SNR) images of macroand microvessels, with similar computational complexity to classical power Doppler (PD) imaging. In ASAP, the received data are split into subgroups. The reconstructed data from each subgroup are temporally correlated over frames to generate the final image. As signals in subgroups are correlated but the noise is not, this substantially reduces the noise floor compared to PD. Using a clinical imaging probe, the method is shown to visualize vessels down to 200 μm with a SNR of 10 dB higher than PD and to resolve microvascular flow/perfusion information in rabbit kidneys noninvasively in vivo at multiple centimeter depths. With careful filter design, the technique also allows the estimation of flow direction and the separation of fast flow from tissue perfusion. ASAP can readily be implemented into hardware/firmware for real-time imaging and can be applied to contrast enhanced and potentially noncontrast imaging and 3-D imaging.