Three‐dimensional image integration guidance for cryoballoon pulmonary vein isolation procedures
- 23 October 2019
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 30 (12) , 2790-2796
Abstract
Background: We present a new, easily applicable approach for the guidance of cryoballoon (CB) pulmonary vein isolation (PVI) procedures that use the combination of a 3D‐mapping system image integration module and computed tomographic (CT)–derived anatomy. The aim of this retrospective, nonrandomized study was to investigate: (a) an alternative use for an established radiofrequency image integration module for cryo procedures; (b) a guidance technology for cryo PVI based on integrated CT anatomy; and (c) its clinical impact.Methods and results: CT left atrium–angiography was performed in 50 consecutive patients before a CB PVI procedure, and a 3D reconstruction of the cardiac anatomy was segmented. A total of 25 patients were treated using conventional fluoroscopy; 25 patients were treated using the 3D image integration technique. In the image integration group, the CARTO3 UNIVU (Biosense Webster) module was used for image integration of 3D anatomy and fluoroscopic imaging. Transseptal puncture and cryo PVI were guided by 3D‐overlay imaging. Procedures were feasible without complications in all patients and cryo PVI procedures were successfully guided using the image integration technique. The intraprocedural time needed to perform image integration was 37 ± 10 seconds. Fluoroscopy time was 31.7 ± 11.7 minutes in the conventional group and 20.1 ± 7.9 minutes in the image integration group (P < .001), procedure time was 116.3 ± 29.0 minutes in the conventional group vs 101.2 ± 20.9 minutes in the 3D group (P = .04).Conclusion: 3D‐overlay guidance of CB PVI is feasible, safe, and applicable in real time with minimal effort. It may significantly reduce radiation exposure by introducing 3D information, known from electroanatomic mapping systems, into cryo PVI procedures.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR‐10‐IAHU‐04)
- Deutsche Herzstiftung
This publication has 15 references indexed in Scilit:
- Pulmonary vein measurements on pre-procedural CT/MR imaging can predict difficult pulmonary vein isolation and phrenic nerve injury during cryoballoon ablation for paroxysmal atrial fibrillationInternational Journal of Cardiology, 2015
- Role of High-Resolution Image Integration to Visualize Left Phrenic Nerve and Coronary Arteries During Epicardial Ventricular Tachycardia AblationCirculation: Arrhythmia and Electrophysiology, 2015
- Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmiasEP Europace, 2015
- Accuracy Assessment of Catheter Guidance Technology in Electrophysiology ProceduresJournal of Cardiovascular Electrophysiology, 2013
- Imaging before cryoablation of atrial fibrillation: is phrenic nerve palsy predictable?EP Europace, 2013
- CARTO-guided vs. NavX-guided pulmonary vein antrum isolation and pulmonary vein antrum isolation performed without 3-D mapping: effect of the 3-D mapping system on procedure duration and fluoroscopy timeJournal of Interventional Cardiac Electrophysiology, 2011
- Segmentation and registration of three-dimensional rotational angiogram on live fluoroscopy to guide atrial fibrillation ablation: A new online imaging toolHeart Rhythm, 2009
- Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmiaEP Europace, 2008
- Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX®)EP Europace, 2006
- Cardiac Three-Dimensional Magnetic Resonance Imaging and Fluoroscopy MergingCirculation, 2005