Research on Hand-Transmitted Vibration Prediction Model of the Handheld EVA Power Tool
Open Access
- 14 October 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10373
Abstract
The hand-transmitted vibration generated by extravehicular activity (EVA) power tools has an important impact on the health of astronauts and the efficient completion of maintenance tasks when astronauts use EVA power tools for on-orbit maintenance. Based on the hand-transmitted vibration zero-gravity simulation test platform to measure the vibration response of the EVA power tool to human hands. Given the influence of the length of the operating rod and the number of non-detaching fastening devices on daily vibration exposure when astronauts wear extravehicular spacesuit gloves, a second-order polynomial model and a quadratic cumulative nonlinear model of daily vibration exposure are established. The experimental results show that the second-order polynomial model is more explanatory and predictive of the test data in the scope of the test. The R-values of the palm and opisthenar prediction model are 0.9930 and 0.9940 respectively, and the RMSEs are m/s2 and m/s2. The quadratic cumulative nonlinear model can accurately predict the vibration exposure of the hand outside the scope of the test. This study can provide theoretical reference and data support for the prediction of vibration exposure generated by astronauts using the EVA power tools during on-orbit maintenance.
Keywords
Funding Information
- CAST Science Foundation for Distinguished Young Scholars of China (R-WY-JQRC-19)
This publication has 19 references indexed in Scilit:
- Space Station Solar Array Joint RepairMaterials Performance and Characterization, 2015
- Relationship between simulated extravehicular activity tasks and measurements of physical performanceRespiratory Physiology & Neurobiology, 2014
- Analysis of the effects of surface stiffness on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid modelMedical Engineering & Physics, 2014
- Distributed vibration power absorption of the human hand-arm system in different postures coupled with vibrating handle and power toolsInternational Journal of Industrial Ergonomics, 2013
- Modeling of the biodynamic responses distributed at the fingers and palm of the hand in three orthogonal directionsJournal of Sound and Vibration, 2013
- Methods for deriving a representative biodynamic response of the hand–arm system to vibrationJournal of Sound and Vibration, 2009
- Modeling of biodynamic responses distributed at the fingers and the palm of the human hand–arm systemJournal of Biomechanics, 2007
- Biodynamic Response of Human Fingers in a Power Grip Subjected to a Random VibrationJournal of Biomechanical Engineering, 2004
- Main problems of the Russian Orlan-M space suit utilization for EVAs on the ISS.Acta Astronautica, 2001
- Physiology of a Microgravity Environment Invited Review: Microgravity and skeletal muscleJournal of Applied Physiology, 2000