Abstract
Purpose: Water fraction ( WF ) estimation, a form of quantitative MRI mapping, is typically performed using the variable flip angle ( VFA ) approach. In this study, WF estimation was extended to include the magnetization prepared with 2 rapid gradient echoes ( MP2RAGE ) protocol. The two methods were compared to assess the consistency of WF values across both acquisition strategies. Methods: WF and T 1 maps were calculated using both the VFA and MP2RAGE acquisition protocols. In vivo and phantom datasets were used to assess the comparability of WF estimation between the two methods. Repeatability and reproducibility were evaluated both within each acquisition approach and across the two protocols. Results: High agreement was observed between WF and T 1 maps derived from the VFA and MP2RAGE approaches. The extraction of WF maps from the MP2RAGE protocol was validated, and the consistency of WF estimation across both methods was confirmed. Conclusion: The findings support the use of WF alongside T 1 maps derived from both the VFA and MP2RAGE methods. The ability to obtain reliable WF estimates from either protocol expands the applicability of WF mapping across a broader range of imaging studies.Keywords
Funding Information
- Israel Science Foundation (2449/24)
This publication has 51 references indexed in Scilit:
- Controlled saturation magnetization transfer for reproducible multivendor variable flip angle T1 and T2 mappingMagnetic Resonance in Medicine, 2019
- Evaluating quantitative proton‐density‐mapping methodsHuman Brain Mapping, 2016
- On the accuracy of T1 mapping: Searching for common groundMagnetic Resonance in Medicine, 2014
- Analysis of proton‐density bias corrections based on T1 measurement for robust quantification of water content in the brain at 3 TeslaMagnetic Resonance in Medicine, 2014
- Correction of systematic errors in quantitative proton density mappingMagnetic Resonance in Medicine, 2011
- A robust methodology for in vivo T1 mappingMagnetic Resonance in Medicine, 2010
- Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readoutMagnetic Resonance in Medicine, 2010
- Investigating the effect of exchange and multicomponent T1 relaxation on the short repetition time spoiled steady‐state signal and the DESPOT1 T1 quantification methodJournal of Magnetic Resonance Imaging, 2007
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007
- Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: Relation to estimated iron and water contentsMagnetic Resonance in Medicine, 2001