Echocardiographic findings in patients with cardiac implantable electronic devices-analysis of factors predisposing to lead-associated changes
Authors:
- 1 January 2021
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 41 (1) , 25-41
Abstract
Background The constant interaction between intracardiac leads and the heart and veins results in excessive accumulation of fibrous connective tissue around the leads. The extent of this pathological phenomenon, which is visible on transesophageal echocardiography (TEE), and predisposing factors are not well defined. Methods We examined 936 transesophageal echocardiograms prior to transvenous lead extraction (TLE) performed at a high-volume centre between 2015 and 2019. Results The most important echocardiographic findings were fibrous binding sites between leads and cardiovascular structures, lead-to-lead adhesions, excessive lead loops, lead-dependent tricuspid dysfunction (LDTD), asymptomatic masses on endocardial leads (AMEL) and vegetations. Fibrotic reaction within the walls of the heart and veins correlated with the presence of lead loops (OR = 1.771;p < .01) and lead dwell time (OR = 1.111;p < .001). Women were more likely to have excessive lead loops (OR = 1.639;p < .01), and the occurrence of loops increase with the number of implanted leads (OR = 2.557;p < .001). Heart failure (OR = 4.016;p < .001), lead looping (OR = 2.603;p < .01) and longer cumulative lead dwell time (OR = 1.017;p < .05) increased the likelihood of LDTD. A variety of AMEL were identified in this study, most commonly in patients with older leads (OR = 1.043;p < .001). Conclusions Lead dwell time is the main factor predisposing to the occurrence of most lead-associated phenomena visualized by TEE in patients with cardiac implantable electronic devices (CIED). Excessive looping of the lead is an important cause of fibrous binding sites and LDTD. AMEL are frequently detected in CIED patients, and their various forms concurrent with vegetations could represent an evolutionary stage of lead-associated masses.Keywords
This publication has 37 references indexed in Scilit:
- The Prevalence of Echocardiographic Accretions on the Leads of Patients with Permanent PacemakersJournal of the American Society of Echocardiography, 2011
- Incidence and Significance of Pacemaker and Implantable Cardioverter‐Defibrillator Lead Masses Discovered during Transesophageal EchocardiographyPacing and Clinical Electrophysiology, 2011
- Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade ProceduresCirculation, 2010
- Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodesEP Europace, 2009
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Tricuspid Incompetence Following Permanent Pacemaker ImplantationPacing and Clinical Electrophysiology, 2009
- Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leadsEuropean Heart Journal, 2008
- Clinical Utility of Intraprocedural Transesophageal Echocardiography during Transvenous Lead ExtractionJournal of the American Society of Echocardiography, 2008
- Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leadsJournal of Biomedical Materials Research, 2002
- Effect of the Number of Ventricular Leads on Right Ventricular Hemodynamics in Patients with Permanent PacemakerAngiology, 1995