Hazibullah Waizy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hazibullah Waizy has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Andreas Weizbauer
Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str.1-7, 30625, Hannover, Germany
4 shared publicationsChristina Stukenborg-Colsman
Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str.1-7, 30625, Hannover, Germany
4 shared publicationsHenning Windhagen
Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str.1-7, 30625, Hannover, Germany
4 shared publications- Andrea Meyer-Lindenberg
Clinic for Small Animal Surgery and Reproduction, LMU, Munich, Germany
2 shared publications Berend Denkena
Leibnitz University of Hannover
2 shared publications- Christian Plaass
Orthopädische Klinik der Medizinischen Hochschule Hannover
2 shared publications
Latest Publications
- Open Access
- 23 November 2020
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 19 (1) , 1-2
Correction to: Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study
An amendment to this paper has been published and can be accessed via the original article.
- 23 November 2020
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 19 (1) , 1-2
Open AccessCorrection to: Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study
An amendment to this paper has been published and can be accessed via the original article.
- Top Cited PapersOpen Access
- 3 July 2013
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 62
Biodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study
Purpose: Nondegradable steel-and titanium-based implants are commonly used in orthopedic surgery. Although they provide maximal stability, they are also associated with interference on imaging modalities, may induce stress shielding, and additional explantation procedures may be necessary. Alternatively, degradable polymer implants are mechanically weaker and induce foreign body reactions. Degradable magnesium-based stents are currently being investigated in clinical trials for use in cardiovascular medicine. The magnesium alloy MgYREZr demonstrates good biocompatibility and osteoconductive properties. The aim of this prospective, randomized, clinical pilot trial was to determine if magnesium-based MgYREZr screws are equivalent to standard titanium screws for fixation during chevron osteotomy in patients with a mild hallux valgus.Methods: Patients (n=26) were randomly assigned to undergo osteosynthesis using either titanium or degradable magnesium-based implants of the same design. The 6 month follow-up period included clinical, laboratory, and radiographic assessments.Results: No significant differences were found in terms of the American Orthopaedic Foot and Ankle Society (AOFAS) score for hallux, visual analog scale for pain assessment, or range of motion (ROM) of the first metatarsophalangeal joint (MTPJ). No foreign body reactions, osteolysis, or systemic inflammatory reactions were detected. The groups were not significantly different in terms of radiographic or laboratory results.Conclusion: The radiographic and clinical results of this prospective controlled study demonstrate that degradable magnesium-based screws are equivalent to titanium screws for the treatment of mild hallux valgus deformities.
- 3 July 2013
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 62
Top Cited PapersOpen AccessBiodegradable magnesium-based screw clinically equivalent to titanium screw in hallux valgus surgery: short term results of the first prospective, randomized, controlled clinical pilot study
Purpose: Nondegradable steel-and titanium-based implants are commonly used in orthopedic surgery. Although they provide maximal stability, they are also associated with interference on imaging modalities, may induce stress shielding, and additional explantation procedures may be necessary. Alternatively, degradable polymer implants are mechanically weaker and induce foreign body reactions. Degradable magnesium-based stents are currently being investigated in clinical trials for use in cardiovascular medicine. The magnesium alloy MgYREZr demonstrates good biocompatibility and osteoconductive properties. The aim of this prospective, randomized, clinical pilot trial was to determine if magnesium-based MgYREZr screws are equivalent to standard titanium screws for fixation during chevron osteotomy in patients with a mild hallux valgus.Methods: Patients (n=26) were randomly assigned to undergo osteosynthesis using either titanium or degradable magnesium-based implants of the same design. The 6 month follow-up period included clinical, laboratory, and radiographic assessments.Results: No significant differences were found in terms of the American Orthopaedic Foot and Ankle Society (AOFAS) score for hallux, visual analog scale for pain assessment, or range of motion (ROM) of the first metatarsophalangeal joint (MTPJ). No foreign body reactions, osteolysis, or systemic inflammatory reactions were detected. The groups were not significantly different in terms of radiographic or laboratory results.Conclusion: The radiographic and clinical results of this prospective controlled study demonstrate that degradable magnesium-based screws are equivalent to titanium screws for the treatment of mild hallux valgus deformities.
- 3 January 2013
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 28 (5) , 667-675
In vivo study of a biodegradable orthopedic screw (MgYREZr-alloy) in a rabbit model for up to 12 months
Biodegradable magnesium-based implants are currently being developed for use in orthopedic applications. The aim of this study was to investigate the acute, subacute, and chronic local effects on bone tissue as well as the systemic reactions to a magnesium-based (MgYREZr-alloy) screw containing rare earth elements. The upper part of the screw was implanted into the marrow cavity of the left femora of 15 adult rabbits (New Zealand White), and animals were euthanized 1 week, 12 weeks, and 52 weeks postoperatively. Blood samples were analyzed at set times, and radiographic examinations were performed to evaluate gas formation. There were no significant increased changes in blood values compared to normal levels. Histological examination revealed moderate bone formation with direct implant contact without a fibrous capsule. Histopathological evaluation of lung, liver, intestine, kidneys, pancreas, and spleen tissue samples showed no abnormalities. In summary, our data indicate that these magnesium-based screws containing rare earth elements have good biocompatibility and osteoconductivity without acute, subacute, or chronic toxicity.
- 3 January 2013
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 28 (5) , 667-675
In vivo study of a biodegradable orthopedic screw (MgYREZr-alloy) in a rabbit model for up to 12 months
Biodegradable magnesium-based implants are currently being developed for use in orthopedic applications. The aim of this study was to investigate the acute, subacute, and chronic local effects on bone tissue as well as the systemic reactions to a magnesium-based (MgYREZr-alloy) screw containing rare earth elements. The upper part of the screw was implanted into the marrow cavity of the left femora of 15 adult rabbits (New Zealand White), and animals were euthanized 1 week, 12 weeks, and 52 weeks postoperatively. Blood samples were analyzed at set times, and radiographic examinations were performed to evaluate gas formation. There were no significant increased changes in blood values compared to normal levels. Histological examination revealed moderate bone formation with direct implant contact without a fibrous capsule. Histopathological evaluation of lung, liver, intestine, kidneys, pancreas, and spleen tissue samples showed no abnormalities. In summary, our data indicate that these magnesium-based screws containing rare earth elements have good biocompatibility and osteoconductivity without acute, subacute, or chronic toxicity.
- 1 July 2012
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 10 (2) , 106-113
Bildgebende Diagnostik und Klassifikation chondraler und osteochondraler Läsionen am Talus
- 1 July 2012
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 10 (2) , 106-113
Bildgebende Diagnostik und Klassifikation chondraler und osteochondraler Läsionen am Talus
- 1 July 2012
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 10 (2) , 138-145
Osteochondrale Läsionen des Talus – nicht nur die Oberfläche zählt
- 1 July 2012
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 10 (2) , 138-145
Osteochondrale Läsionen des Talus – nicht nur die Oberfläche zählt
- 24 May 2012
- Published by Springer Nature in Journal of Materials Science
- Vol. 48 (1) , 39-50
Biodegradable magnesium implants for orthopedic applications
- 24 May 2012
- Published by Springer Nature in Journal of Materials Science
- Vol. 48 (1) , 39-50
Biodegradable magnesium implants for orthopedic applications
- Open Access
- 1 January 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 1-14
In vitro corrosion of ZEK100 plates in Hank's Balanced Salt Solution
In recent years magnesium alloys have been intensively investigated as potential resorbable materials with appropriate mechanical and corrosion properties. Particularly in orthopedic research magnesium is interesting because of its mechanical properties close to those of natural bone, the prevention of both stress shielding and removal of the implant after surgery. ZEK100 plates were examined in this in vitro study with Hank's Balanced Salt Solution under physiological conditions with a constant laminar flow rate. After 14, 28 and 42 days of immersion the ZEK100 plates were mechanically tested via four point bending test. The surfaces of the immersed specimens were characterized by SEM, EDX and XRD. The four point bending test displayed an increased bending strength after 6 weeks immersion compared to the 2 week group and 4 week group. The characterization of the surface revealed the presence of high amounts of O, P and Ca on the surface and small Mg content. This indicates the precipitation of calcium phosphates with low solubility on the surface of the ZEK100 plates. The results of the present in vitro study indicate that ZEK100 is a potential candidate for degradable orthopedic implants. Further investigations are needed to examine the degradation behavior.
- 1 January 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 1-14
Open AccessIn vitro corrosion of ZEK100 plates in Hank's Balanced Salt Solution
In recent years magnesium alloys have been intensively investigated as potential resorbable materials with appropriate mechanical and corrosion properties. Particularly in orthopedic research magnesium is interesting because of its mechanical properties close to those of natural bone, the prevention of both stress shielding and removal of the implant after surgery. ZEK100 plates were examined in this in vitro study with Hank's Balanced Salt Solution under physiological conditions with a constant laminar flow rate. After 14, 28 and 42 days of immersion the ZEK100 plates were mechanically tested via four point bending test. The surfaces of the immersed specimens were characterized by SEM, EDX and XRD. The four point bending test displayed an increased bending strength after 6 weeks immersion compared to the 2 week group and 4 week group. The characterization of the surface revealed the presence of high amounts of O, P and Ca on the surface and small Mg content. This indicates the precipitation of calcium phosphates with low solubility on the surface of the ZEK100 plates. The results of the present in vitro study indicate that ZEK100 is a potential candidate for degradable orthopedic implants. Further investigations are needed to examine the degradation behavior.
- 31 December 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 23 (3) , 649-655
Biomechanical characterisation of a degradable magnesium-based (MgCa0.8) screw
Magnesium alloys have been in the focus of research in recent years as degradable biomaterial. The purpose of this study was the biomechanical characterisation of MgCa0.8-screws. The maximum pull out force of screws was determined in a synthetic bone without corrosion and after fixed intervals of corrosion: 24, 48, 72 and 96 h. This in vitro study has been carried out with Hank’s solution with a flow rate corresponding to the blood flow in natural bone. A maximum pull out force (Fmax) of 201.5 ± 9.3 N was measured without corrosion. The biomechanical parameter decreased by 30% after 96 h in corrosive medium compared to the non-corrosion group. A maximum load capacity of 28 ± 7.6 N/h was determined. Our biomechanical data suggests that this biodegradable screw provides a promising bone-screw-fixation and has great potential for medical application.
- 31 December 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 23 (3) , 649-655
Biomechanical characterisation of a degradable magnesium-based (MgCa0.8) screw
Magnesium alloys have been in the focus of research in recent years as degradable biomaterial. The purpose of this study was the biomechanical characterisation of MgCa0.8-screws. The maximum pull out force of screws was determined in a synthetic bone without corrosion and after fixed intervals of corrosion: 24, 48, 72 and 96 h. This in vitro study has been carried out with Hank’s solution with a flow rate corresponding to the blood flow in natural bone. A maximum pull out force (Fmax) of 201.5 ± 9.3 N was measured without corrosion. The biomechanical parameter decreased by 30% after 96 h in corrosive medium compared to the non-corrosion group. A maximum load capacity of 28 ± 7.6 N/h was determined. Our biomechanical data suggests that this biodegradable screw provides a promising bone-screw-fixation and has great potential for medical application.
- 1 December 2011
- Vol. 149 (6) , 621
[Angulation of the ankle joint--the fibula must be considered!].
- Open Access
- 1 December 2011
- Published by Springer Nature in Respiratory Research
- Vol. 12 (1) , 79
Ultrastructural changes of the intracellular surfactant pool in a rat model of lung transplantation-related events
Ischemia/reperfusion (I/R) injury, involved in primary graft dysfunction following lung transplantation, leads to inactivation of intra-alveolar surfactant which facilitates injury of the blood-air barrier. The alveolar epithelial type II cells (AE2 cells) synthesize, store and secrete surfactant; thus, an intracellular surfactant pool stored in lamellar bodies (Lb) can be distinguished from the intra-alveolar surfactant pool. The aim of this study was to investigate ultrastructural alterations of the intracellular surfactant pool in a model, mimicking transplantation-related procedures including flush perfusion, cold ischemia and reperfusion combined with mechanical ventilation.
- 1 December 2011
- Published by Springer Nature in Respiratory Research
- Vol. 12 (1) , 79
Open AccessUltrastructural changes of the intracellular surfactant pool in a rat model of lung transplantation-related events
Ischemia/reperfusion (I/R) injury, involved in primary graft dysfunction following lung transplantation, leads to inactivation of intra-alveolar surfactant which facilitates injury of the blood-air barrier. The alveolar epithelial type II cells (AE2 cells) synthesize, store and secrete surfactant; thus, an intracellular surfactant pool stored in lamellar bodies (Lb) can be distinguished from the intra-alveolar surfactant pool. The aim of this study was to investigate ultrastructural alterations of the intracellular surfactant pool in a model, mimicking transplantation-related procedures including flush perfusion, cold ischemia and reperfusion combined with mechanical ventilation.