Peter P. Antich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter P. Antich has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Edmond Richer
Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, USA
5 shared publications - Matthew A. Lewis
The University of Texas Southwestern Medical Center, Department of Radiology, Dallas, Texas, United States
4 shared publications - Ralph Peter Mason
Department of Radiology, The University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390-9058, United States
4 shared publications Matthew Lewis
2 shared publications- Nikolai V. Slavine
Research Division, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas, 75390-9071, USA
2 shared publications Peiying Liu
Dept. of Radiol., UT Southwestern Medical Ctr. at Dallas, 5323 Harry Hines Blvd., Dallas, TX 75390-9058
2 shared publications
Latest Publications
- Open Access
- 9 July 2013
- Published by MDPI AG in Diagnostics
- Vol. 3 (3) , 325-343
A Multi-Camera System for Bioluminescence Tomography in Preclinical Oncology Research
Bioluminescent imaging (BLI) of cells expressing luciferase is a valuable noninvasive technique for investigating molecular events and tumor dynamics in the living animal. Current usage is often limited to planar imaging, but tomographic imaging can enhance the usefulness of this technique in quantitative biomedical studies by allowing accurate determination of tumor size and attribution of the emitted light to a specific organ or tissue. Bioluminescence tomography based on a single camera with source rotation or mirrors to provide additional views has previously been reported. We report here in vivo studies using a novel approach with multiple rotating cameras that, when combined with image reconstruction software, provides the desired representation of point source metastases and other small lesions. Comparison with MRI validated the ability to detect lung tumor colonization in mouse lung.
- 9 July 2013
- Published by MDPI AG in Diagnostics
- Vol. 3 (3) , 325-343
Open AccessA Multi-Camera System for Bioluminescence Tomography in Preclinical Oncology Research
Bioluminescent imaging (BLI) of cells expressing luciferase is a valuable noninvasive technique for investigating molecular events and tumor dynamics in the living animal. Current usage is often limited to planar imaging, but tomographic imaging can enhance the usefulness of this technique in quantitative biomedical studies by allowing accurate determination of tumor size and attribution of the emitted light to a specific organ or tissue. Bioluminescence tomography based on a single camera with source rotation or mirrors to provide additional views has previously been reported. We report here in vivo studies using a novel approach with multiple rotating cameras that, when combined with image reconstruction software, provides the desired representation of point source metastases and other small lesions. Comparison with MRI validated the ability to detect lung tumor colonization in mouse lung.
- 15 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 54 (5) , 1516-1524
Development and Evaluation of an EMCCD Based Gamma Camera for Preclinical SPECT Imaging
The electron-multiplying charge-coupled device (EMCCD) offers improved quantum efficiencies (40 to 95%) over a broader range of wavelengths (400 to 900 nm) and a higher intrinsic resolution (<100 mum using photon counting) when compared to photomultiplier tubes. The electron gain achieved in the multiplication register of an EMCCD effectively reduces the readout noise to less than 1 electron/pixel, making them sensitive to single photoelectrons. Our prototype camera uses the Texas Instruments Impactrontrade EMCCD model TC253SPD-B0 (7.4 mum square pixels) which is cooled under vacuum to -50degC using a four stage Peltier and liquid heat exchanger. Shuttered lens-coupling is used to image the optical light from a 3 mm thick monolithic CsI(Tl) crystal. Precise clocking for the EMCCD is provided by a National Instruments FPGA controller (PCI-7811R) and LabVIEW FPGA module (version 8.0). A custom built electronics box contains the clock driver circuitry and 16-bit video board for digital conversion of the video signal. Our optical coupling method differs from other EMCCD SPECT systems by using lenses rather than fiber optic bundles for transfer. TC253 characterization tests measured a maximum gain just over 1000times, dark current rate of 0.14 e/p/s, read noise of 18.2 e/p, and spurious charge generation of 4 e/p. A light integration intrinsic resolution of 110 mum FWHM was measured. Light integration images of a line phantom using a single pinhole collimator were used for SPECT reconstruction. We found the relative high spurious charge generation and low quantum efficiency of the TC253 made it incapable of photon counting for low energy sources using lens coupling.
- 15 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 54 (5) , 1516-1524
Development and Evaluation of an EMCCD Based Gamma Camera for Preclinical SPECT Imaging
The electron-multiplying charge-coupled device (EMCCD) offers improved quantum efficiencies (40 to 95%) over a broader range of wavelengths (400 to 900 nm) and a higher intrinsic resolution (<100 mum using photon counting) when compared to photomultiplier tubes. The electron gain achieved in the multiplication register of an EMCCD effectively reduces the readout noise to less than 1 electron/pixel, making them sensitive to single photoelectrons. Our prototype camera uses the Texas Instruments Impactrontrade EMCCD model TC253SPD-B0 (7.4 mum square pixels) which is cooled under vacuum to -50degC using a four stage Peltier and liquid heat exchanger. Shuttered lens-coupling is used to image the optical light from a 3 mm thick monolithic CsI(Tl) crystal. Precise clocking for the EMCCD is provided by a National Instruments FPGA controller (PCI-7811R) and LabVIEW FPGA module (version 8.0). A custom built electronics box contains the clock driver circuitry and 16-bit video board for digital conversion of the video signal. Our optical coupling method differs from other EMCCD SPECT systems by using lenses rather than fiber optic bundles for transfer. TC253 characterization tests measured a maximum gain just over 1000times, dark current rate of 0.14 e/p/s, read noise of 18.2 e/p, and spurious charge generation of 4 e/p. A light integration intrinsic resolution of 110 mum FWHM was measured. Light integration images of a line phantom using a single pinhole collimator were used for SPECT reconstruction. We found the relative high spurious charge generation and low quantum efficiency of the TC253 made it incapable of photon counting for low energy sources using lens coupling.
- 1 November 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (5_Suppleme) , 3243-3244
Direct evaluation of cancellous bone porosity using ultrasound
- 1 November 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (5_Suppleme) , 3243-3244
Direct evaluation of cancellous bone porosity using ultrasound
- 1 November 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (5_Suppleme) , 3025
Linear sampling method for acoustic inverse scattering in breast microcalcification detection
- 1 November 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (5_Suppleme) , 3025
Linear sampling method for acoustic inverse scattering in breast microcalcification detection
- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2491-2492
Ultrasound critical angle-reflectometry: Measuring ultrasound velocities in the clinic and in the laboratory
- 1 October 2004
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 116 (4_Suppleme) , 2491-2492
Ultrasound critical angle-reflectometry: Measuring ultrasound velocities in the clinic and in the laboratory
- 25 August 2003
- Published by Wiley in Journal of Cellular Biochemistry
- Vol. 90 (3) , 473-483
Molecular imaging in prostate cancer
Prostate cancer (PCa) is the most common non‐cutaneous malignancy in men. New ways to diagnose this cancer in its early stages are needed. Unique genetic and biochemical changes in the cell pave the way for tumors to grow and metastasize. Novel imaging approaches attempt to detect pathological processes in cancer cells at the molecular level. This has led to the establishment and development of the field of molecular imaging. Positron emission tomography (PET), magnetic resonance spectroscopic imaging (MRSI), magnetic resonance imaging (MRI), and radiolabeled antibodies are a few of the modalities that can detect abnormal tumor metabolic processes in the clinical setting. Other imaging techniques are still in their early phase of development but hold promise for the future, including bioluminescence imaging (BLI), measurement of tumor oxygenation, and measurement of uptake of iodine by tumors. These techniques are non‐invasive and can spare the patient undue morbidity, while potentially providing early diagnosis, accurate follow‐up and, finally, valuable prognostic information.
- 25 August 2003
- Published by Wiley in Journal of Cellular Biochemistry
- Vol. 90 (3) , 473-483
Molecular imaging in prostate cancer
Prostate cancer (PCa) is the most common non‐cutaneous malignancy in men. New ways to diagnose this cancer in its early stages are needed. Unique genetic and biochemical changes in the cell pave the way for tumors to grow and metastasize. Novel imaging approaches attempt to detect pathological processes in cancer cells at the molecular level. This has led to the establishment and development of the field of molecular imaging. Positron emission tomography (PET), magnetic resonance spectroscopic imaging (MRSI), magnetic resonance imaging (MRI), and radiolabeled antibodies are a few of the modalities that can detect abnormal tumor metabolic processes in the clinical setting. Other imaging techniques are still in their early phase of development but hold promise for the future, including bioluminescence imaging (BLI), measurement of tumor oxygenation, and measurement of uptake of iodine by tumors. These techniques are non‐invasive and can spare the patient undue morbidity, while potentially providing early diagnosis, accurate follow‐up and, finally, valuable prognostic information.
- 1 May 1996
- Published by Wiley in NMR in Biomedicine
- Vol. 9 (3) , 125-134
Hexafluorobenzene: a Sensitive 19F NMR Indicator of Tumor Oxygenation
- 1 May 1996
- Published by Wiley in NMR in Biomedicine
- Vol. 9 (3) , 125-134
Hexafluorobenzene: a Sensitive 19F NMR Indicator of Tumor Oxygenation