Edmond Richer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Edmond Richer has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Peter P. Antich
Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX 75390, USA
5 shared publications - Matthew A. Lewis
The University of Texas Southwestern Medical Center, Department of Radiology, Dallas, Texas, United States
4 shared publications - Ralph Peter Mason
Department of Radiology, The University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390-9058, United States
3 shared publications Bryan Cox
Department of Mechanical Engineering, Southern Methodist University, Dallas, Texas
2 shared publicationsMatt Saari
Department of Mechanical Engineering, Southern Methodist University, Dallas, Texas
2 shared publications- Nikolai V. Slavine
Research Division, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas, 75390-9071, USA
2 shared publications
Latest Publications
- 14 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (3) , 2196-2207
Design and Static Equilibrium Analysis of a Modular Pipe Inspection Robot
Inspection of tube networks is an important process in the manufacturing and maintenance of aircraft. Currently, borescopes are commonly used with limited success. To improve the inspection process, a prototype design based on a vertebra concept is introduced, analyzed, and optimized. The modular robotic inspection system (MoRIS) allows for a microsized camera to be driven noninvasively through a 3-m-long, 36-mm internal diameter tube network. MoRIS provides a complete view of the tube walls. Our system includes a localization algorithm that tracks the progress of the robot inside the tubes. This algorithm results in an experimentally validated error of 19.7 mm. Using MoRIS, operators can inspect tube networks that previously required hazardous disassembly of aircraft.
- 14 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (3) , 2196-2207
Design and Static Equilibrium Analysis of a Modular Pipe Inspection Robot
Inspection of tube networks is an important process in the manufacturing and maintenance of aircraft. Currently, borescopes are commonly used with limited success. To improve the inspection process, a prototype design based on a vertebra concept is introduced, analyzed, and optimized. The modular robotic inspection system (MoRIS) allows for a microsized camera to be driven noninvasively through a 3-m-long, 36-mm internal diameter tube network. MoRIS provides a complete view of the tube walls. Our system includes a localization algorithm that tracks the progress of the robot inside the tubes. This algorithm results in an experimentally validated error of 19.7 mm. Using MoRIS, operators can inspect tube networks that previously required hazardous disassembly of aircraft.
- 20 July 2021
- Published by Wiley
- p. 33-63
The Kinematics of Explosively Jerky Diatom Motility: A Natural Example of Active Nanofluidics
- 20 July 2021
- Published by Wiley
- p. 33-63
The Kinematics of Explosively Jerky Diatom Motility: A Natural Example of Active Nanofluidics
- 3 March 2020
- Published by ASME International in ASME Letters in Dynamic Systems and Control
- Vol. 1 (1) , 1-6
Lumped Parameter Modeling and Snap-Through Stability Analysis of Planar Hydraulically Amplified Dielectric Elastomer Actuators
In this paper, we established an analytical model that avoids extensive numerical computation for the analysis of a hydraulically amplified dielectric elastomer actuator. This actuator comprises a thin elastomer shell filled with an incompressible dielectric fluid coupled with a pair of electrodes placed in the central area. Application of high voltage on the electrodes inflates the actuator due to the induced Maxwell stress that pressurizes the incompressible dielectric fluid. The lumped parameter model predicts the stable functional region and the snap-through instability in the actuator. The model was compared with multi-physics finite element models that considered both linear elastic and nonlinear Mooney–Rivlin materials. The proposed model showed good agreement in the estimation of the actuation strain and the hydrostatic pressure as a function of voltage when compared to the finite element results. The average error in the axial and radial actuation using the proposed analytical model and nonlinear finite element method models was 1.62% and 3.42%, respectively. This shows the model strength in the estimation of the actuator states and the critical voltage to avoid snap-through instability, required in applications such as control algorithms.
- 3 March 2020
- Published by ASME International in ASME Letters in Dynamic Systems and Control
- Vol. 1 (1) , 1-6
Lumped Parameter Modeling and Snap-Through Stability Analysis of Planar Hydraulically Amplified Dielectric Elastomer Actuators
In this paper, we established an analytical model that avoids extensive numerical computation for the analysis of a hydraulically amplified dielectric elastomer actuator. This actuator comprises a thin elastomer shell filled with an incompressible dielectric fluid coupled with a pair of electrodes placed in the central area. Application of high voltage on the electrodes inflates the actuator due to the induced Maxwell stress that pressurizes the incompressible dielectric fluid. The lumped parameter model predicts the stable functional region and the snap-through instability in the actuator. The model was compared with multi-physics finite element models that considered both linear elastic and nonlinear Mooney–Rivlin materials. The proposed model showed good agreement in the estimation of the actuation strain and the hydrostatic pressure as a function of voltage when compared to the finite element results. The average error in the axial and radial actuation using the proposed analytical model and nonlinear finite element method models was 1.62% and 3.42%, respectively. This shows the model strength in the estimation of the actuator states and the critical voltage to avoid snap-through instability, required in applications such as control algorithms.
- 1 November 2019
- Published by Elsevier in Mechatronics
- Vol. 63
Adaptive notch filter for pathological tremor suppression using permanent magnet linear motor
- 1 November 2019
- Published by Elsevier in Mechatronics
- Vol. 63
Adaptive notch filter for pathological tremor suppression using permanent magnet linear motor
- 1 September 2016
- Published by SAGE Publications in 3D Printing and Additive Manufacturing
- Vol. 3 (3) , 136-141
Fabrication and Analysis of a Composite 3D Printed Capacitive Force Sensor
Fiber encapsulation additive manufacturing (FEAM) and thermoplastic elastomer additive manufacturing (TEAM) are combined to create a composite capacitive force sensor. This work presents analysis on a capacitive force sensor developed by combining the advantages of FEAM and TEAM. The capacitive sensor consists of a 3D printed rigid frame with embedded wires in a tight spiral pattern that emulates a flat plate capacitor and a thermoplastic elastomer dielectric spacer that compresses under applied force. An approximately linear response for the corresponding capacitance change versus applied load is obtained to evaluate the printed capacitor effectiveness as a force sensor.
- 1 September 2016
- Published by SAGE Publications in 3D Printing and Additive Manufacturing
- Vol. 3 (3) , 136-141
Fabrication and Analysis of a Composite 3D Printed Capacitive Force Sensor
Fiber encapsulation additive manufacturing (FEAM) and thermoplastic elastomer additive manufacturing (TEAM) are combined to create a composite capacitive force sensor. This work presents analysis on a capacitive force sensor developed by combining the advantages of FEAM and TEAM. The capacitive sensor consists of a 3D printed rigid frame with embedded wires in a tight spiral pattern that emulates a flat plate capacitor and a thermoplastic elastomer dielectric spacer that compresses under applied force. An approximately linear response for the corresponding capacitance change versus applied load is obtained to evaluate the printed capacitor effectiveness as a force sensor.
- Open Access
- 9 July 2013
- Published by MDPI AG in Diagnostics
- Vol. 3 (3) , 325-343
A Multi-Camera System for Bioluminescence Tomography in Preclinical Oncology Research
Bioluminescent imaging (BLI) of cells expressing luciferase is a valuable noninvasive technique for investigating molecular events and tumor dynamics in the living animal. Current usage is often limited to planar imaging, but tomographic imaging can enhance the usefulness of this technique in quantitative biomedical studies by allowing accurate determination of tumor size and attribution of the emitted light to a specific organ or tissue. Bioluminescence tomography based on a single camera with source rotation or mirrors to provide additional views has previously been reported. We report here in vivo studies using a novel approach with multiple rotating cameras that, when combined with image reconstruction software, provides the desired representation of point source metastases and other small lesions. Comparison with MRI validated the ability to detect lung tumor colonization in mouse lung.
- 9 July 2013
- Published by MDPI AG in Diagnostics
- Vol. 3 (3) , 325-343
Open AccessA Multi-Camera System for Bioluminescence Tomography in Preclinical Oncology Research
Bioluminescent imaging (BLI) of cells expressing luciferase is a valuable noninvasive technique for investigating molecular events and tumor dynamics in the living animal. Current usage is often limited to planar imaging, but tomographic imaging can enhance the usefulness of this technique in quantitative biomedical studies by allowing accurate determination of tumor size and attribution of the emitted light to a specific organ or tissue. Bioluminescence tomography based on a single camera with source rotation or mirrors to provide additional views has previously been reported. We report here in vivo studies using a novel approach with multiple rotating cameras that, when combined with image reconstruction software, provides the desired representation of point source metastases and other small lesions. Comparison with MRI validated the ability to detect lung tumor colonization in mouse lung.
- 1 January 2011
- Published by ASME International
- p. 595-600
Robust Tremor Attenuation for Single DOF Model of Human Elbow Joint With Parametric Uncertainties
In this article, a tremor attenuation algorithm is designed based on the backstepping method. A high-pass filter was designed in frequency domain and its state space realization was derived to be used as an estimator for the tremorous motion. Using the pole placement method an appropriate state feedback control law was designed to stabilize its output. The dynamics of the human arm was considered and a backstepping controller was derived for the applied torque to the arm. The global asymptotic stability of the resulting closed-loop system was proved using Lyapunov method. The controller is robust against parametric uncertainty and unmodeled nonlinear terms of the arm dynamical model. Simulation results shows the successful suppression of tremor in the presence of parametric uncertainty.
- 1 January 2011
- Published by ASME International
- p. 595-600
Robust Tremor Attenuation for Single DOF Model of Human Elbow Joint With Parametric Uncertainties
In this article, a tremor attenuation algorithm is designed based on the backstepping method. A high-pass filter was designed in frequency domain and its state space realization was derived to be used as an estimator for the tremorous motion. Using the pole placement method an appropriate state feedback control law was designed to stabilize its output. The dynamics of the human arm was considered and a backstepping controller was derived for the applied torque to the arm. The global asymptotic stability of the resulting closed-loop system was proved using Lyapunov method. The controller is robust against parametric uncertainty and unmodeled nonlinear terms of the arm dynamical model. Simulation results shows the successful suppression of tremor in the presence of parametric uncertainty.
- Open Access
- 13 July 2009
- Published by Springer Nature
- Vol. 574, 37-45
High-Throughput Quantitative Bioluminescence Imaging for Assessing Tumor Burden
Bioluminescence imaging (BLI) has emerged during the past 5 years as the preeminent method for rapid, cheap, facile screening of tumor growth and spread in mice. Both subcutaneous and orthotopic tumor models are readily observed with high sensitivity and reproducibility. User-friendly commercial instruments exist and, increasingly, luciferase-expressing tumor cells are available in academic institutions or commercially. There is an increasing literature on routine use of BLI for assessing chemotherapeutic efficacy, drug combinations, dosing, and timing. In addition, BLI may be applied to more sophisticated questions of molecular biology by including specific promoter sequences. This chapter will describe routine methods used to support multiple investigators in our small animal imaging resource.
- 13 July 2009
- Published by Springer Nature
- Vol. 574, 37-45
Open AccessHigh-Throughput Quantitative Bioluminescence Imaging for Assessing Tumor Burden
Bioluminescence imaging (BLI) has emerged during the past 5 years as the preeminent method for rapid, cheap, facile screening of tumor growth and spread in mice. Both subcutaneous and orthotopic tumor models are readily observed with high sensitivity and reproducibility. User-friendly commercial instruments exist and, increasingly, luciferase-expressing tumor cells are available in academic institutions or commercially. There is an increasing literature on routine use of BLI for assessing chemotherapeutic efficacy, drug combinations, dosing, and timing. In addition, BLI may be applied to more sophisticated questions of molecular biology by including specific promoter sequences. This chapter will describe routine methods used to support multiple investigators in our small animal imaging resource.
- 15 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 54 (5) , 1516-1524
Development and Evaluation of an EMCCD Based Gamma Camera for Preclinical SPECT Imaging
The electron-multiplying charge-coupled device (EMCCD) offers improved quantum efficiencies (40 to 95%) over a broader range of wavelengths (400 to 900 nm) and a higher intrinsic resolution (<100 mum using photon counting) when compared to photomultiplier tubes. The electron gain achieved in the multiplication register of an EMCCD effectively reduces the readout noise to less than 1 electron/pixel, making them sensitive to single photoelectrons. Our prototype camera uses the Texas Instruments Impactrontrade EMCCD model TC253SPD-B0 (7.4 mum square pixels) which is cooled under vacuum to -50degC using a four stage Peltier and liquid heat exchanger. Shuttered lens-coupling is used to image the optical light from a 3 mm thick monolithic CsI(Tl) crystal. Precise clocking for the EMCCD is provided by a National Instruments FPGA controller (PCI-7811R) and LabVIEW FPGA module (version 8.0). A custom built electronics box contains the clock driver circuitry and 16-bit video board for digital conversion of the video signal. Our optical coupling method differs from other EMCCD SPECT systems by using lenses rather than fiber optic bundles for transfer. TC253 characterization tests measured a maximum gain just over 1000times, dark current rate of 0.14 e/p/s, read noise of 18.2 e/p, and spurious charge generation of 4 e/p. A light integration intrinsic resolution of 110 mum FWHM was measured. Light integration images of a line phantom using a single pinhole collimator were used for SPECT reconstruction. We found the relative high spurious charge generation and low quantum efficiency of the TC253 made it incapable of photon counting for low energy sources using lens coupling.
- 15 October 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 54 (5) , 1516-1524
Development and Evaluation of an EMCCD Based Gamma Camera for Preclinical SPECT Imaging
The electron-multiplying charge-coupled device (EMCCD) offers improved quantum efficiencies (40 to 95%) over a broader range of wavelengths (400 to 900 nm) and a higher intrinsic resolution (<100 mum using photon counting) when compared to photomultiplier tubes. The electron gain achieved in the multiplication register of an EMCCD effectively reduces the readout noise to less than 1 electron/pixel, making them sensitive to single photoelectrons. Our prototype camera uses the Texas Instruments Impactrontrade EMCCD model TC253SPD-B0 (7.4 mum square pixels) which is cooled under vacuum to -50degC using a four stage Peltier and liquid heat exchanger. Shuttered lens-coupling is used to image the optical light from a 3 mm thick monolithic CsI(Tl) crystal. Precise clocking for the EMCCD is provided by a National Instruments FPGA controller (PCI-7811R) and LabVIEW FPGA module (version 8.0). A custom built electronics box contains the clock driver circuitry and 16-bit video board for digital conversion of the video signal. Our optical coupling method differs from other EMCCD SPECT systems by using lenses rather than fiber optic bundles for transfer. TC253 characterization tests measured a maximum gain just over 1000times, dark current rate of 0.14 e/p/s, read noise of 18.2 e/p, and spurious charge generation of 4 e/p. A light integration intrinsic resolution of 110 mum FWHM was measured. Light integration images of a line phantom using a single pinhole collimator were used for SPECT reconstruction. We found the relative high spurious charge generation and low quantum efficiency of the TC253 made it incapable of photon counting for low energy sources using lens coupling.