Aiming Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aiming Lu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Keith R. Thulborn
Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, IL 60612, United States
4 shared publications Ian C. Atkinson
Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
3 shared publicationsBruce L. Daniel
Department of Radiology, Stanford University, Stanford, California, USA
2 shared publicationsKim Butts Pauly
Department of Radiology, Stanford University, Stanford, California, USA
2 shared publicationsElena Kaye
Department of Radiology, Stanford University, Stanford, California, USA
1 shared publicationFrederick C. Damen
Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA
1 shared publication
Latest Publications
- Open Access
- 23 April 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (2) , 538-544
PCr/ATP ratio mapping of the human head by simultaneously imaging of multiple spectral peaks with interleaved excitations and flexible twisted projection imaging readout trajectories at 9.4 T
Quantitative 31P magnetic resonance imaging of the whole human brain is often time‐consuming even at low spatial resolution due to the low concentrations, long T1 relaxation times, and low detection sensitivity of phosphorus metabolites. We report herein the results of combining the increased detection sensitivity of an ultra‐high field 9.4 T scanner designed for human imaging with a new pulse sequence termed simultaneously imaging of multiple spectral peaks with interleaved excitations and flexible twisted projection imaging readout trajectories to rapidly sample multiple resonances in the 31P spectrum. The phosphocreatine and γ‐adenosine triphosphate images, obtained simultaneously from the entire human head, are demonstrated at 1.5 cm isotropic nominal resolution in a total acquisition time of 33 min. The phosphocreatine/γ‐adenosine triphosphate ratio calculated for brain parenchyma ( 1, 2 ) and the superficial temporalis muscle ( 3-5 ) are in agreement with literature values. Magn Reson Med, 2013.
- 23 April 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (2) , 538-544
Open AccessPCr/ATP ratio mapping of the human head by simultaneously imaging of multiple spectral peaks with interleaved excitations and flexible twisted projection imaging readout trajectories at 9.4 T
Quantitative 31P magnetic resonance imaging of the whole human brain is often time‐consuming even at low spatial resolution due to the low concentrations, long T1 relaxation times, and low detection sensitivity of phosphorus metabolites. We report herein the results of combining the increased detection sensitivity of an ultra‐high field 9.4 T scanner designed for human imaging with a new pulse sequence termed simultaneously imaging of multiple spectral peaks with interleaved excitations and flexible twisted projection imaging readout trajectories to rapidly sample multiple resonances in the 31P spectrum. The phosphocreatine and γ‐adenosine triphosphate images, obtained simultaneously from the entire human head, are demonstrated at 1.5 cm isotropic nominal resolution in a total acquisition time of 33 min. The phosphocreatine/γ‐adenosine triphosphate ratio calculated for brain parenchyma ( 1, 2 ) and the superficial temporalis muscle ( 3-5 ) are in agreement with literature values. Magn Reson Med, 2013.
- 31 December 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 213 (1) , 176-181
Impact of gradient timing error on the tissue sodium concentration bioscale measured using flexible twisted projection imaging
- 31 December 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 213 (1) , 176-181
Impact of gradient timing error on the tissue sodium concentration bioscale measured using flexible twisted projection imaging
- 21 June 2011
- Published by Springer Nature
- p. 911-928
Metabolic Magnetic Resonance Imaging: A Case for Bioscales in Medicine
- 21 June 2011
- Published by Springer Nature
- p. 911-928
Metabolic Magnetic Resonance Imaging: A Case for Bioscales in Medicine
- Open Access
- 31 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (6) , 1582-1589
MRI of frozen tissue demonstrates a phase shift
While temperature mapping is desired during cryosurgery for prostate cancer treatment, an effective approach for this purpose is still needed. We have demonstrated a phase shift with temperature in our in vivo canine experiments and ex vivo tissue sample experiments within the frozen tissue. The phase shift is much larger (∼0.7 °/°C with an echo time of 0.1 ms at 0.5 T) in magnitude than that predicted by conventional proton resonant frequency shift (0.008 °/°C). It shows little dependence on the echo times used and thus is not due to a frequency change, although frequency‐dependent phase shift has been observed near the frozen tissue. This phase shift varies monotonically with temperature within the frozen tissue and therefore may be potentially used as a novel temperature mapping approach in cryoablation applications. Magn Reson Med, 2011.
- 31 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (6) , 1582-1589
Open AccessMRI of frozen tissue demonstrates a phase shift
While temperature mapping is desired during cryosurgery for prostate cancer treatment, an effective approach for this purpose is still needed. We have demonstrated a phase shift with temperature in our in vivo canine experiments and ex vivo tissue sample experiments within the frozen tissue. The phase shift is much larger (∼0.7 °/°C with an echo time of 0.1 ms at 0.5 T) in magnitude than that predicted by conventional proton resonant frequency shift (0.008 °/°C). It shows little dependence on the echo times used and thus is not due to a frequency change, although frequency‐dependent phase shift has been observed near the frozen tissue. This phase shift varies monotonically with temperature within the frozen tissue and therefore may be potentially used as a novel temperature mapping approach in cryoablation applications. Magn Reson Med, 2011.
- Open Access
- 21 May 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (6) , 1583-1593
Quantitative sodium imaging with a flexible twisted projection pulse sequence
The quantification of sodium MR images from an arbitrary intensity scale into a bioscale fosters image interpretation in terms of the spatially resolved biochemical process of sodium ion homeostasis. A methodology for quantifying tissue sodium concentration using a flexible twisted projection imaging sequence is proposed that allows for optimization of tradeoffs between readout time, signal‐to‐noise ratio efficiency, and sensitivity to static field susceptibility artifacts. The gradient amplitude supported by the slew rate at each k‐space radius regularizes the readout gradient waveform design to avoid slew rate violation. Static field inhomogeneity artifacts are corrected using a frequency‐segmented conjugate phase reconstruction approach, with field maps obtained quickly from coregistered proton imaging. High‐quality quantitative sodium images have been achieved in phantom and volunteer studies with real isotropic spatial resolution of 7.5 × 7.5 × 7.5 mm3 for the slow T2 component in ∼8 min on a clinical 3‐T scanner. After correcting for coil sensitivity inhomogeneity and water fraction, the tissue sodium concentration in gray matter and white matter was measured to be 36.6 ± 0.6 μmol/g wet weight and 27.6 ± 1.2 μmol/g wet weight, respectively. Magn Reson Med 63:1583–1593, 2010.
- 21 May 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (6) , 1583-1593
Open AccessQuantitative sodium imaging with a flexible twisted projection pulse sequence
The quantification of sodium MR images from an arbitrary intensity scale into a bioscale fosters image interpretation in terms of the spatially resolved biochemical process of sodium ion homeostasis. A methodology for quantifying tissue sodium concentration using a flexible twisted projection imaging sequence is proposed that allows for optimization of tradeoffs between readout time, signal‐to‐noise ratio efficiency, and sensitivity to static field susceptibility artifacts. The gradient amplitude supported by the slew rate at each k‐space radius regularizes the readout gradient waveform design to avoid slew rate violation. Static field inhomogeneity artifacts are corrected using a frequency‐segmented conjugate phase reconstruction approach, with field maps obtained quickly from coregistered proton imaging. High‐quality quantitative sodium images have been achieved in phantom and volunteer studies with real isotropic spatial resolution of 7.5 × 7.5 × 7.5 mm3 for the slow T2 component in ∼8 min on a clinical 3‐T scanner. After correcting for coil sensitivity inhomogeneity and water fraction, the tissue sodium concentration in gray matter and white matter was measured to be 36.6 ± 0.6 μmol/g wet weight and 27.6 ± 1.2 μmol/g wet weight, respectively. Magn Reson Med 63:1583–1593, 2010.
- Open Access
- 25 June 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (1) , 190-198
Improved slice selection for R2* mapping during cryoablation with eddy current compensation
Purpose To improve the slice profile and image quality of R2* mapping in the iceball during cryoablation with ultrashort echo time (UTE) imaging by compensating for eddy currents induced by the selective gradient when half‐pulse radiofrequency (RF) excitation is employed to achieve UTEs. Materials and Methods A method to measure both B0 and linear eddy currents simultaneously is first presented. This is done with a least‐square fitting process on calibration data collected on a phantom. Eddy currents during excitation are compensated by redesigning the RF pulse and the selective gradient accordingly, while that resultant from the readout gradient are compensated for during image reconstruction. In vivo data were obtained continuously during the cryoablation experiments to calculate the R2* values in the iceball and to correlate them with the freezing process. Results Image quality degradation due to eddy currents is significantly reduced with the proposed approaches. R2* maps of iceball throughout the cryoablation experiments were achieved with improved quality. Conclusion The proposed approaches are effective for compensating eddy currents during half‐pulse RF excitation as well as readout. TEs as short as 100 μsec were obtained, allowing R2* maps to be obtained from frozen tissues with improved quality. J. Magn. Reson. Imaging 2008;28:190–198.
- 25 June 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (1) , 190-198
Open AccessImproved slice selection for R2* mapping during cryoablation with eddy current compensation
Purpose To improve the slice profile and image quality of R2* mapping in the iceball during cryoablation with ultrashort echo time (UTE) imaging by compensating for eddy currents induced by the selective gradient when half‐pulse radiofrequency (RF) excitation is employed to achieve UTEs. Materials and Methods A method to measure both B0 and linear eddy currents simultaneously is first presented. This is done with a least‐square fitting process on calibration data collected on a phantom. Eddy currents during excitation are compensated by redesigning the RF pulse and the selective gradient accordingly, while that resultant from the readout gradient are compensated for during image reconstruction. In vivo data were obtained continuously during the cryoablation experiments to calculate the R2* values in the iceball and to correlate them with the freezing process. Results Image quality degradation due to eddy currents is significantly reduced with the proposed approaches. R2* maps of iceball throughout the cryoablation experiments were achieved with improved quality. Conclusion The proposed approaches are effective for compensating eddy currents during half‐pulse RF excitation as well as readout. TEs as short as 100 μsec were obtained, allowing R2* maps to be obtained from frozen tissues with improved quality. J. Magn. Reson. Imaging 2008;28:190–198.