YDYiping P. Du

Yiping P. Du

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yiping P. Du has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reduction of artifacts in susceptibility‐weighted MR venography of the brain

    by Zhaoyang Jin, Ling Xia, Yiping P. Du

    Purpose: To reduce the off‐resonance artifact in susceptibility‐weighted imaging (SWI)‐based MR venography (MRV) in the brain regions with severe field inhomogeneity and to reduce the signal loss in the minimum‐intensity projection (mIP) display of the 3D MRV.Materials and Methods: A novel postprocessing approach was presented to map the local field gradients (LFGs) using the 3D SWI data without phase‐unwrapping. LFG measurements were used to assess the severity of field inhomogeneity and suppress the residual phase in the phase mask induced by the off‐resonance effect. Volume segmentation of brain tissue was used to reduce the signal loss in the peripheral regions of the brain in the through‐plane mIP images and enable in‐plane mIP display of MRV.Results: Off‐resonance artifact in the brain regions with severe field inhomogeneity was effectively reduced by the LFG‐based phase suppression approach. Signal loss was reduced in the through‐plane mIP of MRV using volume segmentation of brain tissue prior to projection. In‐plane mIP of MRV also became feasible with volume segmentation.Conclusion: Off‐resonance artifacts and signal loss in mIP display of MRV can be effectively reduced through postprocessing. J. Magn. Reson. Imaging 2008;28:327–333.


  • Open Access

    Simultaneous acquisition of MR angiography and venography (MRAV)

    by Yiping P. Du, Zhaoyang Jin

    A dual‐echo pulse sequence for simultaneous acquisition of MR angiography and venography (MRAV) is developed. Data acquisition of the second echo for susceptibility‐weighted imaging–based MR venography is added to the conventional three‐dimensional (3D) time‐of‐flight (TOF) MRA pulse sequence. Using this dual‐echo acquisition approach, the venography data can be acquired without increasing the repetition time, and, therefore, the scan duration of routine TOF MRA scans is maintained. The feasibility of simultaneous acquisition of MRAV is presented in brain scans at different spatial resolutions. The effect of spatial resolution on vein‐to‐background contrast is also demonstrated. Venous contrast is improved in high‐resolution (0.52 × 0.52 × 1.6 mm3) images compared to that in standard‐resolution (0.78 × 0.78 × 1.6 mm3) images. This MRAV technique enables the acquisition of MR venography without the need of an extra scan or injection of contrast agent in routine clinical brain exams at 3T. Magn Reson Med 59:954–958, 2008.


  • Open Access

    Fast multislice mapping of the myelin water fraction using multicompartment analysis of T decay at 3T: A preliminary postmortem study

    by Yiping P. Du, Renxin Chu, Dosik Hwang, Mark S. Brown, Bette K. Kleinschmidt‐DeMasters, Debra Singel, Jack H. Simon

    Quantitative mapping of the myelin water content can provide significant insight into the pathophysiology of several white matter diseases, such as multiple sclerosis and leukoencephalopathies, and can potentially become a useful clinical tool for early diagnosis of these diseases. In this study, multicompartment analysis of T decay (MCAT2*) was used for the quantitative mapping of myelin water fraction (MWF). T decay of each voxel at multiple slice locations was acquired in fixed human brains using a multigradient‐echo (MGRE) pulse sequence with alternating readout gradient polarities. Compared to prior techniques using Carr‐Purcell‐Meiboom‐Gill (CPMG) acquisition, the MGRE acquisition approach has: 1) a very short first echo time (≈2 ms) and echo‐spacing (≈1 ms), which allows for the acquisition of multiple sampling points during the fast decay of the myelin water signal; 2) a low RF duty cycle, which is especially important for achieving acceptable specific absorption rate (SAR) levels at high field strengths. Multicompartment analysis was then applied to the T decay in each pixel using a 3‐pool model of white matter to detect the signal arising from the myelin water, myelinated axonal water, and mixed water compartments. Magn Reson Med 58:865–870, 2007.


  • Open Access

    Reducing susceptibility artifacts in fMRI using volume‐selective z‐shim compensation

    by Yiping P. Du, Manish Dalwani, Korey Wylie, Eric Claus, Jason R. Tregellas

    Susceptibility‐induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient‐echo‐based functional MRI (fMRI) studies. Although conventional z‐shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z‐shim technique with high imaging efficiency is presented in this study. In this technique, z‐shim compensations are applied only to a selective volume where the susceptibility artifact is severe. The results of an fMRI study (N = 6) demonstrate the feasibility of detecting the OFC activation with z‐shim in whole‐brain fMRI studies at a temporal resolution of 2 s. Magn Reson Med 57:396–404, 2007.


  • Anatomical and functional brain imaging using high-resolution echo-planar spectroscopic imaging at 1.5 Tesla

    by Weiliang Du, Gregory S. Karczmar, Stephen J. Uftring, Yiping P. Du

    High‐resolution echo‐planar spectroscopic imaging (EPSI) of water resonance (i.e. without water suppression) is proposed for anatomic and functional imaging of the human brain at 1.5 T. Water spectra with a resolution of 2.6 Hz and a bandwidth of 333 Hz were obtained in small voxels (1.7 × 1.7 × 3 mm3) across a single slice. Although water spectra appeared Lorentzian in most of the voxels in the brain, non‐Lorentzian broadening of the water resonance was observed in voxels containing blood vessels. In functional experiments with a motor task, robust activation in motor cortices was observed in high‐resolution T maps generated from the EPSI data. Shift of the water resonance frequency occurred during neuronal activation in motor cortices. The activation areas appeared to be more localized after excluding the voxels in which the lineshape of the water resonance had elevated T and became more non‐Lorentzian during the motor task. These preliminary results suggest that high‐resolution EPSI is a promising tool to study susceptibility‐related effects, such as BOLD contrast, for improved anatomical and functional imaging of the brain. Copyright © 2005 John Wiley & Sons, Ltd.


  • Open Access

    Fourier components of inhomogeneously broadened water resonances in breast: A new source of MRI contrast

    by Milica Medved, Gillian M. Newstead, Xiaobing Fan, Weiliang Du, Yiping P. Du, Peter M. MacEneaney, Rita M. Culp, Frederick Kelcz, Olufunmilayo I. Olopade, Marta A. Zamora, et al.

    High spectral and spatial resolution (HiSS) MR data were acquired at 1.5 T using echo-planar spectroscopic imaging from patients with suspicious breast lesions. The water resonances in small voxels are inhomogenously broadened and often have distinct components. Images were calculated with intensity proportional to the Fourier components of the water resonance in each voxel at different offsets from the peak frequency. The results demonstrate that in breast the off-peak Fourier component images of water are qualitatively different from those derived from the peak height of the water resonance. These differences most likely reflect underlying anatomy or physiology. In conventional images, the superposition of the various Fourier components of the water signal may cause loss of detail. The synthesis of water Fourier component images from high spectral and spatial resolution data may provide a new form of contrast, and increase sensitivity to subvoxel physiology and anatomy. Magn Reson Med 52:193–196, 2004.


  • An Accurate, Robust, and Computationally Efficient Navigator Algorithm for Measuring Diaphragm Positions # ?

    by Yiping Du, Manojkumar Saranathan, Thomas Foo

    International academic publisher with offices worldwide. Publishing more than 2,100 journals, over 4,000 new books each year, with a books backlist in excess of 60,000 specialist titles. We are one of the world’s leading publishers of scholarly journals, books, eBooks, textbooks and reference works


  • Open Access

    Reduction of spectral ghost artifacts in high‐resolution echo‐planar spectroscopic imaging of water and fat resonances

    by Weiliang Du, Yiping P. Du, Xiaobing Fan, Marta A. Zamora, Gregory S. Karczmar

    Echo-planar spectroscopic imaging (EPSI) can be used for fast spectroscopic imaging of water and fat resonances at high resolution to improve structural and functional imaging. Because of the use of oscillating gradients during the free induction decay (FID), spectra obtained with EPSI are often degraded by Nyquist ghost artifacts arising from the inconsistency between the odd and even echoes. The presence of the spectral ghost lines causes errors in the evaluation of the true spectral lines, and this degrades images derived from high-resolution EPSI data. A technique is described for reducing the spectral ghost artifacts in EPSI of water and fat resonances, using echo shift and zero-order phase corrections. These corrections are applied during the data postprocessing. This technique is demonstrated with EPSI data acquired from human brains and breasts at 1.5 Tesla and from a water phantom at 4.7 Tesla. Experimental results indicate that the present approach significantly reduces the intensities of spectral ghosts. This technique is most useful in conjunction with high-resolution EPSI of water and fat resonances, but is less applicable to EPSI of metabolites due to the complexity of the spectra. Magn Reson Med 49:1113–1120, 2003.


  • Prospective navigator gating with a dual acceptance window technique to reduce respiratory motion artifacts in 3D MR coronary angiography

    by Yiping P. Du

    A prospective navigator algorithm with a dual acceptance window (DAW) technique was developed to reduce image artifacts induced by respiratory motion without increasing imaging time. A phantom study...


  • Open Access

    Correction of concomitant magnetic field‐induced image artifacts in nonaxial echo‐planar imaging

    by Yiping P. Du, Xiaohong Joe Zhou, Matt A. Bernstein

    Echo‐planar images acquired in nonaxial planes are often distorted. Such image distortion has limited the applications of the echo‐planar imaging (EPI) technique. In this article, it is demonstrated that a considerable amount of the distortion is caused by the higher‐order magnetic field concomitant with the linear magnetic field gradient, or the concomitant magnetic field. The image distortion caused by the concomitant magnetic field is more prominent when a higher gradient amplitude is used for readout. It is also shown that the concomitant magnetic field can cause ghosting and blurring. A theoretical analysis is performed for the concomitant field effect in nonaxial EPI images. A point‐by‐point (or line‐by‐line) phase correction algorithm is developed to correct the image distortion, ghosting, and blurring. A postreconstruction processing algorithm is also developed to correct image distortion with much higher computational efficiency. Experimental results show that both correction methods effectively reduce the image distortion in coronal or sagittal images. Magn Reson Med 48:509–515, 2002.