Tibor Juhasz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tibor Juhasz has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Hui Sun
Alcon LenSx Inc., Aliso Viejo, California 92656, USA
8 shared publicationsRonald M. Kurtz
Univ. of California, Irvine (United States)
4 shared publicationsDongyul Chai
Department of Ophthalmology, University of California-Irvine, Irvine, California 92626, USA
3 shared publicationsGautam Chaudhary
Department of Ophthalmology, University of California—Irvine, Irvine, California
3 shared publicationsBin Rao
2 shared publicationsEric Mikula
Department of Biomedical Engineering, University of California—Irvine, Irvine, California
2 shared publications
Latest Publications
- 1 December 2018
- Published by Elsevier in Experimental Eye Research
- Vol. 177, 173-180
Collagen fiber crimping following in vivo UVA-induced corneal crosslinking
- 1 December 2018
- Published by Elsevier in Experimental Eye Research
- Vol. 177, 173-180
Collagen fiber crimping following in vivo UVA-induced corneal crosslinking
- 27 October 2012
- Published by Springer Nature
- p. 39-48
Challenges of Femtosecond Laser Technologies for Cataract Surgery
- 27 October 2012
- Published by Springer Nature
- p. 39-48
Challenges of Femtosecond Laser Technologies for Cataract Surgery
- Open Access
- 1 July 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (7) , 0780011-6
Finite element model of the temperature increase in excised porcine cadaver iris during direct illumination by femtosecond laser pulses
Laser in situ keratomileusis (LASIK) is the most common refractive surgical procedure in the United States today. This procedure involves cutting a thin flap in the cornea either with a fine blade (microkeratome) or a femtosecond laser (so-called bladeless method) in order to expose the stromal bed.1 2. 3. – 4 Femtosecond laser systems have successfully entered the refractive surgery market, primarily due to their enhanced precision and minimized collateral tissue effects.5 6. 7. 8. 9. – 10 Diode pumped all-solid-state femtosecond lasers are now also commonly used or being investigated to perform additional procedures, such as corneal transplants and fs-lentotomy.11 12. 13. 14. – 15 The improvement of the technology resulted in a progressive increase of the repetition emission frequency up to 60 and 150 kHz or even higher repetition rates.16 17. – 18 One of the most popular commercial systems is the 60 kHz FS 60 Laser (AMO Inc., Santa Ana, CA). However, the higher repetition rate will increase the average laser power reaching both the retina and iris during LASIK surgery, raising the potential risk of thermal damage. Preliminary estimates suggest that almost half of laser energy passes beyond the cornea with potential effects on the retina and iris.19 20. – 21 The temperature increase in human cadaver retina was investigated via ex vivo experiments and simulation by our group previously.19 To study the temperature increase of the iris is also reasonable, since during the LASIK surgery the iris is closer to the focus of the laser beam than the retina. Although the iris does not absorb laser energy as strongly as the retina does, it is also pigmented and absorbs the laser energy. In order to model the laser exposure of the iris during femtosecond laser corneal surgery, we have developed a two-dimensional computer simulation using the COMSOL finite element software (Comsol Inc., Burlington, MA). To validate our simulation results ex vivo experiments were performed using porcine cadaver iris where the temperature increase was measured by an infrared thermal camera. Different laser energies were used for both the simulation and the ex vivo experiments. The temperature of the samples was simulated and measured at every second throughout the 24 second long flap procedure. As the extension of the model, we also simulated the situation for other femtosecond laser systems, namely the 150 kHz iFS Advanced Femtosecond Laser (AMO Inc., Santa Ana, CA), the FEMTEC system (Technolas Perfect Vision Inc., Heidelberg, Germany), and the VisuMax system (Carl Zeiss Inc., Jena, Germany).
- 1 July 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (7) , 0780011-6
Open AccessFinite element model of the temperature increase in excised porcine cadaver iris during direct illumination by femtosecond laser pulses
Laser in situ keratomileusis (LASIK) is the most common refractive surgical procedure in the United States today. This procedure involves cutting a thin flap in the cornea either with a fine blade (microkeratome) or a femtosecond laser (so-called bladeless method) in order to expose the stromal bed.1 2. 3. – 4 Femtosecond laser systems have successfully entered the refractive surgery market, primarily due to their enhanced precision and minimized collateral tissue effects.5 6. 7. 8. 9. – 10 Diode pumped all-solid-state femtosecond lasers are now also commonly used or being investigated to perform additional procedures, such as corneal transplants and fs-lentotomy.11 12. 13. 14. – 15 The improvement of the technology resulted in a progressive increase of the repetition emission frequency up to 60 and 150 kHz or even higher repetition rates.16 17. – 18 One of the most popular commercial systems is the 60 kHz FS 60 Laser (AMO Inc., Santa Ana, CA). However, the higher repetition rate will increase the average laser power reaching both the retina and iris during LASIK surgery, raising the potential risk of thermal damage. Preliminary estimates suggest that almost half of laser energy passes beyond the cornea with potential effects on the retina and iris.19 20. – 21 The temperature increase in human cadaver retina was investigated via ex vivo experiments and simulation by our group previously.19 To study the temperature increase of the iris is also reasonable, since during the LASIK surgery the iris is closer to the focus of the laser beam than the retina. Although the iris does not absorb laser energy as strongly as the retina does, it is also pigmented and absorbs the laser energy. In order to model the laser exposure of the iris during femtosecond laser corneal surgery, we have developed a two-dimensional computer simulation using the COMSOL finite element software (Comsol Inc., Burlington, MA). To validate our simulation results ex vivo experiments were performed using porcine cadaver iris where the temperature increase was measured by an infrared thermal camera. Different laser energies were used for both the simulation and the ex vivo experiments. The temperature of the samples was simulated and measured at every second throughout the 24 second long flap procedure. As the extension of the model, we also simulated the situation for other femtosecond laser systems, namely the 150 kHz iFS Advanced Femtosecond Laser (AMO Inc., Santa Ana, CA), the FEMTEC system (Technolas Perfect Vision Inc., Heidelberg, Germany), and the VisuMax system (Carl Zeiss Inc., Jena, Germany).
- 14 June 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (8) , 081411-6
Evaluation of human sclera after femtosecond laser ablation using two photon and confocal microscopy
Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial thickness intrascleral channels can be created with a femtosecond laser operating at a wavelength of 1700 nm. Such channels have the potential to increase outflow facility and reduce elevated IOP. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in human cadaver eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such channels. This demonstrates that concept of integrating femtosecond laser surgery, and two-photon and confocal imaging has the future potential for image-guided high-precision surgery in transparent and translucent tissue.
- 14 June 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (8) , 081411-6
Evaluation of human sclera after femtosecond laser ablation using two photon and confocal microscopy
Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial thickness intrascleral channels can be created with a femtosecond laser operating at a wavelength of 1700 nm. Such channels have the potential to increase outflow facility and reduce elevated IOP. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in human cadaver eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such channels. This demonstrates that concept of integrating femtosecond laser surgery, and two-photon and confocal imaging has the future potential for image-guided high-precision surgery in transparent and translucent tissue.
- 1 February 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (2) , 386-391
Temperature increase in porcine cadaver iris during direct illumination by femtosecond laser pulses
To measure the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser as a model for laser exposure of the iris during femtosecond laser corneal surgery. Department of Ophthalmology, University of California-Irvine, Irvine, California, USA. Experimental study. The temperature increase induced by a 60 kHz commercial femtosecond laser in porcine cadaver iris was measured in situ using an infrared thermal imaging camera at pulse energy levels ranging from 1 to 2 μJ (corresponding approximately to surgical energies of 2 to 4 μJ per laser pulse). Temperature increases up to 2.3°C (corresponding to 2 μJ and 24-second illumination) were observed in the porcine cadaver iris with little variation in temperature profiles between specimens for the same laser energy illumination. The 60 kHz commercial femtosecond laser operating with pulse energies at approximately the lower limit of the range evaluated in this study would be expected to result in a 1.2°C temperature increase and therefore does not present a safety hazard to the iris. No author has a financial or proprietary interest in any material or method mentioned.
- 1 February 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (2) , 386-391
Temperature increase in porcine cadaver iris during direct illumination by femtosecond laser pulses
To measure the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser as a model for laser exposure of the iris during femtosecond laser corneal surgery. Department of Ophthalmology, University of California-Irvine, Irvine, California, USA. Experimental study. The temperature increase induced by a 60 kHz commercial femtosecond laser in porcine cadaver iris was measured in situ using an infrared thermal imaging camera at pulse energy levels ranging from 1 to 2 μJ (corresponding approximately to surgical energies of 2 to 4 μJ per laser pulse). Temperature increases up to 2.3°C (corresponding to 2 μJ and 24-second illumination) were observed in the porcine cadaver iris with little variation in temperature profiles between specimens for the same laser energy illumination. The 60 kHz commercial femtosecond laser operating with pulse energies at approximately the lower limit of the range evaluated in this study would be expected to result in a 1.2°C temperature increase and therefore does not present a safety hazard to the iris. No author has a financial or proprietary interest in any material or method mentioned.
- Open Access
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (10) , 108001-9
Simulation of the temperature increase in human cadaver retina during direct illumination by 150-kHz femtosecond laser pulses
Multiple commercial femtosecond laser systems are approved by the U.S. Food and Drug Administration for refractive surgery.1, 2, 3 This procedure involves cutting of a thin flap in the cornea either with a fine blade (microkeratome) or a femtosecond laser (so called bladeless method) in order to expose the stromal bed for the excimer laser ablation in a laser in situ keratomileusis (LASIK) procedure, which is the most common refractive surgical method in the United States (US) today.4, 5, 6, 7, 8 Due to the advantage of the enhanced precision and minimized collateral tissue effects, femtosecond lasers have displaced the mechanical microkeratome as the dominant tool for LASIK flap creation in the US over the past decade. 9, 10, 11, 12, 13, 14, 15 Diode pumped all-solid-state femtosecond lasers are now also commonly used to perform corneal transplants16, 17, 18 or being investigated to perform additional procedures, such as fs-lentotomy.19, 20, 21
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (10) , 108001-9
Open AccessSimulation of the temperature increase in human cadaver retina during direct illumination by 150-kHz femtosecond laser pulses
Multiple commercial femtosecond laser systems are approved by the U.S. Food and Drug Administration for refractive surgery.1, 2, 3 This procedure involves cutting of a thin flap in the cornea either with a fine blade (microkeratome) or a femtosecond laser (so called bladeless method) in order to expose the stromal bed for the excimer laser ablation in a laser in situ keratomileusis (LASIK) procedure, which is the most common refractive surgical method in the United States (US) today.4, 5, 6, 7, 8 Due to the advantage of the enhanced precision and minimized collateral tissue effects, femtosecond lasers have displaced the mechanical microkeratome as the dominant tool for LASIK flap creation in the US over the past decade. 9, 10, 11, 12, 13, 14, 15 Diode pumped all-solid-state femtosecond lasers are now also commonly used to perform corneal transplants16, 17, 18 or being investigated to perform additional procedures, such as fs-lentotomy.19, 20, 21
- 25 August 2010
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (7) , 647-651
In vivo femtosecond laser subsurface scleral treatment in rabbit eyes
Background and Objectives: The progression of glaucoma can be reduced or delayed by reducing intraocular pressure (IOP). The properties of femtosecond laser surgery, such as markedly reduced collateral tissue damage, coupled with the ability to achieve isolated subsurface surgical effects in the sclera, make this technology a promising candidate in glaucoma management. In this pilot study we demonstrate the in vivo creation of partial thickness subsurface drainage channels with the femtosecond laser in the sclera of rabbit eyes in order to increase aqueous humor (AH) outflow.Study Design/Materials and Methods: A femtosecond laser beam tuned to a 1.7 µm wavelength was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of one eye of each of the four rabbits included in this pilot study. IOP was measured before and 20 minutes after the laser treatment to evaluate the acute effect of the procedure.Results: OCT images verified the creation of the partial thickness subsurface scleral channels in the eyes of the in vivo rabbits. Comparison of pre‐ and postoperative IOP measurements in treated and control eyes revealed a reduction in the intraocular pressure due to the increased rate of AH outflow resulted in by the presence of the partial thickness scleral channels.Conclusions: The creation of partial thickness subsurface drainage channels was demonstrated in the sclera of in vivo rabbit eyes with a 1.7 µm wavelength femtosecond laser. Reduction in IOP achieved by the partial thickness channels suggests potential utility in the treatment of elevated IOP. Lasers Surg. Med. 42:647–651, 2010.
- 25 August 2010
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (7) , 647-651
In vivo femtosecond laser subsurface scleral treatment in rabbit eyes
Background and Objectives: The progression of glaucoma can be reduced or delayed by reducing intraocular pressure (IOP). The properties of femtosecond laser surgery, such as markedly reduced collateral tissue damage, coupled with the ability to achieve isolated subsurface surgical effects in the sclera, make this technology a promising candidate in glaucoma management. In this pilot study we demonstrate the in vivo creation of partial thickness subsurface drainage channels with the femtosecond laser in the sclera of rabbit eyes in order to increase aqueous humor (AH) outflow.Study Design/Materials and Methods: A femtosecond laser beam tuned to a 1.7 µm wavelength was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of one eye of each of the four rabbits included in this pilot study. IOP was measured before and 20 minutes after the laser treatment to evaluate the acute effect of the procedure.Results: OCT images verified the creation of the partial thickness subsurface scleral channels in the eyes of the in vivo rabbits. Comparison of pre‐ and postoperative IOP measurements in treated and control eyes revealed a reduction in the intraocular pressure due to the increased rate of AH outflow resulted in by the presence of the partial thickness scleral channels.Conclusions: The creation of partial thickness subsurface drainage channels was demonstrated in the sclera of in vivo rabbit eyes with a 1.7 µm wavelength femtosecond laser. Reduction in IOP achieved by the partial thickness channels suggests potential utility in the treatment of elevated IOP. Lasers Surg. Med. 42:647–651, 2010.
- 1 April 2010
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 26 (4) , 272-277
Temperature Increase in Human Cadaver Retina During Direct Illumination by Femtosecond Laser Pulses
PURPOSE: Femtosecond lasers have been approved by the US Food and Drug Administration for ophthalmic surgery, including use in creating corneal flaps in LASIK surgery. During normal operation, approximately 50% to 60% of laser energy may pass beyond the cornea, with potential effects on the retina. As a model for retinal laser exposure during femtosecond corneal surgery, we measured the temperature rise in human cadaver retinas during direct illumination by the laser.METHODS: The temperature increase induced by a 150-kHz iFS Advanced Femtosecond Laser (Abbott Medical Optics) in human cadaver retinas was measured in situ using an infrared thermal imaging camera. To model the geometry of the eye during the surgery, an approximate 11×11-mm excised section of human cadaver retina was placed 17 mm behind the focus of the laser beam. The temperature field was observed in 10 cadaver retina samples at energy levels ranging from 0.4 to 1.6 µJ (corresponding approximately to surgical energies of 0.8 to 3.2 µJ per pulse).RESULTS: Maximal temperature increases up to 1.15°C (corresponding to 3.2 µJ and 52-second illumination) were observed in the cadaver retina sections with little variation in temperature profiles between specimens for the same laser energy illumination.CONCLUSIONS: The commercial iFS Advanced Femtosecond Laser operating with pulse energies at approximately the lower limit of the range evaluated in this study would be expected to result in a 0.2°C temperature increase and do not therefore present a safety hazard to the retina. [J Refract Surg. 2010;26:272–277.]
- 1 April 2010
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 26 (4) , 272-277
Temperature Increase in Human Cadaver Retina During Direct Illumination by Femtosecond Laser Pulses
PURPOSE: Femtosecond lasers have been approved by the US Food and Drug Administration for ophthalmic surgery, including use in creating corneal flaps in LASIK surgery. During normal operation, approximately 50% to 60% of laser energy may pass beyond the cornea, with potential effects on the retina. As a model for retinal laser exposure during femtosecond corneal surgery, we measured the temperature rise in human cadaver retinas during direct illumination by the laser.METHODS: The temperature increase induced by a 150-kHz iFS Advanced Femtosecond Laser (Abbott Medical Optics) in human cadaver retinas was measured in situ using an infrared thermal imaging camera. To model the geometry of the eye during the surgery, an approximate 11×11-mm excised section of human cadaver retina was placed 17 mm behind the focus of the laser beam. The temperature field was observed in 10 cadaver retina samples at energy levels ranging from 0.4 to 1.6 µJ (corresponding approximately to surgical energies of 0.8 to 3.2 µJ per pulse).RESULTS: Maximal temperature increases up to 1.15°C (corresponding to 3.2 µJ and 52-second illumination) were observed in the cadaver retina sections with little variation in temperature profiles between specimens for the same laser energy illumination.CONCLUSIONS: The commercial iFS Advanced Femtosecond Laser operating with pulse energies at approximately the lower limit of the range evaluated in this study would be expected to result in a 0.2°C temperature increase and do not therefore present a safety hazard to the retina. [J Refract Surg. 2010;26:272–277.]
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7548, 75484I
Evaluation of laser ablation of knee cartilage as an alternative to microfracture surgery: pilot investigations
An emerging clinical treatment option for articular cartilage injury includes bone marrow stimulation techniques, such as microfracture, which has grown increasingly popular among athletes. During the microfracture procedure, the surgeon penetrates the subchondral bone with an awl and creates "microholes" deep enough to ensure bleeding from the bone marrow. This procedure triggers a spontaneous repair response that results in the formation of fibrocartilaginous repair tissue. This preliminary study aimed to evaluate the potential use of femtosecond lasers and Erbium:YAG lasers as alternatives to microfracture surgery of the knee by assessing the effects of ablation on bovine femoral condyles. Bovine femoral condyles were obtained and 8mm cube blocks were extracted. The specimen were ablated with various laser dosimetry parameters and observed using a high power dissecting microscope to examine the effects of the lasers. Further imaging with conventional histology (hematoxylin and eosin staining) was done to provide more accurate information. Preliminary results show some carbonization but demonstrate little thermal damage to surrounding tissues. The femtosecond laser offers a more precise and efficient ablation than the Erbium:YAG laser, but both are demonstrated to be possible alternatives to the surgical-skill dependent microfracture procedure.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7548, 75484I
Evaluation of laser ablation of knee cartilage as an alternative to microfracture surgery: pilot investigations
An emerging clinical treatment option for articular cartilage injury includes bone marrow stimulation techniques, such as microfracture, which has grown increasingly popular among athletes. During the microfracture procedure, the surgeon penetrates the subchondral bone with an awl and creates "microholes" deep enough to ensure bleeding from the bone marrow. This procedure triggers a spontaneous repair response that results in the formation of fibrocartilaginous repair tissue. This preliminary study aimed to evaluate the potential use of femtosecond lasers and Erbium:YAG lasers as alternatives to microfracture surgery of the knee by assessing the effects of ablation on bovine femoral condyles. Bovine femoral condyles were obtained and 8mm cube blocks were extracted. The specimen were ablated with various laser dosimetry parameters and observed using a high power dissecting microscope to examine the effects of the lasers. Further imaging with conventional histology (hematoxylin and eosin staining) was done to provide more accurate information. Preliminary results show some carbonization but demonstrate little thermal damage to surrounding tissues. The femtosecond laser offers a more precise and efficient ablation than the Erbium:YAG laser, but both are demonstrated to be possible alternatives to the surgical-skill dependent microfracture procedure.
- 1 January 2008
- Published by Optica Publishing Group
- p. FTuE1
Application of Femtosecond Laser Surgery for the Treatment of Glaucoma
Femtosecond laser pulses can be used to create partial thickness scleral channels that drain aqueous humor into the sub-conjunctival space, showing potential for the treatment of glaucoma. Treatment techniques and in vivo results are discussed.
- 1 January 2008
- Published by Optica Publishing Group
- p. FTuE1
Application of Femtosecond Laser Surgery for the Treatment of Glaucoma
Femtosecond laser pulses can be used to create partial thickness scleral channels that drain aqueous humor into the sub-conjunctival space, showing potential for the treatment of glaucoma. Treatment techniques and in vivo results are discussed.