Christopher J. Hardy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christopher J. Hardy has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Manojkumar Saranathan
Indian Institute of Science, Bangalore, India
3 shared publicationsPaul A. Bottomley
Johns Hopkins University Department of Radiology, Baltimore, Maryland, USA
3 shared publicationsRobert D. Darrow
GE Global Research Center, Niskayuna, New York
2 shared publicationsYudong Zhu
GE Global Research Center, Niskayuna, New York
2 shared publicationsBruce D. Collick
GE Healthcare, Waukesha, Wisconsin, USA
1 shared publicationBulent Aksel
GE Global Research, Niskayuna, New York 12309, USA
1 shared publication
Latest Publications
- Open Access
- 20 July 2007
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (1) , 134-143
Local planar gradients with order‐of‐magnitude strength and speed advantage
A three‐axis uniplanar gradient coil was designed and built to provide order‐of‐magnitude increases in gradient strength of up to 500 mT/m on the x‐ and y‐axes, and 1000 mT/m for the z‐axis at 640 A input over a limited FOV (∼16 cm) for superficial regions, compared to conventional gradient coils, with significant gradient strengths extending deeper into the body. The gradient set is practically accommodated in the bore of a conventional whole‐body, cylindrical‐geometry MRI scanner, and operated using standard gradient supplies. The design was optimized for gradient linearity over a restricted volume while accounting for the practical problems of torque and heating. Tests at 320 A demonstrated up to 420‐mT/m gradients near the surface at efficiencies of up to 1.4 mT/m/A. A new true 2D gradient‐nonlinearity correction algorithm was developed to rectify gradient nonlinearities and considerably expand the imageable volumes. The gradient system and correction algorithm were implemented in a standard 1.5T scanner and demonstrated by high‐resolution imaging of phantoms and humans. Magn Reson Med 58:134–143, 2007.
- 20 July 2007
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (1) , 134-143
Open AccessLocal planar gradients with order‐of‐magnitude strength and speed advantage
A three‐axis uniplanar gradient coil was designed and built to provide order‐of‐magnitude increases in gradient strength of up to 500 mT/m on the x‐ and y‐axes, and 1000 mT/m for the z‐axis at 640 A input over a limited FOV (∼16 cm) for superficial regions, compared to conventional gradient coils, with significant gradient strengths extending deeper into the body. The gradient set is practically accommodated in the bore of a conventional whole‐body, cylindrical‐geometry MRI scanner, and operated using standard gradient supplies. The design was optimized for gradient linearity over a restricted volume while accounting for the practical problems of torque and heating. Tests at 320 A demonstrated up to 420‐mT/m gradients near the surface at efficiencies of up to 1.4 mT/m/A. A new true 2D gradient‐nonlinearity correction algorithm was developed to rectify gradient nonlinearities and considerably expand the imageable volumes. The gradient system and correction algorithm were implemented in a standard 1.5T scanner and demonstrated by high‐resolution imaging of phantoms and humans. Magn Reson Med 58:134–143, 2007.
- Open Access
- 23 September 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (4) , 878-884
Large field‐of‐view real‐time MRI with a 32‐channel system
The emergence of parallel MRI techniques and new applications for real‐time interactive MRI underscores the need to evaluate performance gained by increasing the capability of MRI phased‐array systems beyond the standard four to eight high‐bandwidth channels. Therefore, to explore the advantages of highly parallel MRI a 32‐channel 1.5 T MRI system and 32‐element torso phased arrays were designed and constructed for real‐time interactive MRI. The system was assembled from multiple synchronized scanner‐receiver subsystems. Software was developed to coordinate across subsystems the real‐time acquisition, reconstruction, and display of 32‐channel images. Real‐time, large field‐of‐view (FOV) body‐survey imaging was performed using interleaved echo‐planar and single‐shot fast‐spin‐echo pulse sequences. A new method is demonstrated for augmenting parallel image acquisition by independently offsetting the frequency of different array elements (FASSET) to variably shift their FOV. When combined with conventional parallel imaging techniques, image acceleration factors of up to 4 were investigated. The use of a large number of coils allowed the FOV to be doubled in two dimensions during rapid imaging, with no degradation of imaging time or spatial resolution. The system provides a platform for evaluating the applications of many‐channel real‐time MRI, and for understanding the factors that optimize the choice of array size. Magn Reson Med 52:878–884, 2004.
- 23 September 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (4) , 878-884
Open AccessLarge field‐of‐view real‐time MRI with a 32‐channel system
The emergence of parallel MRI techniques and new applications for real‐time interactive MRI underscores the need to evaluate performance gained by increasing the capability of MRI phased‐array systems beyond the standard four to eight high‐bandwidth channels. Therefore, to explore the advantages of highly parallel MRI a 32‐channel 1.5 T MRI system and 32‐element torso phased arrays were designed and constructed for real‐time interactive MRI. The system was assembled from multiple synchronized scanner‐receiver subsystems. Software was developed to coordinate across subsystems the real‐time acquisition, reconstruction, and display of 32‐channel images. Real‐time, large field‐of‐view (FOV) body‐survey imaging was performed using interleaved echo‐planar and single‐shot fast‐spin‐echo pulse sequences. A new method is demonstrated for augmenting parallel image acquisition by independently offsetting the frequency of different array elements (FASSET) to variably shift their FOV. When combined with conventional parallel imaging techniques, image acceleration factors of up to 4 were investigated. The use of a large number of coils allowed the FOV to be doubled in two dimensions during rapid imaging, with no degradation of imaging time or spatial resolution. The system provides a platform for evaluating the applications of many‐channel real‐time MRI, and for understanding the factors that optimize the choice of array size. Magn Reson Med 52:878–884, 2004.
- Open Access
- 22 January 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (2) , 170-176
Coronary MR angiography: Respiratory motion correction with BACSPIN
Purpose To improve the signal‐to‐noise ratio (SNR) of breath‐held coronary magnetic resonance angiography (CMRA) without increasing the number or duration of breath holds. Materials and Methods In this BACSPIN (Breathing AutoCorrection with SPiral INterleaves) technique, a single breath‐held electrocardiogram (ECG)‐gated multi‐slice interleaved‐spiral data set is acquired, followed by repeated imaging of the same slices during free breathing. Each spiral interleaf from the breath‐held data set is used as a standard for comparison with corresponding acquisitions at the same interleaf angle during free breathing. The most closely matched acquisitions are incorporated into a multi‐slice, multi‐average data set with increasing SNR over time. In‐plane translations of the coronary artery can be measured and compensated for each accepted acquisition before combination with the other acquisitions. Results CMRA was performed on six volunteers, with improved SNR and minimal motional blurring. In some cases, breath holding could be dispensed with completely and the average respiratory position used as a reference. Conclusion BACSPIN provides a promising method for CMRA with improved SNR and limited breath‐holding requirements. J. Magn. Reson. Imaging 2003;17:170–176.
- 22 January 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (2) , 170-176
Open AccessCoronary MR angiography: Respiratory motion correction with BACSPIN
Purpose To improve the signal‐to‐noise ratio (SNR) of breath‐held coronary magnetic resonance angiography (CMRA) without increasing the number or duration of breath holds. Materials and Methods In this BACSPIN (Breathing AutoCorrection with SPiral INterleaves) technique, a single breath‐held electrocardiogram (ECG)‐gated multi‐slice interleaved‐spiral data set is acquired, followed by repeated imaging of the same slices during free breathing. Each spiral interleaf from the breath‐held data set is used as a standard for comparison with corresponding acquisitions at the same interleaf angle during free breathing. The most closely matched acquisitions are incorporated into a multi‐slice, multi‐average data set with increasing SNR over time. In‐plane translations of the coronary artery can be measured and compensated for each accepted acquisition before combination with the other acquisitions. Results CMRA was performed on six volunteers, with improved SNR and minimal motional blurring. In some cases, breath holding could be dispensed with completely and the average respiratory position used as a reference. Conclusion BACSPIN provides a promising method for CMRA with improved SNR and limited breath‐holding requirements. J. Magn. Reson. Imaging 2003;17:170–176.
- 1 December 2000
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 44 (6) , 940-946
Coronary angiography by real-time MRI with adaptive averaging
Cardiac and respiratory motion present significant challenges for MR coronary angiography, which have not been completely resolved to date by either breath‐holding or respiratory navigation. Adaptive averaging during real‐time MRI may provide a useful alternative to these techniques. In this method, cross‐correlation is used to automatically identify those real‐time imaging frames in which the vessel is present, and to determine the location of the vessel within each frame. This information is then used for selective averaging of frames to increase the signal‐to‐noise ratio and to improve visualization of the vessel. The correlation theorem was employed to raise the speed of this algorithm by up to two orders of magnitude. Segmenting data collection and reconstruction into subimages allows the extension of this technique to higher spatial resolution. Adaptive averaging provides a robust method for coronary MRI which requires no breath‐holding, navigation, or ECG gating. Magn Reson Med 44:940–946, 2000.
- 1 December 2000
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 44 (6) , 940-946
Coronary angiography by real-time MRI with adaptive averaging
Cardiac and respiratory motion present significant challenges for MR coronary angiography, which have not been completely resolved to date by either breath‐holding or respiratory navigation. Adaptive averaging during real‐time MRI may provide a useful alternative to these techniques. In this method, cross‐correlation is used to automatically identify those real‐time imaging frames in which the vessel is present, and to determine the location of the vessel within each frame. This information is then used for selective averaging of frames to increase the signal‐to‐noise ratio and to improve visualization of the vessel. The correlation theorem was employed to raise the speed of this algorithm by up to two orders of magnitude. Segmenting data collection and reconstruction into subimages allows the extension of this technique to higher spatial resolution. Adaptive averaging provides a robust method for coronary MRI which requires no breath‐holding, navigation, or ECG gating. Magn Reson Med 44:940–946, 2000.
- 1 May 1988
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 63 (9) , 4741-4743
Off-axis spatial localization with frequency modulated nuclear magnetic resonance rotating ( ρ) pulses
- 1 May 1988
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 63 (9) , 4741-4743
Off-axis spatial localization with frequency modulated nuclear magnetic resonance rotating ( ρ) pulses
- 1 November 1987
- Published by Wiley in Medical Physics
- Vol. 14 (6) , 1091
Reply to comments of Akber