Local planar gradients with order‐of‐magnitude strength and speed advantage
Open Access
- 20 July 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (1) , 134-143
Abstract
A three‐axis uniplanar gradient coil was designed and built to provide order‐of‐magnitude increases in gradient strength of up to 500 mT/m on the x‐ and y‐axes, and 1000 mT/m for the z‐axis at 640 A input over a limited FOV (∼16 cm) for superficial regions, compared to conventional gradient coils, with significant gradient strengths extending deeper into the body. The gradient set is practically accommodated in the bore of a conventional whole‐body, cylindrical‐geometry MRI scanner, and operated using standard gradient supplies. The design was optimized for gradient linearity over a restricted volume while accounting for the practical problems of torque and heating. Tests at 320 A demonstrated up to 420‐mT/m gradients near the surface at efficiencies of up to 1.4 mT/m/A. A new true 2D gradient‐nonlinearity correction algorithm was developed to rectify gradient nonlinearities and considerably expand the imageable volumes. The gradient system and correction algorithm were implemented in a standard 1.5T scanner and demonstrated by high‐resolution imaging of phantoms and humans. Magn Reson Med 58:134–143, 2007.Keywords
This publication has 12 references indexed in Scilit:
- Experimental determination of human peripheral nerve stimulation thresholds in a 3‐axis planar gradient systemMagnetic Resonance in Medicine, 2009
- Local planar gradients with order‐of‐magnitude strength and speed advantageMagnetic Resonance in Medicine, 2007
- Design and implementation of a uniplanar gradient field coil for magnetic resonance imagingConcepts in Magnetic Resonance Part B, 2004
- Design of biplanar gradient coils for magnetic resonance imaging of the human torso and limbsMagnetic Resonance Imaging, 1999
- Three-dimensional tracking of axonal projections in the brain by magnetic resonance imagingAnnals of Neurology, 1999
- Fast magnetic resonance imaging of the heartEuropean Journal of Radiology, 1999
- Clinical utility of diffusion‐weighted magnetic resonance imaging in the assessment of ischemic strokeAnnals of Neurology, 1997
- A new design for a three‐channel surface gradient coil employing a three‐dimensional finite element modelMagnetic Resonance in Medicine, 1996
- Gradient coil design: A review of methodsMagnetic Resonance Imaging, 1993
- A novel type of surface gradient coilJournal of Magnetic Resonance (1969), 1991