Adrienne N. Dula
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adrienne N. Dula has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Blake E. Dewey
National Institutes of Health, NINDS, Vanderbilt University Medical Center, Nashville, TN, USA
2 shared publicationsSeth A. Smith
Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
2 shared publicationsSiddharama Pawate
Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, USA
2 shared publications- Benjamin N. Conrad
Neuroscience Graduate Program, Vanderbilt Brain Institute, Vanderbilt University Medical Center, Nashville, TN, USA
1 shared publication Bennett A. Landman
Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee, USA
1 shared publication- David R Pennell
Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
1 shared publication
Latest Publications
- 26 July 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 29 (9) , 1249-1257
Chemical exchange saturation transfer of the cervical spinal cord at 7 T
High‐magnetic‐field (7 T) chemical exchange saturation transfer (CEST) MRI provides information on the tissue biochemical environment. Multiple sclerosis (MS) affects the entire central nervous system, including the spinal cord. Optimal CEST saturation parameters found via simulation were implemented for CEST MRI in 10 healthy controls and 10 patients with MS, and the results were examined using traditional asymmetry analysis and a Lorentzian fitting method. In addition, T1‐ and T2*‐weighted images were acquired for lesion localization and the transmitted B1+ field was evaluated to guide imaging parameters. Distinct spectral features for all tissue types studied were found both up‐ and downfield from the water resonance. The z spectra in healthy subjects had the expected z spectral shape with CEST effects apparent from 2.0 to 4.5 ppm. The z spectra from patients with MS demonstrated deviations from this expected normal shape, indicating this method's sensitivity to known pathology as well as to tissues appearing normal on conventional MRI. Examination of the calculated CESTasym revealed increased asymmetry around the amide proton resonance (Δω = 3.5 ppm), but it was apparent that this measure is complicated by detail in the CEST spectrum upfield from water, which is expected to result from the nuclear Overhauser effect. The z spectra upfield (negative ppm range) were also distinct between healthy and diseased tissue, and could not be ignored, particularly when considering the conventional asymmetry analysis used to quantify the CEST effect. For all frequencies greater than +1 ppm, the Lorentzian differences (and z spectra) for lesions and normal‐appearing white matter were distinct from those for healthy white matter. The increased frequency separation and signal‐to‐noise ratio, in concert with prolonged T1 at 7 T, resulted in signal enhancements necessary to detect subtle tissue changes not possible at lower field strengths. This study presents CEST imaging metrics that may be sensitive to the extensive and temporally varying biochemical neuropathology of MS in the spinal cord. Copyright © 2016 John Wiley & Sons, Ltd.
- 26 July 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 29 (9) , 1249-1257
Chemical exchange saturation transfer of the cervical spinal cord at 7 T
High‐magnetic‐field (7 T) chemical exchange saturation transfer (CEST) MRI provides information on the tissue biochemical environment. Multiple sclerosis (MS) affects the entire central nervous system, including the spinal cord. Optimal CEST saturation parameters found via simulation were implemented for CEST MRI in 10 healthy controls and 10 patients with MS, and the results were examined using traditional asymmetry analysis and a Lorentzian fitting method. In addition, T1‐ and T2*‐weighted images were acquired for lesion localization and the transmitted B1+ field was evaluated to guide imaging parameters. Distinct spectral features for all tissue types studied were found both up‐ and downfield from the water resonance. The z spectra in healthy subjects had the expected z spectral shape with CEST effects apparent from 2.0 to 4.5 ppm. The z spectra from patients with MS demonstrated deviations from this expected normal shape, indicating this method's sensitivity to known pathology as well as to tissues appearing normal on conventional MRI. Examination of the calculated CESTasym revealed increased asymmetry around the amide proton resonance (Δω = 3.5 ppm), but it was apparent that this measure is complicated by detail in the CEST spectrum upfield from water, which is expected to result from the nuclear Overhauser effect. The z spectra upfield (negative ppm range) were also distinct between healthy and diseased tissue, and could not be ignored, particularly when considering the conventional asymmetry analysis used to quantify the CEST effect. For all frequencies greater than +1 ppm, the Lorentzian differences (and z spectra) for lesions and normal‐appearing white matter were distinct from those for healthy white matter. The increased frequency separation and signal‐to‐noise ratio, in concert with prolonged T1 at 7 T, resulted in signal enhancements necessary to detect subtle tissue changes not possible at lower field strengths. This study presents CEST imaging metrics that may be sensitive to the extensive and temporally varying biochemical neuropathology of MS in the spinal cord. Copyright © 2016 John Wiley & Sons, Ltd.
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150633
Evaluation of 39 medical implants at 7.0 T
Objective:With increased signal to noise ratios, 7.0-T MRI has the potential to contribute unique information regarding anatomy and pathophysiology of a disease. However, concerns for the safety of subjects with metallic medical implants have hindered advancement in this field. The purpose of the present research was to evaluate the MRI safety for 39 commonly used medical implants at 7.0 T.Methods:Selected metallic implants were tested for magnetic field interactions, radiofrequency-induced heating and artefacts using standardized testing techniques.Results:5 of the 39 implants tested may be unsafe for subjects undergoing MRI at 7.0 T.Conclusion:Implants were deemed either “MR Conditional” or “MR Unsafe” for the 7.0-T MRI environment. Further research is needed to expand the existing database categorizing implants that are acceptable for patients referred for MRI examinations at 7.0 T.Advances in knowledge:Lack of MRI testing for common metallic medical implants limits the translational potential of 7.0-T...
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150633
Evaluation of 39 medical implants at 7.0 T
Objective:With increased signal to noise ratios, 7.0-T MRI has the potential to contribute unique information regarding anatomy and pathophysiology of a disease. However, concerns for the safety of subjects with metallic medical implants have hindered advancement in this field. The purpose of the present research was to evaluate the MRI safety for 39 commonly used medical implants at 7.0 T.Methods:Selected metallic implants were tested for magnetic field interactions, radiofrequency-induced heating and artefacts using standardized testing techniques.Results:5 of the 39 implants tested may be unsafe for subjects undergoing MRI at 7.0 T.Conclusion:Implants were deemed either “MR Conditional” or “MR Unsafe” for the 7.0-T MRI environment. Further research is needed to expand the existing database categorizing implants that are acceptable for patients referred for MRI examinations at 7.0 T.Advances in knowledge:Lack of MRI testing for common metallic medical implants limits the translational potential of 7.0-T...
- 1 April 2015
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 275 (1) , 255-261
Optimization of 7-T Chemical Exchange Saturation Transfer Parameters for Validation of Glycosaminoglycan and Amide Proton Transfer of Fibroglandular Breast Tissue
To (a) implement simulation-optimized chemical exchange saturation transfer (CEST) measurements sensitive to amide proton transfer (APT) and glycosaminoglycan (GAG) hydroxyl proton transfer effects in the human breast at 7 T and (b) determine the reliability of these techniques for evaluation of fibroglandular tissue in the healthy breast as a benchmark for future studies of pathologic findings. All human studies were institutional review board approved, were HIPAA compliant, and included informed consent. The CEST parameters of saturation duration (25 msec) and amplitude (1 μT) were chosen on the basis of simulation-driven optimization for APT contrast enhancement with the CEST effect quantified by using residuals of a Lorentzian fit. Optimized parameters were implemented at 7 T in 10 healthy women in two separate examinations to evaluate the reliability of CEST magnetic resonance (MR) imaging measurements in the breast. CEST z-spectra were acquired over saturation offset frequencies ranging between ±40 ppm by using a quadrature unilateral breast coil. The imaging-repeat imaging reliability was assessed in terms of the intraclass correlation coefficient, which indicates the ratio of between-subject variation to total variation. Simulations were performed of the Bloch equations with chemical exchange-guided selection of optimal values for pulse duration and amplitude, 25 msec and 1 μT, respectively. Reliability was evaluated by using intraclass correlation coefficients (95% confidence intervals), with acceptable results: 0.963 (95% confidence interval: 0.852, 0.991) and 0.903 (95% confidence interval: 0.609, 0.976) for APT and GAG, respectively. Simulations were used to derive optimal CEST preparation parameters to elicit maximal CEST contrast enhancement in healthy fibroglandular breast tissue due to APT at 7 T. By using these parameters, reproducible values were obtained for both the amide and hydroxyl protons from CEST MR imaging at 7 T and are feasible in the human breast.
- 1 April 2015
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 275 (1) , 255-261
Optimization of 7-T Chemical Exchange Saturation Transfer Parameters for Validation of Glycosaminoglycan and Amide Proton Transfer of Fibroglandular Breast Tissue
To (a) implement simulation-optimized chemical exchange saturation transfer (CEST) measurements sensitive to amide proton transfer (APT) and glycosaminoglycan (GAG) hydroxyl proton transfer effects in the human breast at 7 T and (b) determine the reliability of these techniques for evaluation of fibroglandular tissue in the healthy breast as a benchmark for future studies of pathologic findings. All human studies were institutional review board approved, were HIPAA compliant, and included informed consent. The CEST parameters of saturation duration (25 msec) and amplitude (1 μT) were chosen on the basis of simulation-driven optimization for APT contrast enhancement with the CEST effect quantified by using residuals of a Lorentzian fit. Optimized parameters were implemented at 7 T in 10 healthy women in two separate examinations to evaluate the reliability of CEST magnetic resonance (MR) imaging measurements in the breast. CEST z-spectra were acquired over saturation offset frequencies ranging between ±40 ppm by using a quadrature unilateral breast coil. The imaging-repeat imaging reliability was assessed in terms of the intraclass correlation coefficient, which indicates the ratio of between-subject variation to total variation. Simulations were performed of the Bloch equations with chemical exchange-guided selection of optimal values for pulse duration and amplitude, 25 msec and 1 μT, respectively. Reliability was evaluated by using intraclass correlation coefficients (95% confidence intervals), with acceptable results: 0.963 (95% confidence interval: 0.852, 0.991) and 0.903 (95% confidence interval: 0.609, 0.976) for APT and GAG, respectively. Simulations were used to derive optimal CEST preparation parameters to elicit maximal CEST contrast enhancement in healthy fibroglandular breast tissue due to APT at 7 T. By using these parameters, reproducible values were obtained for both the amide and hydroxyl protons from CEST MR imaging at 7 T and are feasible in the human breast.
- 12 February 2013
- Published by Wiley in Journal of Neuroimaging
- Vol. 23 (4) , 526-532
Application of Chemical Exchange Saturation Transfer (CEST) MRI for Endogenous Contrast at 7 Tesla
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) indirectly images exchangeable solute protons resonating at frequencies different than bulk water. These solute protons are selectively saturated using low bandwidth RF irradiation and saturation is transferred to bulk water protons via chemical exchange, resulting in an attenuation of the measured water proton signal. CEST MRI is an advanced MRI technique with wide application potential due to the ability to examine complex molecular contributions. CEST MRI at high field (7 Tesla [7 T]) will improve the overall results due to increase in signal, T1 relaxation time, and chemical shift dispersion. Increased field strength translates to enhanced quantification of the metabolite of interest, allowing more fundamental studies on underlying pathophysiology. CEST contrast is affected by several tissue properties, such as the concentrations of exchange partners and their rate of proton exchange, whose effects have been examined and explored in this review. We have highlighted the background of CEST MRI, typical implementation strategy, and complications at 7 T.
- 12 February 2013
- Published by Wiley in Journal of Neuroimaging
- Vol. 23 (4) , 526-532
Application of Chemical Exchange Saturation Transfer (CEST) MRI for Endogenous Contrast at 7 Tesla
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) indirectly images exchangeable solute protons resonating at frequencies different than bulk water. These solute protons are selectively saturated using low bandwidth RF irradiation and saturation is transferred to bulk water protons via chemical exchange, resulting in an attenuation of the measured water proton signal. CEST MRI is an advanced MRI technique with wide application potential due to the ability to examine complex molecular contributions. CEST MRI at high field (7 Tesla [7 T]) will improve the overall results due to increase in signal, T1 relaxation time, and chemical shift dispersion. Increased field strength translates to enhanced quantification of the metabolite of interest, allowing more fundamental studies on underlying pathophysiology. CEST contrast is affected by several tissue properties, such as the concentrations of exchange partners and their rate of proton exchange, whose effects have been examined and explored in this review. We have highlighted the background of CEST MRI, typical implementation strategy, and complications at 7 T.
- Open Access
- 22 March 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (3) , 831-838
Development of chemical exchange saturation transfer at 7T
Chemical exchange saturation transfer (CEST) MRI is a molecular imaging method that has previously been successful at reporting variations in tissue protein and glycogen contents and pH. We have implemented amide proton transfer (APT), a specific form of chemical exchange saturation transfer imaging, at high field (7T) and used it to study healthy human subjects and patients with multiple sclerosis. The effects of static field inhomogeneities were mitigated using a water saturation shift referencing method to center each z‐spectrum on a voxel‐by‐voxel basis. Contrary to results obtained at lower fields, APT imaging at 7T revealed significant contrast between white and gray matters, with a higher APT signal apparent within the white matter. Preliminary studies of multiple sclerosis showed that the APT asymmetry varied with the type of lesion examined. An increase in APT asymmetry relative to healthy tissue was found in some lesions. These results indicate the potential utility of APT at high field as a noninvasive biomarker of white matter pathology, providing complementary information to other MRI methods in current clinical use. Magn Reson Med, 2011.
- 22 March 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (3) , 831-838
Open AccessDevelopment of chemical exchange saturation transfer at 7T
Chemical exchange saturation transfer (CEST) MRI is a molecular imaging method that has previously been successful at reporting variations in tissue protein and glycogen contents and pH. We have implemented amide proton transfer (APT), a specific form of chemical exchange saturation transfer imaging, at high field (7T) and used it to study healthy human subjects and patients with multiple sclerosis. The effects of static field inhomogeneities were mitigated using a water saturation shift referencing method to center each z‐spectrum on a voxel‐by‐voxel basis. Contrary to results obtained at lower fields, APT imaging at 7T revealed significant contrast between white and gray matters, with a higher APT signal apparent within the white matter. Preliminary studies of multiple sclerosis showed that the APT asymmetry varied with the type of lesion examined. An increase in APT asymmetry relative to healthy tissue was found in some lesions. These results indicate the potential utility of APT at high field as a noninvasive biomarker of white matter pathology, providing complementary information to other MRI methods in current clinical use. Magn Reson Med, 2011.