David R Pennell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David R Pennell has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Adrienne N. Dula
Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
1 shared publication - David X Feng
School for Science and Math at Vanderbilt University, Vanderbilt University, Nashville, TN, USA
1 shared publication - Fea K Morgan–Curtis
School for Science and Math at Vanderbilt University, Vanderbilt University, Nashville, TN, USA
1 shared publication - Joseph P McCauley
School for Science and Math at Vanderbilt University, Vanderbilt University, Nashville, TN, USA
1 shared publication - Mary E Loveless
School for Science and Math at Vanderbilt University, Vanderbilt University, Nashville, TN, USA
1 shared publication - Redoan A Salam
School for Science and Math at Vanderbilt University, Vanderbilt University, Nashville, TN, USA
1 shared publication
Latest Publications
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150633
Evaluation of 39 medical implants at 7.0 T
Objective:With increased signal to noise ratios, 7.0-T MRI has the potential to contribute unique information regarding anatomy and pathophysiology of a disease. However, concerns for the safety of subjects with metallic medical implants have hindered advancement in this field. The purpose of the present research was to evaluate the MRI safety for 39 commonly used medical implants at 7.0 T.Methods:Selected metallic implants were tested for magnetic field interactions, radiofrequency-induced heating and artefacts using standardized testing techniques.Results:5 of the 39 implants tested may be unsafe for subjects undergoing MRI at 7.0 T.Conclusion:Implants were deemed either “MR Conditional” or “MR Unsafe” for the 7.0-T MRI environment. Further research is needed to expand the existing database categorizing implants that are acceptable for patients referred for MRI examinations at 7.0 T.Advances in knowledge:Lack of MRI testing for common metallic medical implants limits the translational potential of 7.0-T...
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150633
Evaluation of 39 medical implants at 7.0 T
Objective:With increased signal to noise ratios, 7.0-T MRI has the potential to contribute unique information regarding anatomy and pathophysiology of a disease. However, concerns for the safety of subjects with metallic medical implants have hindered advancement in this field. The purpose of the present research was to evaluate the MRI safety for 39 commonly used medical implants at 7.0 T.Methods:Selected metallic implants were tested for magnetic field interactions, radiofrequency-induced heating and artefacts using standardized testing techniques.Results:5 of the 39 implants tested may be unsafe for subjects undergoing MRI at 7.0 T.Conclusion:Implants were deemed either “MR Conditional” or “MR Unsafe” for the 7.0-T MRI environment. Further research is needed to expand the existing database categorizing implants that are acceptable for patients referred for MRI examinations at 7.0 T.Advances in knowledge:Lack of MRI testing for common metallic medical implants limits the translational potential of 7.0-T...